Angiotensin I Converting Enzyme 1 ELISA Kit

Dieses Colorimetric ELISA kit dient der quantitativen Messung von Ratte Angiotensin I Converting Enzyme 1.
Produktnummer ABIN7670859
641,23 €
Zzgl. Versandkosten 20,00 € und MwSt
96 tests
Lieferung nach: Deutschland
Lieferung in 11 bis 15 Werktagen

Kurzübersicht für Angiotensin I Converting Enzyme 1 ELISA Kit (ABIN7670859)

Target

Alle Angiotensin I Converting Enzyme 1 (ACE) ELISA Kits anzeigen
Angiotensin I Converting Enzyme 1 (ACE) (Angiotensin I Converting Enzyme (Peptidyl-Dipeptidase A) 1 (ACE))

Reaktivität

  • 30
  • 24
  • 16
  • 8
  • 5
  • 5
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
Ratte

Nachweismethode

Colorimetric

Methodentyp

Sandwich ELISA

Detektionsbereich

0.313 ng/mL - 20 ng/mL

Applikation

ELISA

Proben

Biological Fluids, Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Lysate

Güteklasse

Quick
  • Untere Nachweisgrenze

    0.313 ng/mL

    Verwendungszweck

    Rat Ace (Angiotensin-converting enzyme) QuickTest ELISA Kit

    Analytische Methode

    Quantitative

    Spezifität

    Specifically binds with Ace , no obvious cross reaction with other analogues.

    Sensitivität

    0.188 ng/mL

    Bestandteile

    • ELISA Microplate(Dismountable)
    • Lyophilized Standard
    • Cap/Det Ab (Ready to use
    • blue)
    • TMB Substrate
    • Sample Dilution Buffer
    • Stop Solution
    • Plate Sealer
    • Product Description

    Benötigtes Material

    • Microplate reader (wavelength: 450nm)
    • 37 °C incubator (CO2 incubator for cell culture is not recommenced.)
    • Automated plate washer or multi-channel pipette/5 mL pipettor
    • Precision single (0.5-10μL
    • 5-50μL
    • 20-200μL
    • 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
    • Sterile tubes and Eppendorf tubes with disposable tips
    • Absorbent paper and loading slot
    • Deionized or distilled water
  • Applikationshinweise

    Optimal working dilution should be determined by the investigator.

    Kommentare

    Sandwich ELISA, Double Antibody

    Probenmenge

    50 μL

    Testdauer

    2 h

    Plattentyp

    Pre-coated

    Protokoll

    Step 1: Take out the required plate wells, add 50 µL Cap/Det Ab into each well, then add 50 µL Standard or Sample into individual well. (When adding standard or sample, the disposable tip lightly touches the liquid level. Change the disposable tips for different samples and standards.) Gently tap the plate for 10s to ensure thorough mixing then static incubate for 60 minutes at 37 °C. Washing: Wash the plate twice without immersion. Step 2: Add 100 µL HRP-Streptavidin (orange) into each well, seal the plate and static incubate for 30 minutes at 37 °C. Washing: Wash the plate five times without immersion. Step 3: Add 90 µL TMB substrate solution, seal the plate and static incubate for 10-20 minutes at 37 °C. (Accurate TMB visualization control is required.) Step 4: Add 50 µL stop solution. Read at 450nm immediately and calculate.

    Testdurchführung

    1. Take out the required strips, add 50 µL Cap/Det Ab into each well, then add 50 µL Standard or Sample into relevant well. (When adding standard or sample, the disposable tip lightly touches the liquid level. Change the disposable tips for different samples and standards.) Gently tap the plate for 10s to ensure complete mixing then statically incubate for 60 minutes at 37 °C.
    2. Wash the plate twice without immersion.
    3. Add 100 µL HRP-Streptavidin (orange) into each well, seal the plate and statically incubate for 30 minutes at 37 °C.
    4. Wash the plate five times without immersion.
    5. Add 90 µL TMB substrate solution, seal the plate and statically incubate for 10-20 minutes at 37 °C (Accurate TMB visualization control is required.).
    6. Add 50 µL stop solution. Read at 450nm immediately and calculate.

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Handhabung

    Avoid direct light exposure to antibody solutions

    Lagerung

    4 °C

    Informationen zur Lagerung

    Store sealed Kit at 2-8° C. Do Not Cryopreserve. Store ELISA Microplate for 1 month at 2-8°C, Store for 12 month at -20°C. Put the leftover strips into a sealed foil bag with the desiccant

    Haltbarkeit

    12 months
  • Target Alle Angiotensin I Converting Enzyme 1 (ACE) ELISA Kits anzeigen

    Angiotensin I Converting Enzyme 1 (ACE) (Angiotensin I Converting Enzyme (Peptidyl-Dipeptidase A) 1 (ACE))

    Andere Bezeichnung

    Ace

    Hintergrund

    Angiotensin-converting enzyme, ACE, Dipeptidyl carboxypeptidase I, Kininase II, Angiotensin-converting enzyme, soluble form, ACE, DCP, DCP1

    UniProt

    P47820

    Pathways

    ACE Inhibitor Pathway, Peptide Hormone Metabolism, Regulation of Systemic Arterial Blood Pressure by Hormones, Feeding Behaviour, Smooth Muscle Cell Migration