Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

C6 ELISA Kit

Dieses Colorimetric ELISA kit dient der quantitativen Messung von Human C6.
Produktnummer ABIN8068476
1.004,26 €
Zzgl. Versandkosten 20,00 € und MwSt
96 tests
Lieferung nach: Deutschland
Lieferung in 25 bis 47 Werktagen

Kurzübersicht für C6 ELISA Kit (ABIN8068476)

Target

Alle C6 ELISA Kits anzeigen
C6 (Complement Component 6 (C6))

Bindungsspezifität

Oxidized Form, total

Reaktivität

  • 16
  • 3
  • 1
Human

Nachweismethode

Colorimetric

Methodentyp

Sandwich ELISA

Applikation

ELISA

Proben

Cell Lysate, Tissue Lysate
  • Verwendungszweck

    Measures oxidated C6 and total C6 in human cell and tissue lysates, enabling precise assessment of C6 oxidation by ELISA. This assay can be developed for other species (mouse, rat, etc.) upon request. Contact techsupport@raybiotech.com.

    Analytische Methode

    Quantitative

    Bestandteile

      Size / Qty
        • Microplate Coated With Anti-Pan-C6 Antibody
        • Positive Control
        • HRP-Conjugated Streptavidin
        • 200 μL
        • Wash Buffer
        • Assay Diluent
        • Lysis Buffer
        • TMB One-Step Substrate Reagent
        • Stop Solution
        • Oxidation Buffer A
        • Oxidation Buffer B
        • Oxidation Labeling Reagent
        • Oxidation Stabilizing Reagent

    Benötigtes Material

    • 20 % (v/v) trichloroacetic acid (TCA) solution, ice-cold
    • 1:1 (v/v) ethanol:ethyl acetate
    • Benchtop centrifuge and microcentrifuge (4 °C)
    • Microplate reader capable of measuring absorbance at 450 nm
    • Protease and Phosphatase inhibitors
    • Precision pipettes to deliver 2 μL to 1 mL volumes
    • Adjustable 1-25 mL pipettes for reagent preparation
    • 100 mL and 1 liter graduated cylinders
    • Log-log graph paper or computer and software for ELISA data analysis
    • Absorbent paper
    • Tubes to prepare positive control or sample dilutions
    • Distilled or deionized water
    • Shaker
  • Applikationshinweise

    Optimal working dilution should be determined by the investigator.

    Plattentyp

    Pre-coated

    Protokoll

    1. Prepare all reagents, samples and Positive Control as instructed.
    2. Label samples with Oxidation Labeling Reagent
    3. Add Oxidation Stabilizing Reagent to samples.
    4. Precipitate proteins with ice-cold 20 % TCA.
    5. Wash protein pellet twice with 1:1 (v/v) ethanol:ethyl acetate.
    6. Resuspend protein pellets in Oxidation Buffer B.
    7. Add 100 μL sample and Positive Control to each well. Incubate 2.5 hours at room temperature or overnight at 4 °C with gentle shaking.
    8. Add 100 μL prepared HRP-Conjugated Streptavidin solution. Incubate for 1 hour at room temperature with gentle shaking.
    9. Add 100 μL TMB One-Step Substrate Reagent to each well. Incubate 30 minutes at room temperature.
    10. Add 50 μL Stop Solution to each well. Read at 450 nm immediately.

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Lagerung

    -20 °C

    Informationen zur Lagerung

    The entire kit may be stored at -20°C for up to 6 months from the date of shipment. Avoid repeated freeze-thaw cycles.
  • Target Alle C6 ELISA Kits anzeigen

    C6 (Complement Component 6 (C6))

    Andere Bezeichnung

    C6

    Hintergrund

    Gene Symbols: C6

    Background: The Oxidated C6 ELISA Kit uses the "biotin probes" method to biotin label carbonyl groups of oxidized proteins. In this method, the biotin probes first react with carbonyl groups of oxidized proteins to form unstable Schiff bases, which are then further reduced to more stable amines. The biotinylated proteins can then be detected by ELISA. An anti-pan C6 antibody has been coated onto a 96-well plate. Biotinylated samples are pipetted into the wells, and C6 present in a sample is bound to the wells by the immobilized antibody. The wells are washed, and HRP-conjugated streptavidin is used to detect oxidated C6. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of oxidated C6 bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm.

    Protein Name (Synonyms): Complement component C6

    Gen-ID

    729

    UniProt

    P13671
Sie sind hier:
Chat with us!