Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

Cathepsin D CLIA Kit

Maus Cathepsin D ELISA Kit, Chemiluminescent Assay für die Quantifizierung von Maus Cathepsin D.
Produktnummer ABIN5652698
1.291,85 €
Zzgl. Versandkosten 20,00 € und MwSt
96 tests
Lieferung nach: Deutschland
Lieferung in 12 bis 18 Werktagen

Kurzübersicht für Cathepsin D CLIA Kit (ABIN5652698)

Target

Alle Cathepsin D (CTSD) CLIA Kits anzeigen
Cathepsin D (CTSD)

Reaktivität

  • 15
  • 12
  • 6
  • 6
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
Maus

Nachweismethode

Chemiluminescent

Methodentyp

Sandwich ELISA

Detektionsbereich

31.25 pg/mL - 2000 pg/mL

Applikation

ELISA

Proben

Plasma, Serum
  • Untere Nachweisgrenze

    31.25 pg/mL

    Analytische Methode

    Quantitative

    Spezifität

    This assay has high sensitivity and excellent specificity for detection of Cathepsin D (CTSD). No significant cross-reactivity or interference between Cathepsin D (CTSD) and analogues was observed.

    Sensitivität

    0.98 pg/mL
  • Kommentare

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Testdauer

    2 - 3 h

    Plattentyp

    Pre-coated

    Protokoll

    The microplate provided in this kit has been pre-coated with an antibody specific to Cathepsin D (CTSD). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Cathepsin D (CTSD). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Cathepsin D (CTSD) level in the sample or standard.,

    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cathepsin D (CTSD) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cathepsin D (CTSD) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Handhabung

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Lagerung

    4 °C,-20 °C

    Informationen zur Lagerung

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Haltbarkeit

    4-8 months
  • Target Alle Cathepsin D (CTSD) CLIA Kits anzeigen

    Cathepsin D (CTSD)

    Andere Bezeichnung

    Cathepsin D

    Hintergrund

    Gene Name: Cathepsin D

    Gene Aliases: CPSD, CLN10, Lysosomal Aspartyl Protease, Ceroid-Lipofuscinosis,Neuronal 10

    Gen-ID

    13033

    UniProt

    P18242

    Pathways

    Peptide Hormone Metabolism
Sie sind hier:
Chat with us!