Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

ATG5 ELISA Kit

Ratte ATG5 ELISA-Kit Colorimetric-Assay zur Quantifizierung von Ratte ATG5.
Produktnummer ABIN6226376

Kurzübersicht für ATG5 ELISA Kit (ABIN6226376)

Target

Alle ATG5 ELISA Kits anzeigen
ATG5 (ATG5 Autophagy Related 5 (ATG5))

Reaktivität

  • 5
  • 2
  • 1
  • 1
  • 1
Ratte

Nachweismethode

Colorimetric

Methodentyp

Sandwich ELISA

Detektionsbereich

0.156 ng/mL - 10 ng/mL

Applikation

ELISA

Proben

Cell Lysate, Tissue Homogenate
  • Untere Nachweisgrenze

    0.156 ng/mL

    Verwendungszweck

    Rat Autophagy Protein 5 (ATG5) ELISA Kit

    Analytische Methode

    Quantitative

    Sensitivität

    < 0.055 ng/mL

    Bestandteile

    The kit components listed are for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
    • Pre-coated 96-Well Microplate
    • Standard
    • Standard Diluent Buffer
    • Wash Buffer
    • Detection Reagent A
    • Detection Reagent B
    • Diluent A
    • Diluent B
    • TMB Substrate
    • Stop Solution
    • Plate Sealer

    Benötigtes Material

    • 37 °C incubator
    • Multi and single channel pipettes and sterile pipette tips
    • Squirt bottle or automated microplate washer
    • 1.5 mL tubes
    • Distilled water
    • Absorbent filter papers
    • 100 mL and 1 liter graduated cylinders
    • Microplate reader (wavelength: 450 nm)
    • ELISA Shaker
  • Applikationshinweise

    Optimal dilutions/concentrations should be determined by the end user.

    Kommentare

    The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5 % within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.

    Probenmenge

    100 µL

    Plattentyp

    Pre-coated

    Aufbereitung der Reagenzien

    This procedure is provided for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.

    • 1) Standard: Prepare the standard with the recommended volume of Standard Diluent Buffer, to make the standard solution. Then use the Standard Diluent buffer to carry out serial dilutions of the standard solution, as instructed in the Protocol.
    • 2) Wash Buffer: Dilute the concentrated Wash Buffer with distilled water, as instructed in the Protocol.
    • 3) Detection Reagent Preparation: Calculate the total volume of working solution required. Dilute Detection Reagent A and Detection Reagent B with Diluent A and Diluent B, respectively, at 1:100.

    Testdurchführung

    This procedure is provided for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.

    • Equilibrate the kit components and samples to room temperature (18 - 25 °C) before use. It is recommended to plot a standard curve for each test.
    • 1. Set standard, test sample and control (zero) wells on the pre-coated plate respectively, and then, record their positions. It is recommended to measure each standard and sample at least in duplicate.
    • 2. Add 100 μL of each standard, control and sample into the appropriate wells. Seal the plate with a cover and incubate for 1 h at 37 °C.
    • 3. Remove the cover and discard the liquid.
    • 4. Add 100 μL of the detection Reagent A working solution to each well. Seal the plate with a cover and incubate for 1 h at 37 °C.
    • 5. Remove the cover and discard the solution. Wash the plate 3 times with 1X Wash Buffer.
    • 6. Add 100 μL of Detection Reagent B working solution into each well, seal and incubate at 37 °C for 30 min.
    • 7. Discard the solution and wash the plate 5 times with wash buffer as explained in previous step.
    • 8. Aliquot 90 μL of TMB Substrate into each well. Seal the plate with a cover and incubate at 37 °C for 10-20 min. Avoid exposure to light. The incubation time is for reference use only, the optimal time should be determined by end user. Do not exceed 30 min.
    • 9. Add 50 μL of Stop Solution to each well. Read at 450 nm immediately.

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Lagerung

    4 °C

    Informationen zur Lagerung

    Shipped at 4 °C. Upon receipt, store the kit according to the storage instruction in the kit's manual.

    Haltbarkeit

    6 months
  • Target Alle ATG5 ELISA Kits anzeigen

    ATG5 (ATG5 Autophagy Related 5 (ATG5))

    Andere Bezeichnung

    Autophagy Protein 5

    Pathways

    Activation of Innate immune Response, Production of Molecular Mediator of Immune Response, Autophagie
Sie sind hier:
Chat with us!