Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

FSH CLIA Kit

Das Ratte FSH ELISA Kit (ABIN5654389) ist ein Chemiluminescent ELISA Kit zur Detektion von Ratte FSH.
Produktnummer ABIN5654389
1.355,31 €
Zzgl. Versandkosten 20,00 € und MwSt
96 tests
Lieferung nach: Deutschland
Lieferung in 12 bis 18 Werktagen

Kurzübersicht für FSH CLIA Kit (ABIN5654389)

Target

Alle FSH CLIA Kits anzeigen
FSH (Follicle-Stimulating Hormone (FSH))

Reaktivität

  • 24
  • 20
  • 15
  • 12
  • 12
  • 10
  • 9
  • 8
  • 8
  • 8
  • 7
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
Ratte

Nachweismethode

Chemiluminescent

Methodentyp

Competition ELISA

Detektionsbereich

1.56 ng/mL - 400 ng/mL

Applikation

ELISA

Proben

Plasma, Serum
  • Untere Nachweisgrenze

    1.56 ng/mL

    Verwendungszweck

    Rat Follicle Stimulating Hormone (FSH) CLIA Kit for detecting FSH in serum, plasma

    Analytische Methode

    Quantitative

    Spezifität

    This assay has high sensitivity and excellent specificity for detection of Follicle Stimulating Hormone (FSH). No significant cross-reactivity or interference between Follicle Stimulating Hormone (FSH) and analogues was observed.

    Sensitivität

    0.58 ng/mL

    Bestandteile

    • Pre-coated, ready to use 96-well strip plate
    • Standar
    • Detection Reagent A
    • Detection Reagent B
    • Substrate A
    • Substrate B
    • Assay Diluent A
    • Assay Diluent B
    • Wash Buffer (30x concentrate)
    • Standard Diluent
    • Plate Sealer
    • Instruction Manual

    Benötigtes Material

    • Microplate Reader with 450 nm filter
    • Single or multi-channel pipettes with high precision and disposable tips
    • Microcentrifuge tubes
    • Deionized or distilled watter
    • Absorbent paper for blotting the microplate
    • Container for wash solution
    • 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
  • Applikationshinweise

    Optimal working dilution should be determined by the investigator.

    Kommentare

    This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.

    Probenmenge

    50 μL

    Testdauer

    2 h

    Plattentyp

    Pre-coated

    Protokoll

    The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Follicle Stimulating Hormone (FSH). A competitive inhibition reaction is launched between biotin labeled Follicle Stimulating Hormone (FSH) and unlabeled Follicle Stimulating Hormone (FSH) (Standards or samples) with the pre-coated antibody specific to Follicle Stimulating Hormone (FSH). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Follicle Stimulating Hormone (FSH) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Follicle Stimulating Hormone (FSH) level in the sample or standard.

    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Follicle Stimulating Hormone (FSH) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Follicle Stimulating Hormone (FSH) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Handhabung

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Lagerung

    4 °C,-20 °C

    Informationen zur Lagerung

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Haltbarkeit

    12 months
  • Target Alle FSH CLIA Kits anzeigen

    FSH (Follicle-Stimulating Hormone (FSH))

    Andere Bezeichnung

    Follicle Stimulating Hormone

    Substanzklasse

    Hormone

    Hintergrund

    Gene Aliases:

    Gen-ID

    116700

    UniProt

    P11962

    Pathways

    Peptide Hormone Metabolism, Chromatin Binding
Sie sind hier: