LIFR ELISA Kit
Kurzübersicht für LIFR ELISA Kit (ABIN6719764)
Target
Alle LIFR ELISA Kits anzeigenReaktivität
Nachweismethode
Methodentyp
Detektionsbereich
Applikation
Proben
-
-
Untere Nachweisgrenze
- 156 pg/mL
-
Hersteller Produkt- Nr.
- koa0697
-
Hersteller
- Rockland
-
Verwendungszweck
- Human LIFR Sandwich ELISA Kit for Quantitative Detection
-
Marke
- AccuSignal™
-
Analytische Methode
- Quantitative
-
Spezifität
-
Expression system for standard: NS0
Immunogen sequence: Q45-S833 -
Kreuzreaktivität (Details)
- There is no detectable cross-reactivity with other relevant proteins.
-
Sensitivität
- < 10 pg/mL
-
Bestandteile
-
- Antibody-coated 96-well plate
- Target Protein Standard
- Detection antibody
- Detection reagent
- Diluent buffers
- Wash buffers
- Substrate Solution
- Stop solutions
- Adhesive covers
-
Benötigtes Material
- Microplate Reader capable of reading absorbance at 450nm. Incubator. Automated plate washer (optional). Pipettes and pipette tips capable of precisely dispensing 0.5 μL through 1 mL volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500 mL graduated cylinders. Test tubes for dilution.
-
-
-
-
Kommentare
-
Capture antibody and Detection antibody: polyclonal antibody from goat, polyclonal antibody from goat
-
Probenmenge
- 100 μL
-
Plattentyp
- Pre-coated
-
Protokoll
- Useful in Sandwich ELISA for Quantitative Detection of Antigen. Aliquot 0.1 mL per well of the 10,000pg/mL, 5000pg/mL, 2500pg/mL, 1250pg/mL, 625pg/mL, 312pg/mL, 156pg/mL human LIFR standard solutions into the precoated 96-well plate. Add 0.1 mL of the sample diluent buffer into the control well (Zero well). Add 0.1 mL of each properly diluted sample of human cell culture supernates, serum or plasma(heparin, EDTA) to each empty well. It is recommended that each human LIFR standard solution and each sample be measured in duplicate.
-
Testpräzision
-
Intra-Assay Precision (CV%): 5.8%, 4.9%, 4.3%
Inter-Assay Precision (CV%): 6.4%, 6.1%, 6.2% -
Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
-
-
Lagerung
- 4 °C,-20 °C
-
Informationen zur Lagerung
- Store vials at 4°C prior to opening. Centrifuge product if not completely clear after standing at room temperature. This product is stable for 6 months at 4°C as an undiluted liquid. Dilute only prior to immediate use. For extended storage freeze at -20°C or below for 12 months. Avoid cycles of freezing and thawing.
-
Haltbarkeit
- 12 months
-
-
- LIFR (Leukemia Inhibitory Factor Receptor alpha (LIFR))
-
Andere Bezeichnung
- LIFR
-
Hintergrund
-
Background: LIFR, also known as CD118 (Cluster of Differentiation 118), is a subunit of a receptor for leukemia inhibitory factor. This gene encodes a protein that belongs to the type I cytokine receptor family. It is mapped to 5p31.1. The LIF receptor (LIFR) is the low-affinity binding chain that, together with the high-affinity converter subunit gp130, forms a high-affinity receptor complex that mediates the action of the leukemia-inhibitory factor. LIF is a polyfunctional cytokine that affects the differentiation, survival, and proliferation of a wide variety of cells in the adult and the embryo. Mutations in this gene cause Schwartz-Jampel syndrome type 2, a disease belonging to the group of the bent-bone dysplasias. A translocation that involves the promoter of this gene, togerther with the pleiomorphic adenoma gene 1, is associated with salivary gland pleiomorphic adenoma, a common type of benign epithelial tumor of the salivary gland.
Gene Full Name: LIF receptor subunit alpha
-
Gen-ID
- 3977
-
NCBI Accession
- NP_001121143
-
UniProt
- P42702
-
Pathways
- JAK-STAT Signalweg, Growth Factor Binding
Target Alle LIFR ELISA Kits anzeigen
-