NOS2 ELISA Kit

NOS2 Reaktivität: Ratte Colorimetric Sandwich ELISA 0.78 IU/mL - 50 IU/mL Plasma, Serum, Tissue Homogenate
Produktnummer ABIN6974078
  • Target Alle NOS2 ELISA Kits anzeigen
    NOS2 (Nitric Oxide Synthase 2, Inducible (NOS2))
    Reaktivität
    • 5
    • 4
    • 4
    • 3
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    Ratte
    Nachweismethode
    Colorimetric
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    0.78 IU/mL - 50 IU/mL
    Untere Nachweisgrenze
    0.78 IU/mL
    Applikation
    ELISA
    Verwendungszweck
    For the quantitative determination of rat inducible nitric oxide synthase (iNOS) concentrations in serum, plasma, tissue homogenates.
    Proben
    Plasma, Serum, Tissue Homogenate
    Analytische Methode
    Quantitative
    Spezifität
    This assay has high sensitivity and excellent specificity for detection of rat iNOS. No significant cross-reactivity or interference between rat iNOS and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between rat iNOS and all the analogues, therefore, cross reaction may still exist.
    Sensitivität
    0.195 IU/mL
    Bestandteile
    • Assay plate
    • Standard
    • HRP-avidin (100 x concentrate)
    • Biotin-antibody (100 x concentrate)
    • Sample Diluent
    • HRP-avidin Diluent
    • Biotin-antibody Diluent
    • Wash Buffer (25 x concentrate)
    • TMB Substrate
    • Stop Solution
    • Adhesive Strip
    Top Product
    Discover our top product NOS2 ELISA Kit
  • Applikationshinweise
    Optimal working dilution should be determined by the investigator.
    Probenmenge
    100 μL
    Testdauer
    1 - 4.5 h
    Plattentyp
    Pre-coated
    Protokoll
    1. Prepare reagents, samples and standards as instructed.
    2. Add 100 µL standard or sample to each well. Incubate 2 hours at 37 °C.
    3. Remove the liquid of each well, don't wash.
    4. Add 100 µL Biotin-antibody (1x) to each well. Incubate 1 hour at 37 °C.
    5. Aspirate and wash 3 times.
    6. Add 100 µL HRP-avidin (1x) to each well. Incubate 1 hour at 37 °C
    7. Aspirate and wash 5 times.
    8. Add 90 μL of TMB Substrate to each well. Incubate for 15-30 minutes at 37 °C. Protect from light.
    9. Add 50 µL Stop Solution to each well. Read at 450 nm within 5 minutes.
    Aufbereitung der Reagenzien
    1. Biotin-antibody (1x) - Centrifuge the vial before opening. Biotin-antibody requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of Biotin-antibody + 990 μL of Biotin-antibody Diluent.
    2. HRP-avidin (1x) - Centrifuge the vial before opening. HRP-avidin requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of HRP-avidin + 990 μL of HRP-avidin Diluent.
    3. Wash Buffer (1x) - If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 mL of Wash Buffer Concentrate (25 x) into deionized or distilled water to prepare 500 mL of Wash Buffer (1 x).
    4. Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 mL of Sample Diluent. Do not substitute other diluents. This reconstitution produces a stock solution of 50 IU/mL. Mix the standard to ensure complete reconstitution and allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making dilutions. Pipette 250 μL of Sample Diluent into each tube (S0-S6). Use the stock solution to produce a 2-fold dilution series (below). Mix each tube thoroughly before the next transfer. The undiluted Standard serves as the high standard (50 IU/mL). Sample Diluent serves as the zero standard (0 IU/mL).
    Note:
    • Kindly use graduated containers to prepare the reagent. Please don't prepare the reagent directly in the Diluent vials provided in the kit.
    • Bring all reagents to room temperature (18-25 °C) before use for 30 min.
    • Prepare fresh standard for each assay. Use within 4 hours and discard after use.
    • Making serial dilution in the wells directly is not permitted.
    • Please carefully reconstitute Standards according to the instruction, and avoid foaming and mix gently until the crystals have completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10 μL for once pipetting.
    • Distilled water is recommended to be used to make the preparation for reagents. Contaminated water or container for reagent preparation will influence the detection result.
    Aufbereitung der Proben
    • It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturationmay occur in these samples, leading to false results. Samples should therefore be stored for a short periodat 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thawcycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged toremove precipitates.
    • If the sample type is not specified in the instructions, a preliminary test is necessary to determinecompatibility with the kit.
    • If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibilityof causing a deviation due to the introduced chemical substance.The recommended dilution factor is for reference only.
    • Please estimate the concentration of the samples before performing the test. If the values are not in therange of the standard curve, the optimal sample dilution for the particular experiment has to be determined.Samples should then be diluted with PBS (pH =7.0-7.2).
    Testpräzision
    Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess.
    Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess.
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Lagerung
    4 °C,-20 °C
    Informationen zur Lagerung
    Unopened kit Store at 2 - 8°C. Do not use the kit beyond the expiration date May be stored for up to 1 month at 2 - 8°C. Coated assay Try to keep it in a sealed aluminum foil bag, plate and avoid the damp. Standard May be stored for up to 1 month at 2 - 8° C. If Biotin-antibody don't make recent use, better keep it store at HRP-avidin -20°C. Biotin-antibody Diluent Opened kit HRP-avidin Diluent Sample May be stored for up to 1 month at 2 - 8°C. Diluent Wash Buffer TMB Substrate Stop Solution *Provided this is within the expiration date of the kit.
    Haltbarkeit
    6 months
  • Kim, Ko, Jo, Arai, Choi, Kumar, Han, Sohn: "Anti-inflammatory effect of Tauroursodeoxycholic acid in RAW 264.7 macrophages, Bone marrow-derived macrophages, BV2 microglial cells, and spinal cord injury." in: Scientific reports, Vol. 8, Issue 1, pp. 3176, (2019) (PubMed).

    Zhao, Tang, Zhang, Liu, Li: "Magnesium isoglycyrrhizinate protects against renal‑ischemia‑reperfusion injury in a rat model via anti‑inflammation, anti‑oxidation and anti‑apoptosis." in: Molecular medicine reports, Vol. 16, Issue 3, pp. 3627-3633, (2018) (PubMed).

    Aras, Akçilar, Koçak, Koçak, Savran, Metineren, Karakuş, Yücel: "Effect of ukrain on ischemia/reperfusion-induced kidney injury in rats." in: The Journal of surgical research, Vol. 202, Issue 2, pp. 267-75, (2017) (PubMed).

    Tang, Yang, Zhang, Ren, Sang, Lu, Zhong, Mao: "Magnesium isoglycyrrhizinate inhibits inflammatory response through STAT3 pathway to protect remnant liver function." in: World journal of gastroenterology, Vol. 21, Issue 43, pp. 12370-80, (2016) (PubMed).

  • Target Alle NOS2 ELISA Kits anzeigen
    NOS2 (Nitric Oxide Synthase 2, Inducible (NOS2))
    Andere Bezeichnung
    nitric oxide synthase 2, inducible (NOS2 Produkte)
    Synonyme
    HEP-NOS ELISA Kit, INOS ELISA Kit, NOS ELISA Kit, NOS2A ELISA Kit, NOS-II ELISA Kit, Nos-2 ELISA Kit, Nos2a ELISA Kit, i-NOS ELISA Kit, iNOS ELISA Kit, iNos ELISA Kit, NOS2a ELISA Kit, NOS2 ELISA Kit, BmNOS2 ELISA Kit, Nsl ELISA Kit, nos2 ELISA Kit, nitric oxide synthase 2 ELISA Kit, nitric oxide synthase 2, inducible ELISA Kit, inducible nitric oxide synthase ELISA Kit, inducible nitric-oxide synthase ELISA Kit, nanos C2HC-type zinc finger 2 ELISA Kit, NOS2 ELISA Kit, Nos2 ELISA Kit, nos2 ELISA Kit, LOC396821 ELISA Kit, NANOS2 ELISA Kit
    Hintergrund

    Abbreviation: NOS2

    Alias: HEP-NOS, INOS, NOS, NOS2A, NOS, type II|nitric oxide synthase 2A|nitric oxide synthase 2A (inducible, hepatocytes)|nitric oxide synthase, macrophage

    UniProt
    Q06518
    Pathways
    Retinoic Acid Receptor Signaling Pathway, Cellular Response to Molecule of Bacterial Origin, Inositol Metabolic Process, Regulation of Leukocyte Mediated Immunity, Positive Regulation of Immune Effector Process
Sie sind hier:
Kundenservice