IL12A ELISA Kit (Interleukin 12 alpha)

Details for Product IL12A ELISA Kit No. ABIN1570604, Anbieter: Anmelden zum Anzeigen
Antigen
  • IL-12p35
  • Il-12a
  • Ll12a
  • p35
  • CLMF
  • IL-12A
  • NFSK
  • NKSF1
  • P35
  • IL12p35
  • Il-12 p35
  • IL12
  • interleukin 12a
  • interleukin 12A
  • Il12a
  • IL12A
Reaktivität
Ratte (Rattus)
Alternativen
Kits mit alternativen Reaktivitäten:
13
8
7
6
5
5
3
3
2
2
2
1
1
1
Methodentyp
Sandwich ELISA
Detektionsbereich
15.625-1000 pg/mL
Untere Nachweisgrenze
15.625 pg/mL
Applikation
ELISA
Optionen
Hersteller
Anmelden zum Anzeigen
Hersteller Produkt- Nr.
Anmelden zum Anzeigen
Verwendungszweck The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of IL12A in rat serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
Proben Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
Analytische Methode Quantitative
Nachweismethode Colorimetric
Spezifität This assay has high sensitivity and excellent specificity for detection of this index.
Kreuzreaktivität (Details) No significant cross-reactivity or interference between this index and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross- reactivity detection between this index and all the analogues, therefore, cross reaction may still exist.
Sensitivität 6.1 pg/mL
Bestandteile
  • Pre-coated, ready to use 96-well strip plate
  • Standard (freeze dried)
  • Standard Diluent
  • Detection Reagent A
  • Detection Reagent B
  • Assay Diluent A
  • Assay Diluent B
  • TMB
  • Stop Solution
  • Wash Buffer (30X)
  • Plate sealer for 96 wells
  • Instruction manual
Benötigtes Material
  1. Microplate reader with 450 ± 10nm filter.
  2. Precision single or multi-channel pipettes and disposable tips.
  3. Eppendorf Tubes for diluting samples.
  4. Deionized or distilled water.
  5. Absorbent paper for blotting the microtiter plate.
  6. Container for Wash Solution.
Andere Bezeichnung IL12A (IL12A ELISA Kit Abstract)
Hintergrund Synonyms: CLMF p35,Cytotoxic lymphocyte maturation factor 35 kDa subunit,IL-12 subunit p35,Il12a,IL-12A,Interleukin-12 subunit alpha
Gen-ID 84405
UniProt Q9R278
Pathways JAK-STAT Signalweg, Regulation of Leukocyte Mediated Immunity, Positive Regulation of Immune Effector Process, Activated T Cell Proliferation
Probenmenge 100 μL
Testdauer 1 - 4.5 h
Plattentyp Pre-coated
Protokoll 1. Prepare all reagents, samples and standards
2. Add 100 µL standard or sample to each well. Incubate 2 hours at 37 °C
3. Aspirate and add 100 µL prepared Detection Reagent A. Incubate 1 hour at 37 °C
4. Aspirate and wash 3 times
5. Add 100 µL prepared Detection Reagent B. Incubate 30 minutes at 37 °C
6. Aspirate and wash 5 times
7. Add 90 µL Substrate Solution. Incubate 15-25 minutes at 37 °C
8. Add 50 µL Stop Solution. Read at 450nm immediately.
Testdurchführung

The microtiter plate provided in this kit has been pre-coated with an antibody specific to the index. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific to the index. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain the index, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of the index in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Testpräzision
  • Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
  • Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
  • CV(%) = SD/meanX100
  • Intra-assay: CV<10%
  • Inter-assay: CV<12%
Beschränkungen Nur für Forschungszwecke einsetzbar
Vorsichtsmaßnahmen The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
Handhabung The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Lagerung 4 °C,-20 °C
Haltbarkeit 12 months
Bilder des Herstellers
ELISA image for Interleukin 12 alpha (IL12A) ELISA Kit (ABIN1570604) Typical Standard Curve
Haben Sie etwas anderes gesucht?