Das Human Gelsolin ELISA Kit (ABIN955872) ist ein Colorimetric ELISA Kit zur Detektion von Human Gelsolin.
Produktnummer ABIN955872
1.503,00 €
Zzgl. Versandkosten 20,00 € und MwSt
96 tests
Lieferung nach: Deutschland
Lieferung in 15 bis 22 Werktagen

Kurzübersicht für Gelsolin ELISA Kit (ABIN955872)

Target

Alle Gelsolin (GSN) ELISA Kits anzeigen
Gelsolin (GSN)

Reaktivität

  • 6
  • 5
  • 5
  • 4
  • 4
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
Human

Nachweismethode

Colorimetric

Methodentyp

Sandwich ELISA

Detektionsbereich

3.9-250 ng/mL

Applikation

ELISA
  • Untere Nachweisgrenze

    3.9 ng/mL

    Verwendungszweck

    The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of human GS in serum, plasma, tissue homogenates, cell culture supernates and other biological fluids.

    Analytische Methode

    Quantitative

    Spezifität

    This assay has high sensitivity and excellent specificity for detection of human GS. No significant cross- reactivity or interference between human GS and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us - complete the cross-reactivity detection between human GS and all the other analogues, therefore, cross reaction may still exist.

    Sensitivität

    The minimum detectable dose of human GS is typically less than 1.5 ng/mL.
    The Sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D. Value of 20 replicates of the zero calibrator plus three standard deviations.

    Produktmerkmale

    The microtiter plate provided in this kit has been pre-coated with an antibody specific to GS. Calibrators or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for GS. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB substrate solution is added to each well. Only those wells that contain GS, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulfuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm +/- 10 nm. The concentration of GS in the samples is then determined by comparing the O.D. of the samples to the calibration curve.

    Bestandteile

    Pre-coated, ready to use 96-well strip plate (1x)
    Calibrator (lyophilized) (2x)
    Calibrator Diluent (1 x 20 mL)
    Detection Reagent A (1 x 120 µL)
    Detection Reagent B (1 x 120 µL)
    Assay Diluent A (2X concentrate) (1 x 6 mL)
    Assay Diluent B (2X concentrate) (1 x 6 mL)
    TMB Substrate (1 x 9 mL)
    Stop Solution (1 x 6 mL)
    Wash Buffer (30X concentrate) (1 x 20 mL)
    Plate sealer for 96 wells (4x).

    Benötigtes Material

    1. Microplate reader with 450 +/- 10 nm filter.
    2. Precision single and multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. De-ionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
  • Kommentare

    The calibration curve concentrations used for the ELISA's were 250 ng/mL, 125 ng/mL, 62.5 ng/mL, 31.2 ng/mL, 15.6 ng/mL, 7.8 ng/mL, 3.9 ng/mL.

    Plattentyp

    Pre-coated

    Ergebnisberechnung

    Average the duplicate readings for each calibrator, control, and samples and subtract the average zero calibrator optical density. Create a calibration curve on log-log graph paper, with GS concentration on the y-axis and absorbance on the x-axis. Draw the best fit straight line through the calibrator points and it can be determined by regression analysis. Using some plot software is also recommended. If samples have been diluted, the concentration read from the calibration curve must be multiplied by the dilution factor.

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Lagerung

    -20 °C

    Informationen zur Lagerung

    All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20° C upon being received. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable until the expiration date shown, provided it is stored as prescribed above.

    Haltbarkeit

    The expiry date is stated on the label.
  • Target Alle Gelsolin (GSN) ELISA Kits anzeigen

    Gelsolin (GSN)

    Andere Bezeichnung

    Gelsolin (GS)

    Pathways

    Caspase Kaskade in der Apoptose, Regulation of Actin Filament Polymerization, Autophagie
Sie sind hier:
Blank Blank Blank Blank
Blank Blank Blank Blank
Chat with us!