TLR1 ELISA Kit

Human TLR1 ELISA-Kit Colorimetric-Assay zur Quantifizierung von Human TLR1.
Produktnummer ABIN4973428

Kurzübersicht für TLR1 ELISA Kit (ABIN4973428)

Target

Alle TLR1 ELISA Kits anzeigen
TLR1 (Toll-Like Receptor 1 (TLR1))

Reaktivität

  • 7
  • 3
Human

Nachweismethode

Colorimetric

Methodentyp

Sandwich ELISA

Detektionsbereich

0.312 ng/mL - 20 ng/mL

Applikation

ELISA

Proben

Cell Lysate, Tissue Homogenate
  • Untere Nachweisgrenze

    0.312 ng/mL

    Verwendungszweck

    Human Toll Like Receptor 1 (TLR1) ELISA Kit

    Analytische Methode

    Quantitative

    Sensitivität

    0.19 ng/mL

    Bestandteile

    The kit components listed are for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
    • Pre-coated 96-Well Microplate
    • Standard
    • Standard Diluent Buffer
    • Wash Buffer
    • Detection Reagent A
    • Detection Reagent B
    • Diluent A
    • Diluent B
    • TMB Substrate
    • Stop Solution
    • Plate Sealer

    Benötigtes Material

    • 37 °C incubator
    • Multi and single channel pipettes and sterile pipette tips
    • Squirt bottle or automated microplate washer
    • 1.5 mL tubes
    • Distilled water
    • Absorbent filter papers
    • 100 mL and 1 liter graduated cylinders
    • Microplate reader (wavelength: 450 nm)
    • ELISA Shaker
  • Applikationshinweise

    Optimal dilutions/concentrations should be determined by the end user.

    Kommentare

    The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5 % within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.

    Plattentyp

    Pre-coated

    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, medium and high levels of Toll Like Receptor 1 (TLR1) were tested 20 times on one plate, respectively.

    Inter-assay Precision (Precision between assays): 3 samples with low, medium and high levels of Toll Like Receptor 1 (TLR1) were tested on 3 different plates, 8 replicates in each plate.

    CV (%) = (Standard Deviation / mean) x 100

    Intra-Assay: CV<10%

    Inter-Assay: CV<10%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Lagerung

    4 °C

    Informationen zur Lagerung

    Shipped at 4 °C. Upon receipt, store the kit according to the storage instruction in the kit's manual.

    Haltbarkeit

    6 months
  • Target Alle TLR1 ELISA Kits anzeigen

    TLR1 (Toll-Like Receptor 1 (TLR1))

    Andere Bezeichnung

    Toll Like Receptor 1

    Hintergrund

    Ensembl: ENSG00000174125

    UniProt Entry Name: TLR1_HUMAN

    Gen-ID

    7096

    HGNC

    11847

    OMIM

    601194

    UniProt

    Q15399

    Pathways

    TLR Signalweg, Activation of Innate immune Response, Cellular Response to Molecule of Bacterial Origin, Toll-Like Receptors Cascades