Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

GZMA ELISA Kit

GZMA Reaktivität: Maus Colorimetric Sandwich ELISA 3.12-200 U/mL
Produktnummer ABIN955877
  • Target Alle GZMA ELISA Kits anzeigen
    GZMA (Granzyme A (Granzyme 1, Cytotoxic T-Lymphocyte-Associated serine Esterase 3) (GZMA))
    Reaktivität
    • 5
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Maus
    Nachweismethode
    Colorimetric
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    3.12-200 U/mL
    Untere Nachweisgrenze
    3.12 U/mL
    Applikation
    ELISA
    Verwendungszweck
    The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of mouse GZM-A in serum, plasma and other biological fluids.
    Analytische Methode
    Quantitative
    Spezifität
    This assay has high sensitivity and excellent specificity for detection of mouse GZM-A. No significant cross-reactivity or interference between mouse GZM-A and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us - complete the cross-reactivity detection between mouse GZM-A and all the other analogues, therefore, cross reaction may still exist.
    Sensitivität
    The minimum detectable dose of mouse GZM-A is typically less than 0.92 U/mL.
    The Sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D. Value of 20 replicates of the zero calibrator plus three standard deviations.
    Produktmerkmale
    The microtiter plate provided in this kit has been pre-coated with an antibody specific to GZM-A. Calibrators or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for GZM-A. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB substrate solution is added to each well. Only those wells that contain GZM-A, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulfuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm +/- 10 nm. The concentration of GZM-A in the samples is then determined by comparing the O.D. of the samples to the calibration curve.
    Bestandteile
    Pre-coated, ready to use 96-well strip plate (1x)
    Calibrator (lyophilized) (2x)
    Calibrator Diluent (1 x 20 mL)
    Detection Reagent A (1 x 120 µL)
    Detection Reagent B (1 x 120 µL)
    Assay Diluent A (2X concentrate) (1 x 6 mL)
    Assay Diluent B (2X concentrate) (1 x 6 mL)
    TMB Substrate (1 x 9 mL)
    Stop Solution (1 x 6 mL)
    Wash Buffer (30X concentrate) (1 x 20 mL)
    Plate sealer for 96 wells (4x).
    Benötigtes Material
    1. Microplate reader with 450 +/- 10 nm filter.
    2. Precision single and multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. De-ionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
    Featured
    Zu unserem meistverkauften GZMA ELISA Kit
    Top Product
    Discover our top product GZMA ELISA Kit
  • Kommentare

    The calibration curve concentrations used for the ELISA's were 200 U/mL, 100 U/mL, 50 U/mL, 25 U/mL, 12.5 U/mL, 6.25 U/mL, 3.12 U/mL.

    Plattentyp
    Pre-coated
    Ergebnisberechnung

    Average the duplicate readings for each calibrator, control, and samples and subtract the average zero calibrator optical density. Create a calibration curve on log-log graph paper, with GZM-A concentration on the y-axis and absorbance on the x-axis. Draw the best fit straight line through the calibrator points and it can be determined by regression analysis. Using some plot software is also recommended. If samples have been diluted, the concentration read from the calibration curve must be multiplied by the dilution factor.

    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Lagerung
    -20 °C
    Informationen zur Lagerung
    All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20° C upon being received. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable until the expiration date shown, provided it is stored as prescribed above.
    Haltbarkeit
    The expiry date is stated on the label.
  • Target Alle GZMA ELISA Kits anzeigen
    GZMA (Granzyme A (Granzyme 1, Cytotoxic T-Lymphocyte-Associated serine Esterase 3) (GZMA))
    Andere Bezeichnung
    Granzyme A (GZM-A) (GZMA Produkte)
    Synonyme
    gzmA ELISA Kit, GZMA ELISA Kit, AW494114 ELISA Kit, Ctla-3 ELISA Kit, Ctla3 ELISA Kit, Hf ELISA Kit, SE1 ELISA Kit, TSP-1 ELISA Kit, TSP1 ELISA Kit, CTLA3 ELISA Kit, HFSP ELISA Kit, granzyme A ELISA Kit, Granzyme A ELISA Kit, granzyme A (granzyme 1, cytotoxic T-lymphocyte-associated serine esterase 3) ELISA Kit, gzmA ELISA Kit, GZMA ELISA Kit, graa ELISA Kit, Gzma ELISA Kit
    Pathways
    Apoptose
Sie sind hier:
Kundenservice