Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

Complement C4 ELISA Kit

C4 Reaktivität: Ratte Colorimetric 12.5-800 ng/mL Plasma, Serum, Tissue Homogenate
Produktnummer ABIN367521
  • Target Alle Complement C4 (C4) ELISA Kits anzeigen
    Complement C4 (C4) (Complement 4 (C4))
    Reaktivität
    • 4
    • 3
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Ratte
    Nachweismethode
    Colorimetric
    Detektionsbereich
    12.5-800 ng/mL
    Untere Nachweisgrenze
    12.5 ng/mL
    Applikation
    ELISA
    Proben
    Serum, Plasma, Tissue Homogenate
    Analytische Methode
    Quantitative
    Kreuzreaktivität (Details)
    Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between the target antigen and all analogues for other species. Therefore, cross reaction may still exist.
    Sensitivität
    3.12 ng/mL
    Bestandteile
    • Assay plate (12 × 8 coated Microwells)
    • Standard (freeze dried)
    • Biotin-antibody (100 × concentrate)
    • HRP-avidin (100 × concentrate)
    • Biotin-antibody Diluent
    • HRP-avidin Diluent
    • Sample Diluent
    • Wash Buffer (25 × concentrate)
    • TMB Substrate
    • Stop Solution
    • Adhesive Strip (for 96 wells)
    • Instruction manual
    Featured
    Zu unserem meistverkauften C4 ELISA Kit
    Top Product
    Discover our top product C4 ELISA Kit
  • Applikationshinweise
    • The supplier is only responsible for the kit itself, but not for the samples consumed during the assay. The user should calculate the possible amount of the samples used in the whole test. Please reserve sufficient samples in advance.
    • Samples to be used within 5 days may be stored at 2-8°C, otherwise samples must be stored at -20°C (≤ 1 month) or -80°C (≤ 2 months) to avoid loss of bioactivity and contamination.
    • Grossly hemolyzed samples are not suitable for use in this assay.
    • If the samples are not indicated in the manual, a preliminary experiment to determine the validity of the kit is necessary.
    • Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their particular experiments.
    • Tissue or cell extraction samples prepared by chemical lysis buffer may cause unexpected ELISA results due to the impacts of certain chemicals.
    • Owing to the possibility of mismatching between antigens from another resource and antibodies used in this supplier's kits (e.g., antibody targets conformational epitope rather than linear epitope), some native or recombinant proteins from other manufacturers may not be recognized by this supplier's products.
    • Influenced by factors including cell viability, cell number and cell sampling time, samples from cell culture supernatant may not be recognized by the kit.
    • Fresh samples without long time storage are recommended for the test. Otherwise, protein degradation and denaturalization may occur in those samples and finally lead to wrong results.
    Kommentare

    Detection wavelength: 450 nm

    Information on standard material:
    Depending on the antigen to be detected, standards can be either native or recombinant protein. The recombinant proteins are being expressed in CHO cells in most cases. Please inquire for more information. The formulation of auxiliary material in the standard is considered proprietary information, however it does not contain any poisonous substance. Proclin 300 (1:3000) is used as preservative.

    Information on reagents:
    In most cases the stop solution provided is 1 N H2SO4. The formulation of wash solution is proprietary information. None of the components contain (sodium) azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials. For the sandwich method kits, the sample diluent, antibody diluent, enzyme diluent and standard all contain BSA.

    Information on antibodies:
    The antibodies provided in different kits vary in regards to clonality and host. Some antibodies are affinity purified, some are Protein A

    Testdauer
    1 - 4.5 h
    Plattentyp
    Pre-coated
    Testpräzision
    Intra-assay precision (precision within an assay): Three samples of known concentration were tested twenty times on one plate to assess precision.
    Inter-assay precision (precision between assays): Three samples of known concentration were tested in twenty assays to assess precision.
    • Intra-assay: CV% less than 8%
    • Inter-assay: CV% less than 10%
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Vorsichtsmaßnahmen
    The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face and clothing protection when using this material.
    Handhabung
    • The kit should not be used beyond the expiration date on the kit label.
    • Do not mix or substitute reagents with those from other lots or sources.
    • If samples generate values higher than the highest standard, dilute the samples with Sample Diluent and repeat the assay.
    • Any variation in Sample Diluent, operator, pipetting technique, washing technique, incubation time/temperature and kit age can cause variation in binding.
    • This assay is designed to eliminate interference by soluble receptors, binding proteins and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
    Lagerung
    4 °C/-20 °C
    Informationen zur Lagerung
    For unopened kit: All the reagents should be kept according to the labels on vials.
    Haltbarkeit
    6 months
  • Liu, Chen, Yang, Jiang, Chen, Tu, Mao, Hu, Gan, Li, Li: "iTRAQ-based proteomic analysis to identify the molecular mechanism of Zhibai Dihuang Granule in the Yin-deficiency-heat syndrome rats." in: Chinese medicine, Vol. 13, pp. 2, (2018) (PubMed).

  • Target Alle Complement C4 (C4) ELISA Kits anzeigen
    Complement C4 (C4) (Complement 4 (C4))
    Abstract
    C4 Produkte
    Synonyme
    C4B1 ELISA Kit, C4B12 ELISA Kit, C4B2 ELISA Kit, C4B3 ELISA Kit, C4B5 ELISA Kit, C4BD ELISA Kit, C4B_2 ELISA Kit, C4F ELISA Kit, CH ELISA Kit, CO4 ELISA Kit, CPAMD3 ELISA Kit, C4 ELISA Kit, C4A2 ELISA Kit, C4A3 ELISA Kit, C4A4 ELISA Kit, C4A6 ELISA Kit, C4AD ELISA Kit, C4S ELISA Kit, CPAMD2 ELISA Kit, RG ELISA Kit, C4-1 ELISA Kit, C4b ELISA Kit, C4-2 ELISA Kit, Slp ELISA Kit, Ss ELISA Kit, complement C4B (Chido blood group) ELISA Kit, complement C4A (Rodgers blood group) ELISA Kit, complement component 4A (Rodgers blood group) ELISA Kit, complement 4 ELISA Kit, complement component 4A ELISA Kit, complement component 4B (Chido blood group) ELISA Kit, C4B ELISA Kit, C4A ELISA Kit, C4a ELISA Kit, C4 ELISA Kit, C4b ELISA Kit
    Pathways
    Komplementsystem
Sie sind hier:
Kundenservice