Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

ORM1 ELISA Kit

Dieses Affe ORM1 ELISA-Kit ist ein Colorimetric ELISA-Kit, das dafür entwickelt wurde, Affe ORM1 in Plasma und Serum zu quantifizieren.
Produktnummer ABIN956166

Kurzübersicht für ORM1 ELISA Kit (ABIN956166)

Target

Alle ORM1 ELISA Kits anzeigen
ORM1 (Orosomucoid 1 (ORM1))

Reaktivität

  • 5
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Affe

Nachweismethode

Colorimetric

Methodentyp

Sandwich ELISA

Applikation

ELISA

Proben

Plasma, Serum
  • Analytische Methode

    Quantitative

    Produktmerkmale

    The Monkey -1-AGP ELISA is based on a solid phase enzyme-linked immunosorbent assay (ELISA). The assay uses affinity purified anti-monkey -1-AGP antibodies for solid phase (microtiter wells) immobilization and horseradish peroxidase (HRP) conjugated anti-monkey -1-AGP antibodies for detection. The test sample is diluted and incubated in the microtiter wells for 45 minutes. The microtiter wells are subsequently washed and HRP conjugate is added and incubated for 45 minutes. This results in -1-AGP molecules being sandwiched between the immobilization and detection antibodies. The wells are then washed to remove unbound HRP-labeled antibodies and TMB Reagent is added and incubated for 20 minutes at room temperature. This results in the development of a blue color. Color development is stopped by the addition of Stop Solution, changing the color to yellow, and optical density is measured spectrophotometrically at 450 nm. The concentration of -1-AGP is proportional to the optical density of the test sample.

    Bestandteile

    Anti-monkey -1-AGP antibody coated microtiter plate with 96 wells (provided as 12 detachable strips of 8)
    Enzyme Conjugate Reagent, 11 mL
    Monkey -1-AGP Calibrator (lyophilized) Note: International import/export restrictions apply to monkey derived products. In order to avoid such restrictions the monkey -1-AGP calibrator supplied with this kit is of non-monkey origin. The calibration curve obtained with this material is identical to that obtained with monkey -1-AGP.
    Diluent (10X), 25 mL
    Wash Solution (20X), 50 mL
    TMB Reagent (One-Step), 11 mL
    Stop Solution (1N HCl), 11 mL.

    Benötigtes Material

    Precision pipettes and tips
    Distilled or de-ionized water
    Polypropylene or glass tubes
    Vortex mixer
    Absorbent paper or paper towels
    Micro-Plate incubator/shaker mixing speed of ~150 rpm
    A microtiter plate reader capable of measuring absorbance at 450 nm, with a bandwidth of 10 nm or less and an OD range of 0-4 OD
    Graph paper (PC graphing software is optional)
  • Plattentyp

    Pre-coated

    Aufbereitung der Proben

    General Note: Our studies find that -1-AGP may be present in monkey serum at concentrations of 0.2 to 2 mg/mL. In order to obtain values within the range of the calibration curve we suggest that samples initially be diluted 20,000 fold using the following procedure for each sample to be tested:
    1. Dispense 198 µL and 497.5 µL of 1X diluent into two tubes.
    2. Pipette and mix 2 µL of the serum/plasma sample into the tube containing 198 µL of 1X diluent. This provides a 100 fold diluted sample.
    3. Mix 2.5 µL of the 100 fold diluted sample with the 497.5 µL of diluent in the second tube. This provides a 20,000 fold dilution of the sample.
    4. Repeat this procedure for each sample to be tested.

    Testdurchführung

    1. Secure the desired number of coated wells in the holder.
      2. Dispense 100 µL of calibrators and samples into the wells (we recommend that samples be tested in duplicate).
      3. Incubate on an orbital micro-plate shaker at 100-150 rpm at room temperature (18-25°C) for 45 minutes.
      4. Remove the incubation mixture using a plate washer or by flicking plate contents into an appropriate Bio-waste container.
      5. Wash and empty the microtiter wells 5 times with 1X wash solution. This may be performed using either a plate washer (400 µL/well) or with a squirt bottle. The entire wash procedure should be performed as quickly as possible.
      6. Strike the wells sharply onto adsorbent paper or paper towels to remove all residual droplets.
      7. Add 100 µL of enzyme conjugate reagent into each well.
      8. Incubate on an orbital micro-plate shaker at 100-150 rpm at room temperature (18-25°C) for 45 minutes.
      9. Wash as detailed in 4 and 5 above.
      10. Strike the wells sharply onto absorbent paper or paper towels to remove residual droplets.
      11. Dispense 100 µL of TMB Reagent into each well.
      12. Gently mix on an orbital micro-plate shaker at 100-150 rpm at room temperature (18-25°C) for 20 minutes.
      13. Stop the reaction by adding 100 µL of Stop Solution to each well.
      14. Gently mix. It is important to make sure that all the blue color changes to yellow.
      15. Read the optical density at 450 nm with a microtiter plate reader within 15 minutes.

    Ergebnisberechnung

    1. Calculate the average absorbance values (A450) for each set of reference calibrators, and samples.
      2. Construct a calibration curve by plotting the mean absorbance obtained from each reference calibrator against its concentration in ng/mL on linear graph paper, with absorbance values on the vertical or Y-axis and concentrations on the horizontal or X-axis.
      3. Using the mean absorbance value for each sample, determine the corresponding concentration of -1-AGP in ng/mL from the calibration curve.
      4. Multiply the derived concentrations by the dilution factor to determine the actual concentration of -1-AGP in the serum/plasma sample.
      5. If available, PC graphing software may be used for the above steps.
      6. If the OD450 values of samples fall outside the calibration curve when tested at the suggested dilution of 20,000, samples should be diluted appropriately and re-tested.

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Lagerung

    4 °C

    Informationen zur Lagerung

    The unused kit should be stored at 4°C and the microtiter plate should be kept in a sealed bag with desiccant to minimize exposure to damp air. Test kits will remain stable until the expiration date provided that the components are stored as described above.

    Haltbarkeit

    The expiry date is stated on the label.
  • Target Alle ORM1 ELISA Kits anzeigen

    ORM1 (Orosomucoid 1 (ORM1))

    Andere Bezeichnung

    Alpha-1 Acid Glycoprotein