Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

EPAS1 ELISA Kit

Dieses Maus EPAS1 ELISA-Kit ist ein Colorimetric ELISA-Kit, das dafür entwickelt wurde, Maus EPAS1 zu quantifizieren.
Produktnummer ABIN5519204

Kurzübersicht für EPAS1 ELISA Kit (ABIN5519204)

Target

Alle EPAS1 ELISA Kits anzeigen
EPAS1 (Endothelial PAS Domain Protein 1 (EPAS1))

Reaktivität

  • 1
  • 1
  • 1
Maus

Nachweismethode

Colorimetric

Methodentyp

Sandwich ELISA

Detektionsbereich

0.31 ng/mL - 20 ng/mL

Applikation

ELISA

Proben

Plasma, Serum
  • Untere Nachweisgrenze

    0.31 ng/mL

    Verwendungszweck

    The kit is a sandwich enzyme immunoassay technique for the in vitro quantitative measurement in various sample types.

    Analytische Methode

    Quantitative

    Sensitivität

    0.19 ng/mL

    Bestandteile

    • Pre-coated, ready to use 96-well strip plate, flat buttom
    • Plate sealer for 96 wells
    • Reference Standard
    • Reference Standard & Sample Diluent
    • Biotinylated Detection Antibody (100 x concentrate)
    • HRP Conjugate (100 x concentrate)
    • Biotinylated Detection Antibody Diluent
    • HRP Conjugate Diluent
    • Substrate Reagent
    • Stop Solution
    • Wash Buffer (25 x concentrate)
    • Instruction manual
  • Probenmenge

    100 µL

    Testdauer

    1 - 4.5 h

    Plattentyp

    Pre-coated

    Protokoll

    1. Add 100 µL standard or sample to each well. Incubate for 90 min at 37 °C.
    2. Remove the liquid. Add 100 µL Biotinylated Detection Antibody. Incubate for 1 hour at 37 °C.
    3. Aspirate and wash 3 times.
    4. Add 100 µL HRP Conjugate. Incubate for 30 min at 37 °C.
    5. Aspirate and wash 5 times.
    6. Add 90 µL Substrate Reagent. Incubate for 15 min at 37 °C.
    7. Add 50 µL Stop Solution. Read at 450 nm immediately.
    8. Calculation of results.

    Aufbereitung der Reagenzien

    1. Bring all reagents to room temperature (18~25 °C) before use. Follow the Microplate reader manual for set-up and preheat it for 15 min before OD measurement.
    2. Wash Buffer: Dilute 30 mL of Concentrated Wash Buffer with 720 mL of deionized or distilled water to prepare 750 mL of Wash Buffer.Note: if crystals have formed in the concentrate, warm it in a 40 °C water bath and mix it gently until the crystals have completely dissolved
    3. Standard working solution: Centrifuge the standard at 10,000xg for 1 min. Add 1.0 mL of Reference Standard &Sample Diluent, let it stand for 10 min and invert it gently several times. After it dissolves fully, mix it thoroughly with a pipette. This reconstitution produces a working solution of 20 ng/mL. Then make serial dilutions as needed. The recommended dilution gradient is as follows: 20, 10, 5, 2.5, 1.25, 0.63, 0.31, 0 ng/mL. Dilution method: Take 7 EP tubes, add 500 μLof Reference Standard & Sample Diluent to each tube. Pipette 500 μLof the 20 ng/mL working solution to the first tube and mix up to produce a 10 ng/mL working solution. Pipette 500 μLof the solution from the former tube into the latter one according to these steps. The illustration below is for reference. Note: the last tube is regarded as a blank. Don't pipette solution into it from the former tube.
    4. Biotinylated Detection Antibody working solution: Calculate the required amount before the experiment (100 μL/well). In preparation, slightly more than calculated should be prepared. Centrifuge the stock tube before use, dilute the 100x Concentrated Biotinylated Detection Antibody to 1xworking solution with Biotinylated Detection Antibody Diluent.
    5. Concentrated HRP Conjugate working solution: Calculate the required amount before the experiment (100 μL/well). In preparation, slightly more than calculated should be prepared. Dilute the 100x Concentrated HRP Conjugate to 1x working solution with Concentrated HRP Conjugate Diluent.

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Lagerung

    4 °C/-20 °C

    Informationen zur Lagerung

    The unopened kit can be stored at 4℃ for 1 month. If the kit is not used within 1 month, store the items separately according to the conditions since the kit is received.
  • Target Alle EPAS1 ELISA Kits anzeigen

    EPAS1 (Endothelial PAS Domain Protein 1 (EPAS1))

    Andere Bezeichnung

    HIF-2alpha(Hypoxia Inducible Factor 2 Alpha)

    Pathways

    Signaling Events mediated by VEGFR1 and VEGFR2, Warburg Effekt
Sie sind hier: