Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

AGT ELISA Kit

AGT Reaktivität: Maus Colorimetric Competition ELISA 15.625-1000 pg/mL Plasma, Serum
Produktnummer ABIN4993249
  • Target Alle AGT ELISA Kits anzeigen
    AGT (Angiotensinogen (serpin Peptidase Inhibitor, Clade A, Member 8) (AGT))
    Reaktivität
    • 9
    • 8
    • 8
    • 5
    • 3
    • 3
    • 3
    • 3
    • 2
    • 2
    • 2
    • 1
    • 1
    Maus
    Nachweismethode
    Colorimetric
    Methodentyp
    Competition ELISA
    Detektionsbereich
    15.625-1000 pg/mL
    Untere Nachweisgrenze
    15.625 pg/mL
    Applikation
    ELISA
    Verwendungszweck
    The kit is a competitive enzyme immunoassay for in vitro quantitative measurement of Ang-I in Mouse serum, plasma and other biological fluids
    Proben
    Plasma, Serum
    Analytische Methode
    Quantitative
    Spezifität
    This kit recognizes natural and recombinant Mouse Ang-I. No significant cross-reactivity or interference between Mouse Ang-I and analogues was observed. Note: Limited by existing techniques, cross reaction may still exist, as it is impossible for us to complete the cross-reactivity detection between Mouse Ang-I and all the analogues.
    Sensitivität
    9.375 pg/mL
    Bestandteile
    Micro ELISA Plate(Dismountable)
    Reference Standard
    Concentrated Biotinylated Detection Ab (100×)
    Concentrated HRP Conjugate (100×)
    Reference Standard & Sample Diluent
    Biotinylated Detection Ab Diluent
    HRP Conjugate Diluent
    Concentrated Wash Buffer (25×)
    Substrate Reagent
    Stop Solution
    Plate Sealer
    Product Description
    Certificate of Analysis
    Benötigtes Material
    Microplate reader with 450nm wavelength filter
    High-precision transferpettor, EP tubes and disposable pipette tips
    37℃ Incubator
    Deionized or distilled water
    Absorbent paper
    Loading slot for Wash Buffer
    Featured
    Zu unserem meistverkauften AGT ELISA Kit
    Top Product
    Discover our top product AGT ELISA Kit
  • Kommentare

    Information on standard material:
    The formulation of the standard is 0.01 M PBS. The standard contains additives (1 % BSA).

    Information on reagents:
    Reagents include 1 M SO2. Azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials are not used.

    Information on antibodies:
    The provided antibodies and their host vary in different kits. All antibodies are affinity purified

    The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration.

    Probenmenge
    50 µL
    Plattentyp
    Pre-coated
    Protokoll
    This ELISA kit uses Competitive-ELISA as the method. The microtiter plate provided in this kit has been pre-coated with Ang-I. During the reaction, Ang-I in the sample or standard competes with a fixed amount of Ang-I on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Ang-I. Excess conjugate and unbound sample or standard are washed from the plate, and Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spec trophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of Ang-I in the samples is then determined by comparing the OD of the samples to the standard curve. 6th Edition, revised in June, 2015 www.elabscience.com 4
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Handhabung
    All the reagents in the kit should be stored according to the labels on vials. Unused wells should be returned to the foil pouch with the desiccant pack and resealed along entire edge of zip-seal. Substrate Reagent shouldn't be kept at -20 °C (Check!). Exposure of reagents to strong light should be avoided in the process of incubation and storage. All the taps of reagents should be tightened to prevent evaporation and microbial contamination. If not to store reagents according to above suggestions, erroneous results may occur.
    Lagerung
    4 °C/-20 °C
    Informationen zur Lagerung
    The unopened kit can be stored at 4℃ for 1 month. If the kit is not used within 1 month, store the items separately according to the conditions since the kit is received.
  • Target Alle AGT ELISA Kits anzeigen
    AGT (Angiotensinogen (serpin Peptidase Inhibitor, Clade A, Member 8) (AGT))
    Andere Bezeichnung
    AngiotensinI (Ang-I) (AGT Produkte)
    Synonyme
    ANHU ELISA Kit, SERPINA8 ELISA Kit, AI265500 ELISA Kit, AngI ELISA Kit, AngII ELISA Kit, Aogen ELISA Kit, Serpina8 ELISA Kit, ANRT ELISA Kit, Ang ELISA Kit, PAT ELISA Kit, wu:fb62f06 ELISA Kit, wu:fj87b02 ELISA Kit, zgc:111892 ELISA Kit, AGT ELISA Kit, angt ELISA Kit, ANGT ELISA Kit, angiotensinogen ELISA Kit, angiotensinogen (serpin peptidase inhibitor, clade A, member 8) ELISA Kit, AGT ELISA Kit, Agt ELISA Kit, agt ELISA Kit
    Pathways
    JAK-STAT Signalweg, ACE Inhibitor Pathway, EGFR Signaling Pathway, Peptide Hormone Metabolism, Regulation of Systemic Arterial Blood Pressure by Hormones, Regulation of Lipid Metabolism by PPARalpha, Protein targeting to Nucleus, Feeding Behaviour, Monocarboxylic Acid Catabolic Process, Dicarboxylic Acid Transport, Positive Regulation of Response to DNA Damage Stimulus, Regulation of long-term Neuronal Synaptic Plasticity
Sie sind hier:
Kundenservice