SAMD4B ELISA Kit

Dieses Colorimetric ELISA-Kit wurde entwickelt für die quantitative Messung von Human SAMD4B.
Produktnummer ABIN6234726

Kurzübersicht für SAMD4B ELISA Kit (ABIN6234726)

Target

Alle SAMD4B Produkte
SAMD4B (Sterile alpha Motif Domain Containing 4B (SAMD4B))

Reaktivität

Human

Nachweismethode

Colorimetric

Methodentyp

Sandwich ELISA

Detektionsbereich

0.156 ng/mL - 10 ng/mL

Applikation

ELISA

Proben

Cell Lysate, Tissue Homogenate
  • Untere Nachweisgrenze

    0.156 ng/mL

    Verwendungszweck

    Human Sterile Alpha Motif Domain Containing 4B (SAMD4B) ELISA Kit

    Analytische Methode

    Quantitative

    Sensitivität

    < 0.094 ng/mL

    Bestandteile

    The kit components listed are for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
    • Pre-coated 96-Well Microplate
    • Standard
    • Standard Diluent Buffer
    • Wash Buffer
    • Detection Reagent A
    • Detection Reagent B
    • Diluent A
    • Diluent B
    • TMB Substrate
    • Stop Solution
    • Plate Sealer

    Benötigtes Material

    • 37 °C incubator
    • Multi and single channel pipettes and sterile pipette tips
    • Squirt bottle or automated microplate washer
    • 1.5 mL tubes
    • Distilled water
    • Absorbent filter papers
    • 100 mL and 1 liter graduated cylinders
    • Microplate reader (wavelength: 450 nm)
    • ELISA Shaker
  • Applikationshinweise

    Optimal dilutions/concentrations should be determined by the end user.

    Kommentare

    The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5 % within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.

    Plattentyp

    Pre-coated

    Aufbereitung der Reagenzien

    This procedure is provided for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.

    • 1) Standard: Prepare the standard with the recommended volume of Standard Diluent Buffer, to make the standard solution. Then use the Standard Diluent buffer to carry out serial dilutions of the standard solution, as instructed in the Protocol.
    • 2) Wash Buffer: Dilute the concentrated Wash Buffer with distilled water, as instructed in the Protocol.
    • 3) Detection Reagent Preparation: Calculate the total volume of working solution required. Dilute Detection Reagent A and Detection Reagent B with Diluent A and Diluent B, respectively, at 1:100.

    Probennahme

    • Serum: Samples should be collected into a serum separator tube. Coagulate the serum by leaving the tube undisturbed in a vertical position overnight at 4 °C or at room temperature for up to 60 minutes. Centrifuge at approximately 1000 x g for 20 min. Analyze the serum immediately or aliquot and store at -20 °C or -80 °C.
    • Plasma: Collect plasma using heparin or EDTA as an anticoagulant. Centrifuge for 15 minutes at 1000 x g within 30 minutes of collection. Assay immediately or aliquot and store at -20 °C or -80 °C. Avoid hemolysis and high cholesterol samples.
    • Tissue homogenates: The preparation of tissue homogenates will vary depending upon tissue type - this is just an example. Rinse tissues with ice-cold PBS to remove the excess of blood. Weigh before homogenization. Finely mince tissues and homogenize with a tissue homogenizer on ice in PBS and sonicate the cell suspension. Centrifuge the homogenates at 5000 x g for 5 min and collect the supernatant. Assay immediately or aliquot and store at -20 °C.

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Lagerung

    4 °C

    Informationen zur Lagerung

    Shipped at 4 °C. Upon receipt, store the kit according to the storage instruction in the kit's manual.

    Haltbarkeit

    6 months
  • Target Alle SAMD4B Produkte

    SAMD4B (Sterile alpha Motif Domain Containing 4B (SAMD4B))

    Andere Bezeichnung

    Sterile Alpha Motif Domain Containing 4B

    Hintergrund

    Ensembl: ENSG00000179134

    UniProt Entry Name: SMAG2_HUMAN

    Gen-ID

    55095

    HGNC

    25492

    UniProt

    Q5PRF9