IL-2 ELISA Kit

Dieses Colorimetric ELISA kit dient der quantitativen Messung von Kaninchen IL-2.
Produktnummer ABIN955904
1.623,00 €
Zzgl. Versandkosten 20,00 € und MwSt
96 tests
Lieferung nach: Deutschland
Lieferung in 15 bis 22 Werktagen

Kurzübersicht für IL-2 ELISA Kit (ABIN955904)

Target

Alle IL-2 (IL2) ELISA Kits anzeigen
IL-2 (IL2) (Interleukin 2 (IL2))

Reaktivität

  • 25
  • 21
  • 18
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
Kaninchen

Nachweismethode

Colorimetric

Methodentyp

Sandwich ELISA

Detektionsbereich

15.6-1000 pg/mL

Applikation

ELISA
  • Untere Nachweisgrenze

    15.6 pg/mL

    Verwendungszweck

    The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of rabbit IL2 in serum, plasma, tissue homogenates, cell culture supernates and other biological fluids.

    Analytische Methode

    Quantitative

    Spezifität

    This assay has high sensitivity and excellent specificity for detection of rabbit IL2. No significant cross- reactivity or interference between rabbit IL2 and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us - complete the cross-reactivity detection between rabbit IL2 and all the analogues, therefore, cross reaction may still exist.

    Sensitivität

    The minimum detectable dose of rabbit IL2 is typically less than 5.1 pg/mL.
    The Sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations - the mean optical density value of twenty zero calibrator replicates and calculating the corresponding concentration.

    Produktmerkmale

    The microtiter plate provided in this kit has been pre-coated with an antibody specific to IL2. Calibrators or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific for IL2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain IL2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulfuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm +/- 10 nm. The concentration of IL2 in the samples is then determined by comparing the O.D. of the samples to the calibration curve.

    Bestandteile

    Pre-coated, ready to use 96-well strip plate (1x)
    Calibrator (lyophilized) (2x)
    Calibrator Diluent (1 x 20 mL)
    Detection Reagent A (1 x 120 µL)
    Detection Reagent B (1 x 120 µL)
    Assay Diluent A (2X concentrate) (1 x 6 mL)
    Assay Diluent B (2X concentrate) (1 x 6 mL)
    TMB Substrate (1 x 9 mL)
    Stop Solution (1 x 6 mL)
    Wash Buffer (30X concentrate) (1 x 20 mL)
    Plate sealer for 96 wells (4x).

    Benötigtes Material

    1. Microplate reader with 450 +/- 10 nm filter.
    2. Precision single or multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. Deionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution
  • Kommentare

    The calibration curve concentrations used for the ELISA's were 1000 pg/mL, 500 pg/mL, 250 pg/mL, 125 pg/mL, 62.5 pg/mL, 31.2 pg/mL, 15.6 pg/mL.

    Plattentyp

    Pre-coated

    Ergebnisberechnung

    Average the duplicate readings for each calibrator, control, and samples and subtract the average zero calibrator optical density. Create a calibration curve on log-log graph paper, with IL2 concentration on the y-axis and absorbance on the x-axis. Draw the best fit straight line through the calibrator points and it can be determined by regression analysis. Using some plot software is also recommended. If samples have been diluted, the concentration read from the calibration curve must be multiplied by the dilution factor.

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Lagerung

    -20 °C

    Informationen zur Lagerung

    All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20° C upon being received. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable until the expiration date shown, provided it is stored as prescribed above.

    Haltbarkeit

    The expiry date is stated on the label.
  • Target Alle IL-2 (IL2) ELISA Kits anzeigen

    IL-2 (IL2) (Interleukin 2 (IL2))

    Andere Bezeichnung

    IL2

    Pathways

    JAK-STAT Signalweg, Regulation of Leukocyte Mediated Immunity, Positive Regulation of Immune Effector Process, Production of Molecular Mediator of Immune Response, Activated T Cell Proliferation