Glucagon ELISA Kit

Das Huhn Glucagon ELISA Kit (ABIN5520692) ist ein Colorimetric ELISA Kit zur Detektion von Huhn Glucagon.
Produktnummer ABIN5520692
652,31 €
Zzgl. Versandkosten 20,00 € und MwSt
96 tests
Lieferung nach: Deutschland
Lieferung in 11 bis 15 Werktagen

Kurzübersicht für Glucagon ELISA Kit (ABIN5520692)

Target

Alle Glucagon (GCG) ELISA Kits anzeigen
Glucagon (GCG)

Reaktivität

  • 29
  • 18
  • 16
  • 12
  • 8
  • 5
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
Huhn

Nachweismethode

Colorimetric

Methodentyp

Competition ELISA

Detektionsbereich

1.563 pg/mL - 100 pg/mL

Applikation

ELISA

Proben

Cell Culture Supernatant, Cell Samples, Plasma, Serum, Tissue Lysate
  • Untere Nachweisgrenze

    1.563 pg/mL

    Verwendungszweck

    Chicken GC (Glucagon) ELISA Kit

    Analytische Methode

    Quantitative

    Spezifität

    Specifically binds with GC , no obvious cross reaction with other analogues.

    Sensitivität

    0.938 pg/mL

    Bestandteile

    • ELISA Microplate(Dismountable)
    • Lyophilized Standard
    • Biotin-labeled Antibody
    • HRP-Streptavidin Conjugate(SABC
    • 100X)
    • TMB Substrate
    • Sample Dilution Buffer
    • Stop Solution
    • Plate Sealer
    • Product Description

    Benötigtes Material

    • Microplate reader (wavelength: 450nm)
    • 37 °C incubator (CO2 incubator for cell culture is not recommenced.)
    • Automated plate washer or multi-channel pipette/5 mL pipettor
    • Precision single (0.5-10μL
    • 5-50μL
    • 20-200μL
    • 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
    • Sterile tubes and Eppendorf tubes with disposable tips
    • Absorbent paper and loading slot
    • Deionized or distilled water
  • Applikationshinweise

    Optimal working dilution should be determined by the investigator.

    Kommentare

    Competitive ELISA, Coated with Antigen

    Probenmenge

    50 μL

    Testdauer

    2 h

    Plattentyp

    Pre-coated

    Protokoll

    Step 1: Wash the plate twice before adding the standard and sample. Step 2: Add 50 µL standard or sample into each well. Immediately add 50 µL biotin-labeled antibody working solution into each well(The tip can't be reused after touching the liquid.), gently shake the plate for 1 min, seal closely and statically incubate for 45 minutes at 37 °C. Washing: Wash the plate three times and immerse for 1 min each time. Step 3: Add 100 µL HRP-Streptavidin Conjugate (SABC) working solution into each well, seal the plate and statically incubate for 30 minutes at 37 °C. Washing: Wash the plate five times and immerse for 1 min each time. Step 4: Add 90 µL TMB substrate solution, seal the plate and statically incubate for 10-20 minutes at 37 °C. (Accurate TMB visualization control is required.) Step 5: Add 50 µL stop solution. Read at 450nm immediately and calculate.

    Aufbereitung der Reagenzien

    • Bring all reagents and samples to room temperature for 20 minutes before use.
    • Wash Buffer: If crystals have formed in the concentrate, you can warm it with 40 °C water bath Concentrated Wash Buffer into 750 mL Wash Buffer with deionized or distilled water. Put unused solution back at 2-8 °C.
    • Standards:
      1. Add 1 mL Sample Dilution Buffer into one Standard tube (labeled as zero tube), keep the tube at room temperature for 10 minutes and mix them thoroughly. Note: If the standard tube concentration higher than the range of the kit,please dilute it and labeled as zero tube.
      2. Label 7 EP tubes with 1/2, 1/4, 1/8, 1/16, 1/32, 1/64 and blank respectively. Add 0.3 mLof the Sample Dilution Buffer into each tube. Add 0.3 mLof the above Standard solution (from zero tube) into 1st tube and mix them thoroughly. Transfer 0.3 mL from 1st tube to 2nd tube and mix them thoroughly. Transfer 0.3 mL from 2nd tube to 3rd tube and mix them thoroughly, and so on. Sample Dilution Buffer was used for the blank control. Note: It is best to use Standard Solutions within 2 hours.
    • Preparation of Biotin-labeled Antibody Working Solution:
      Prepare it within 1 hour before experiment.
      1. Calculate required total volume of the working solution: 0.05ml/well x quantity of wells. (Allow 0.1-0.2 mLmore than the total volume.)
      2. Dilute the Biotin-detection antibody with Antibody Dilution Buffer at 1:100 and mix them thoroughly. (i.e. Add 1 µL Biotin-labeled antibody into 99 µL Antibody Dilution Buffer.)
    • Preparation of HRP-Streptavidin Conjugate (SABC) Working Solution:
      Prepare it within 30 minutes before experiment.
      1. Calculate required total volume of the working solution: 0.1ml/well x quantity of wells. (Allow 0.1-0.2 mLmore than the total volume.)
      2. Dilute the SABC with SABC Dilution Buffer at 1:100 and mix them thoroughly. (i.e. Add 1 µL of SABC into 99 µL of SABC Dilution Buffer.)

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Handhabung

    Avoid direct light exposure to antibody solutions

    Lagerung

    4 °C

    Informationen zur Lagerung

    Store sealed Kit at 2-8° C. Do Not Cryopreserve. Store ELISA Microplate for 1 month at 2-8°C, Store for 12 month at -20°C. Put the leftover strips into a sealed foil bag with the desiccant

    Haltbarkeit

    12 months
  • Target Alle Glucagon (GCG) ELISA Kits anzeigen

    Glucagon (GCG)

    Andere Bezeichnung

    Glucagon

    Hintergrund

    Glicentin, GC

    UniProt

    P68259

    Pathways

    Positive Regulation of Peptide Hormone Secretion, Peptide Hormone Metabolism, cAMP Metabolic Process, Regulation of Carbohydrate Metabolic Process, Feeding Behaviour, Negative Regulation of intrinsic apoptotic Signaling