Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

CX3CL1 ELISA Kit

Das Maus CX3CL1 ELISA Kit (ABIN8056726) ist ein Colorimetric ELISA Kit zur Detektion von Maus CX3CL1.
Produktnummer ABIN8056726
924,00 €
Zzgl. Versandkosten 20,00 € und MwSt
96 tests
Lieferung nach: Deutschland
Lieferung in 11 bis 15 Werktagen

Kurzübersicht für CX3CL1 ELISA Kit (ABIN8056726)

Target

Alle CX3CL1 ELISA Kits anzeigen
CX3CL1 (Chemokine (C-X3-C Motif) Ligand 1 (CX3CL1))

Reaktivität

  • 22
  • 18
  • 16
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Maus

Nachweismethode

Colorimetric

Methodentyp

Sandwich ELISA

Detektionsbereich

78 pg/mL - 5000 pg/mL

Applikation

ELISA

Proben

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate

Güteklasse

Small Sample
  • Untere Nachweisgrenze

    78 pg/mL

    Verwendungszweck

    Mini Samples ELISA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1)

    Analytische Methode

    Quantitative

    Spezifität

    This assay has high sensitivity and excellent specificity for detection of Mini Samples Chemokine C-X3-C-Motif Ligand 1 (CX3CL1).
    No significant cross-reactivity or interference between Mini Samples Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) and analogues was observed.

    Bestandteile

    • Pre-coated, 96-well strip plate
    • Plate sealer
    • Standard
    • Standard Diluent
    • Detection Reagent A
    • Assay Diluent A
    • Detection Reagent B
    • Assay Diluent B
    • TMB Substrate
    • Stop Solution
    • Wash Buffer (30X)
    • Instruction manual

    Benötigtes Material

    • Microplate reader with 450 ± 10nm filter.
    • Precision single or multi-channel pipettes and disposable tips.
    • Eppendorf Tubes for diluting samples.
    • Deionized or distilled water.
    • Absorbent paper for blotting the microtiter plate.
    • Container for Wash Solution
  • Probenmenge

    25 μL

    Testdauer

    3 h

    Plattentyp

    Pre-coated

    Protokoll

    1. Prepare all reagents, samples and standards;
    2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
    3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
    4. Aspirate and wash 3 times;
    5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
    6. Aspirate and wash 5 times;
    7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
    8. Add 20µL Stop Solution. Read at 450nm immediately.

    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Handhabung

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Lagerung

    4 °C,-20 °C

    Informationen zur Lagerung

    • For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
    • For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
      Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.
    • For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.

    Haltbarkeit

    6 months
  • Target Alle CX3CL1 ELISA Kits anzeigen

    CX3CL1 (Chemokine (C-X3-C Motif) Ligand 1 (CX3CL1))

    Andere Bezeichnung

    Chemokine C-X3-C-Motif Ligand 1

    Hintergrund

    NTN, ABCD3, C3Xkine, CXC3, CXC3C, NTT, SCYD1, ABCD3, FKN, Neurotactin, Fractalkine, Small Inducible Cytokine Subfamily D(Cys-X3-Cys)Member 1

    UniProt

    P78423

    Pathways

    Synaptic Membrane
Sie sind hier: