Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

Complement Factor H ELISA Kit

CFH Reaktivität: Maus Colorimetric Sandwich ELISA 15.6-1000 ng/mL
Produktnummer ABIN955832
  • Target Alle Complement Factor H (CFH) ELISA Kits anzeigen
    Complement Factor H (CFH)
    Reaktivität
    • 7
    • 7
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Maus
    Nachweismethode
    Colorimetric
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    15.6-1000 ng/mL
    Untere Nachweisgrenze
    15.6 ng/mL
    Applikation
    ELISA
    Verwendungszweck
    The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of mouse CF-H in serum, plasma and other biological fluids.
    Analytische Methode
    Quantitative
    Spezifität
    This assay has high sensitivity and excellent specificity for detection of mouse CF-H. No significant cross- reactivity or interference was observed.
    Sensitivität
    The minimum detectable dose of mouse CF-H is typically less than 6.7 ng/mL.
    The Sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D. Value of 20 replicates of the zero calibrator plus three standard deviations.
    Produktmerkmale
    The microtiter plate provided in this kit has been pre-coated with an antibody specific to CF-H. Calibrators or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for CF-H. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB substrate solution is added to each well. Only those wells that contain CF-H, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulfuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm +/- 2 nm. The concentration of CF-H in the samples is then determined by comparing the O.D. of the samples to the calibration curve.
    Bestandteile
    Pre-coated, ready to use 96-well strip plate (1x)
    Calibrator (lyophilized) (2x)
    Calibrator Diluent (1 x 20 mL)
    Detection Reagent A (1 x 120 µL)
    Detection Reagent B (1 x 120 µL)
    Assay Diluent A (2X concentrate) (1 x 6 mL)
    Assay Diluent B (2X concentrate) (1 x 6 mL)
    TMB Substrate (1 x 9 mL)
    Stop Solution (1 x 6 mL)
    Wash Buffer (30X concentrate) (1 x 20 mL)
    Plate sealer for 96 wells (4x).
    Benötigtes Material
    1. Microplate reader with 450 +/- 10 nm filter.
    2. Precision single and multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. De-ionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
    Featured
    Zu unserem meistverkauften CFH ELISA Kit
    Top Product
    Discover our top product CFH ELISA Kit
  • Kommentare

    The calibration curve concentrations used for the ELISA's were 1000 ng/mL, 500 ng/mL, 250 ng/mL, 125 ng/mL, 62.5 ng/mL, 31.2 ng/mL, 15.6 ng/mL.

    Plattentyp
    Pre-coated
    Ergebnisberechnung

    Average the duplicate readings for each calibrator, control, and samples and subtract the average zero calibrator optical density. Create a calibration curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a calibration curve by plotting the mean absorbance for each calibrator on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the CF-H concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. It is recommended to use some related software to do this calculation. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the calibration curve must be multiplied by the dilution factor.

    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Lagerung
    -20 °C
    Informationen zur Lagerung
    All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20° C upon being received. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable until the expiration date shown, provided it is stored as prescribed above.
    Haltbarkeit
    The expiry date is stated on the label.
  • Target Alle Complement Factor H (CFH) ELISA Kits anzeigen
    Complement Factor H (CFH)
    Andere Bezeichnung
    Complement Factor H (CF-H) (CFH Produkte)
    Synonyme
    AHUS1 ELISA Kit, AMBP1 ELISA Kit, ARMD4 ELISA Kit, ARMS1 ELISA Kit, CFHL3 ELISA Kit, FH ELISA Kit, FHL1 ELISA Kit, HF ELISA Kit, HF1 ELISA Kit, HF2 ELISA Kit, HUS ELISA Kit, Mud-1 ELISA Kit, NOM ELISA Kit, Sas-1 ELISA Kit, Sas1 ELISA Kit, Fh ELISA Kit, CFH ELISA Kit, im:7147412 ELISA Kit, si:ch211-207o17.2 ELISA Kit, fH ELISA Kit, armd4 ELISA Kit, arms1 ELISA Kit, cfh ELISA Kit, cfhl3 ELISA Kit, fhl1 ELISA Kit, hf1 ELISA Kit, hf2 ELISA Kit, hus ELISA Kit, complement factor H ELISA Kit, complement component factor h ELISA Kit, complement factor H-related protein 5 ELISA Kit, complement factor H L homeolog ELISA Kit, CFH ELISA Kit, Cfh ELISA Kit, cfh ELISA Kit, LOC100399888 ELISA Kit, LOC100733902 ELISA Kit, cfh.L ELISA Kit
    Pathways
    Komplementsystem, Cellular Response to Molecule of Bacterial Origin
Sie sind hier:
Kundenservice