MICA ELISA Kit
Kurzübersicht für MICA ELISA Kit (ABIN1846998)
Target
Alle MICA ELISA Kits anzeigenReaktivität
Nachweismethode
Methodentyp
Detektionsbereich
Applikation
Proben
-
-
Untere Nachweisgrenze
- 0.156 ng/mL
-
Verwendungszweck
- Human MHC Class I Polypeptide Related Sequence A (MICA) ELISA Kit
-
Analytische Methode
- Quantitative
-
Sensitivität
- < 0.06 ng/mL
-
Bestandteile
-
The kit components listed are for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
- Pre-coated 96-Well Microplate
- Standard
- Standard Diluent Buffer
- Wash Buffer
- Detection Reagent A
- Detection Reagent B
- Diluent A
- Diluent B
- TMB Substrate
- Stop Solution
- Plate Sealer
-
Benötigtes Material
-
- 37 °C incubator
- Multi and single channel pipettes and sterile pipette tips
- Squirt bottle or automated microplate washer
- 1.5 mL tubes
- Distilled water
- Absorbent filter papers
- 100 mL and 1 liter graduated cylinders
- Microplate reader (wavelength: 450 nm)
- ELISA Shaker
-
-
-
-
Applikationshinweise
- Optimal dilutions/concentrations should be determined by the end user.
-
Kommentare
-
The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5 % within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.
-
Plattentyp
- Pre-coated
-
Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, medium and high levels of major histocompatibility complex class I chain-related gene A were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, medium and high levels of major histocompatibility complex class I chain-related gene A were tested on 3 different plates, 8 replicates in each plate.
CV (%) = (Standard Deviation / mean) x 100
Intra-Assay: CV<10%
Inter-Assay: CV<10%
-
Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
-
-
Lagerung
- 4 °C
-
Informationen zur Lagerung
- Shipped at 4 °C. Upon receipt, store the kit according to the storage instruction in the kit's manual.
-
Haltbarkeit
- 6 months
-
-
- MICA (MHC Class I Polypeptide-Related Sequence A (MICA))
-
Andere Bezeichnung
- MHC Class I Polypeptide Related Sequence A
-
Pathways
- Activation of Innate immune Response, Transition Metal Ion Homeostasis, Human Leukocyte Antigen (HLA) in Adaptive Immune Response
Target Alle MICA ELISA Kits anzeigen
-