Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

AMH CLIA Kit

Das Ratte AMH ELISA Kit (ABIN8056021) ist ein Chemiluminescent ELISA Kit zur Detektion von Ratte AMH.
Produktnummer ABIN8056021
1.003,44 €
Zzgl. Versandkosten 20,00 € und MwSt
96 tests
Lieferung nach: Deutschland
Lieferung in 11 bis 15 Werktagen

Kurzübersicht für AMH CLIA Kit (ABIN8056021)

Target

Alle AMH CLIA Kits anzeigen
AMH (Anti-Mullerian Hormone (AMH))

Reaktivität

  • 18
  • 15
  • 15
  • 9
  • 8
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
Ratte

Nachweismethode

Chemiluminescent

Methodentyp

Competition ELISA

Detektionsbereich

312 pg/mL - 5000 pg/mL

Applikation

ELISA

Proben

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
  • Untere Nachweisgrenze

    312 pg/mL

    Verwendungszweck

    CLIA Kit for Anti-Mullerian Hormone (AMH)

    Analytische Methode

    Quantitative

    Spezifität

    This assay has high sensitivity and excellent specificity for detection of Anti-Mullerian Hormone (AMH).
    No significant cross-reactivity or interference between Anti-Mullerian Hormone (AMH) and analogues was observed.

    Sensitivität

    < 107 pg/mL

    Bestandteile

    • Pre-coated, 96-well strip plate
    • Plate sealer
    • Standard
    • Standard Diluent
    • Detection Reagent A
    • Assay Diluent A
    • Detection Reagent B
    • Assay Diluent B
    • Substrate A
    • Substrate B
    • Wash Buffer (30X)
    • Instruction manual

    Benötigtes Material

    • Luminometer capable of reading 96-well microplates with the following parameters: lag time 30.0secs; read time 1.0 sec/well
    • Single or multi-channel pipettes with high precision and disposable tips.
    • Microcentrifuge Tubes.
    • Deionized or distilled water.
    • Absorbent paper for blotting the microplate.
    • Container for Wash Solution.
    • 0.01mol/L (or 1×) Phosphate Buffered Saline(PBS), pH7.0-7.2
  • Probenmenge

    50 μL

    Testdauer

    2 h

    Plattentyp

    Pre-coated

    Protokoll

    1. Prepare all reagents, samples and standards;
    2. Add 50µL standard or sample to each well.
        And then add 50µL prepared Detection Reagent A immediately.
        Shake and mix. Incubate 1 hour at 37°C;
    3. Aspirate and wash 3 times;
    4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
    5. Aspirate and wash 5 times;
    6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
    7. Read RLU value immediately.

    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Anti-Mullerian Hormone (AMH) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Anti-Mullerian Hormone (AMH) were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Handhabung

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Lagerung

    4 °C,-20 °C

    Informationen zur Lagerung

    • For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
    • For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
      Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.
    • For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.

    Haltbarkeit

    6 months
  • Target Alle AMH CLIA Kits anzeigen

    AMH (Anti-Mullerian Hormone (AMH))

    Andere Bezeichnung

    Anti-Mullerian Hormone

    Hintergrund

    MIF, MIH, MIS, Müllerian Inhibiting Factor, Müllerian Inhibiting Hormone, Müllerian Inhibiting Substance

    UniProt

    P49000

    Pathways

    Negative Regulation of Hormone Secretion
Sie sind hier:
Chat with us!