Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

Oncostatin M CLIA Kit

Human Oncostatin M ELISA Kit, Chemiluminescent Assay für die Quantifizierung von Human Oncostatin M.
Produktnummer ABIN5657501
1.260,69 €
Zzgl. Versandkosten 20,00 € und MwSt
96 tests
Lieferung nach: Deutschland
Lieferung in 12 bis 18 Werktagen

Kurzübersicht für Oncostatin M CLIA Kit (ABIN5657501)

Target

Alle Oncostatin M (OSM) CLIA Kits anzeigen
Oncostatin M (OSM)

Reaktivität

  • 13
  • 12
  • 6
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Human

Nachweismethode

Chemiluminescent

Methodentyp

Sandwich ELISA

Detektionsbereich

31.25 pg/mL - 2000 pg/mL

Applikation

ELISA

Proben

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
  • Untere Nachweisgrenze

    31.25 pg/mL

    Analytische Methode

    Quantitative

    Spezifität

    This assay has high sensitivity and excellent specificity for detection of Oncostatin M (OSM). No significant cross-reactivity or interference between Oncostatin M (OSM) and analogues was observed.

    Sensitivität

    0.93 pg/mL
  • Kommentare

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Testdauer

    2 - 3 h

    Plattentyp

    Pre-coated

    Protokoll

    The microplate provided in this kit has been pre-coated with an antibody specific to Oncostatin M (OSM). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Oncostatin M (OSM). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Oncostatin M (OSM) level in the sample or standard.,

    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Oncostatin M (OSM) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Oncostatin M (OSM) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Handhabung

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Lagerung

    4 °C,-20 °C

    Informationen zur Lagerung

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Haltbarkeit

    4-8 months
  • Target Alle Oncostatin M (OSM) CLIA Kits anzeigen

    Oncostatin M (OSM)

    Andere Bezeichnung

    Oncostatin M

    Hintergrund

    Gene Name: Oncostatin M

    Gene Aliases: OS-M

    Gen-ID

    5008

    UniProt

    P13725

    Pathways

    JAK-STAT Signalweg, Negative Regulation of Hormone Secretion
Sie sind hier:
Chat with us!