IgG4 Protein
Kurzübersicht für IgG4 Protein (ABIN7668932)
Target
Protein-Typ
Biologische Aktivität
Spezies
Quelle
Reinheit
-
-
Verwendungszweck
- Recombinant Human IgG4-Fc Protein (108 Ser/Pro)
-
Sequenz
- Glu 99-Lys 327, 108Ser/Pro
-
Aufreinigung
- > 95 % as determined by reducing SDS-PAGE.
-
Sterilität
- 0.2 μm filtered
-
Endotoxin-Niveau
- < 1.0 EU per μg of the protein as determined by the LAL method.
-
-
Möchten Sie weitere Optionen für dieses Protein ?
!Entdecken Sie unsere vordefinierten maßgeschneiderten Proteine und Proteinservices!Ihr Projekt erfordert weitere Anpassungen? Kontaktieren Sie uns und entdecken Sie unsere maßgeschneiderten Proteinlösungen
-
-
-
Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
-
-
Format
- Lyophilized
-
Buffer
-
Lyophilized from sterile PBS, pH 7.4
Normally 5 % - 8 % trehalose, mannitol and 0.01 % Tween 80 are added as protectants before lyophilization. -
Lagerung
- 4 °C,-20 °C,-80 °C
-
Informationen zur Lagerung
- Generally, lyophilized proteins are stable for up to 12 months when stored at -20 to -80°C. Reconstituted protein solution can be stored at 4-8°C for 2-7 days. Aliquots of reconstituted samples are stable at < -20°C for 3 months.
-
Haltbarkeit
- 12 months
-
-
- IgG4
-
Substanzklasse
- Antibody
-
Hintergrund
- SCN3B (sodium channel, voltage-gated, type III, beta ,human IgG1-Fc chimera) belongs to the sodium channel auxiliary subunit SCN3B family. It contains 1 Ig-like C2-type (immunoglobulin-like) domain. Voltage-gated sodium channels are transmembrane glycoprotein complexes composed of a large alpha subunit and one or more regulatory beta subunits. They are responsible for the generation and propagation of action potentials in neurons and muscle. SCN3B gene encodes one member of the sodium channel beta subunit gene family, and influences the inactivation kinetics of the sodium channel. Two alternatively spliced variants, encoding the same protein, have been identified. Defects in SCN3B are the cause of Brugada syndrome type 7. A tachyarrhythmia characterized by right bundle branch block and ST segment elevation on an electrocardiogram. It can cause the ventricles to beat so fast that the blood is prevented from circulating efficiently in the body. When this situation occurs (called ventricular fibrillation), the individual will faint and may die in a few minutes if the heart is not reset.,IGHG4,Ig gamma-4 chain C region,IgG4 Fc
-
Molekulargewicht
-
calculated_mw: 25.5 kDa
observed_mw: 35 kDa
-
UniProt
- P01861
Target
-