AMH ELISA Kit
Kurzübersicht für AMH ELISA Kit (ABIN8056121)
Target
Alle AMH ELISA Kits anzeigenReaktivität
Nachweismethode
Methodentyp
Detektionsbereich
Applikation
Proben
-
-
Untere Nachweisgrenze
- 3.12 ng/mL
-
Verwendungszweck
- ELISA Kit for Anti-Anti-Mullerian Hormone Antibody (Anti-AMH)
-
Analytische Methode
- Quantitative
-
Spezifität
-
This assay has high sensitivity and excellent specificity for detection of Anti-Anti-Mullerian Hormone Antibody (Anti-AMH).
No significant cross-reactivity or interference between Anti-Anti-Mullerian Hormone Antibody (Anti-AMH) and analogues was observed. -
Sensitivität
- < 1.19 ng/mL
-
Bestandteile
-
- Pre-coated, 96-well strip plate
- Plate sealer
- Standard
- Standard Diluent
- Detection Reagent A
- Assay Diluent A
- TMB Substrate
- Stop Solution
- Wash Buffer (30X)
- Instruction manual
-
Benötigtes Material
-
- Microplate reader with 450 ± 10nm filter.
- Precision single or multi-channel pipettes and disposable tips.
- Eppendorf Tubes for diluting samples.
- Deionized or distilled water.
- Absorbent paper for blotting the microtiter plate.
- Container for Wash Solution
-
-
-
-
Probenmenge
- 100 μL
-
Testdauer
- 2.5 h
-
Plattentyp
- Pre-coated
-
Protokoll
-
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 5 times;
5. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
6. Add 50µL Stop Solution. Read at 450nm immediately.
-
Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Anti-Anti-Mullerian Hormone Antibody (Anti-AMH) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Anti-Anti-Mullerian Hormone Antibody (Anti-AMH) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
-
Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
-
-
Handhabung
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. -
Lagerung
- 4 °C,-20 °C
-
Informationen zur Lagerung
-
- For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
- For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit. - For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.
-
Haltbarkeit
- 6 months
-
-
- AMH (Anti-Mullerian Hormone (AMH))
-
Andere Bezeichnung
- Anti-Mullerian Hormone
-
Hintergrund
- MIF, MIH, MIS, Müllerian Inhibiting Factor, Müllerian Inhibiting Hormone, Müllerian Inhibiting Substance
-
UniProt
- P27106
-
Pathways
- Negative Regulation of Hormone Secretion
Target Alle AMH ELISA Kits anzeigen
-