Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

MFGE8 CLIA Kit

Dieses Chemiluminescent ELISA kit dient der quantitativen Messung von Human MFGE8.
Produktnummer ABIN8056080
975,33 €
Zzgl. Versandkosten 20,00 € und MwSt
96 tests
Lieferung nach: Deutschland
Lieferung in 11 bis 15 Werktagen

Kurzübersicht für MFGE8 CLIA Kit (ABIN8056080)

Target

Alle MFGE8 CLIA Kits anzeigen
MFGE8 (Milk Fat Globule-EGF Factor 8 Protein (MFGE8))

Reaktivität

  • 15
  • 12
  • 6
  • 2
  • 2
Human

Nachweismethode

Chemiluminescent

Methodentyp

Sandwich ELISA

Detektionsbereich

31.2 pg/mL - 2000 pg/mL

Applikation

ELISA

Proben

Cell Lysate, Plasma, Serum
  • Untere Nachweisgrenze

    31.2 pg/mL

    Verwendungszweck

    CLIA Kit for Milk Fat Globule EGF Factor 8 (MFGE8)

    Analytische Methode

    Quantitative

    Spezifität

    This assay has high sensitivity and excellent specificity for detection of Milk Fat Globule EGF Factor 8 (MFGE8).
    No significant cross-reactivity or interference between Milk Fat Globule EGF Factor 8 (MFGE8) and analogues was observed.

    Sensitivität

    < 12.2 pg/mL

    Bestandteile

    • Pre-coated, 96-well strip plate
    • Plate sealer
    • Standard
    • Standard Diluent
    • Detection Reagent A
    • Assay Diluent A
    • Detection Reagent B
    • Assay Diluent B
    • Substrate A
    • Substrate B
    • Wash Buffer (30X)
    • Instruction manual

    Benötigtes Material

    • Luminometer capable of reading 96-well microplates with the following parameters: lag time 30.0secs; read time 1.0 sec/well
    • Single or multi-channel pipettes with high precision and disposable tips.
    • Microcentrifuge Tubes.
    • Deionized or distilled water.
    • Absorbent paper for blotting the microplate.
    • Container for Wash Solution.
    • 0.01mol/L (or 1×) Phosphate Buffered Saline(PBS), pH7.0-7.2
  • Probenmenge

    100 μL

    Testdauer

    3 h

    Plattentyp

    Pre-coated

    Protokoll

    1. Prepare all reagents, samples and standards;
    2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C;
    3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
    4. Aspirate and wash 3 times;
    5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
    6. Aspirate and wash 5 times;
    7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
    8. Read RLU value immediately.

    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Milk Fat Globule EGF Factor 8 (MFGE8) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Milk Fat Globule EGF Factor 8 (MFGE8) were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Handhabung

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Lagerung

    4 °C,-20 °C

    Informationen zur Lagerung

    • For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
    • For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
      Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.
    • For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.

    Haltbarkeit

    6 months
  • Target Alle MFGE8 CLIA Kits anzeigen

    MFGE8 (Milk Fat Globule-EGF Factor 8 Protein (MFGE8))

    Andere Bezeichnung

    Milk Fat Globule EGF Factor 8

    Hintergrund

    HMFG, MFGM, SED1, BA46, EDIL1, OAcGD3S, SPAG10, hP47, Medin, Lactadherin, Sperm Associated Antigen 10, Sperm Surface Protein hP47, Milk fat globule-EGF factor 8

    UniProt

    Q08431

    Pathways

    SARS-CoV-2 Protein Interaktom