GIDRP88 ELISA Kit

Human GIDRP88 ELISA-Kit Colorimetric-Assay zur Quantifizierung von Human GIDRP88.
Produktnummer ABIN6230099

Kurzübersicht für GIDRP88 ELISA Kit (ABIN6230099)

Target

Alle GIDRP88 (C10orf28) Produkte
GIDRP88 (C10orf28) (Chromosome 10 Open Reading Frame 28 (C10orf28))

Reaktivität

Human

Nachweismethode

Colorimetric

Methodentyp

Sandwich ELISA

Detektionsbereich

0.313 ng/mL - 20 ng/mL

Applikation

ELISA

Proben

Cell Lysate, Tissue Homogenate
  • Untere Nachweisgrenze

    0.313 ng/mL

    Verwendungszweck

    Human Chromosome 10 Open Reading Frame 28 (R3HCC1L) ELISA Kit

    Analytische Methode

    Quantitative

    Sensitivität

    < 0.19 ng/mL

    Bestandteile

    The kit components listed are for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
    • Pre-coated 96-Well Microplate
    • Standard
    • Standard Diluent Buffer
    • Wash Buffer
    • Detection Reagent A
    • Detection Reagent B
    • Diluent A
    • Diluent B
    • TMB Substrate
    • Stop Solution
    • Plate Sealer

    Benötigtes Material

    • 37 °C incubator
    • Multi and single channel pipettes and sterile pipette tips
    • Squirt bottle or automated microplate washer
    • 1.5 mL tubes
    • Distilled water
    • Absorbent filter papers
    • 100 mL and 1 liter graduated cylinders
    • Microplate reader (wavelength: 450 nm)
    • ELISA Shaker
  • Applikationshinweise

    Optimal dilutions/concentrations should be determined by the end user.

    Kommentare

    The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5 % within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.

    Probenmenge

    100 µL

    Plattentyp

    Pre-coated

    Aufbereitung der Reagenzien

    This procedure is provided for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.

    • 1) Standard: Prepare the standard with the recommended volume of Standard Diluent Buffer, to make the standard solution. Then use the Standard Diluent buffer to carry out serial dilutions of the standard solution, as instructed in the Protocol.
    • 2) Wash Buffer: Dilute the concentrated Wash Buffer with distilled water, as instructed in the Protocol.
    • 3) Detection Reagent Preparation: Calculate the total volume of working solution required. Dilute Detection Reagent A and Detection Reagent B with Diluent A and Diluent B, respectively, at 1:100.

    Testdurchführung

    This procedure is provided for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.

    • Equilibrate the kit components and samples to room temperature (18 - 25 °C) before use. It is recommended to plot a standard curve for each test.
    • 1. Set standard, test sample and control (zero) wells on the pre-coated plate respectively, and then, record their positions. It is recommended to measure each standard and sample at least in duplicate.
    • 2. Add 100 μL of each standard, control and sample into the appropriate wells. Seal the plate with a cover and incubate for 1 h at 37 °C.
    • 3. Remove the cover and discard the liquid.
    • 4. Add 100 μL of the detection Reagent A working solution to each well. Seal the plate with a cover and incubate for 1 h at 37 °C.
    • 5. Remove the cover and discard the solution. Wash the plate 3 times with 1X Wash Buffer.
    • 6. Add 100 μL of Detection Reagent B working solution into each well, seal and incubate at 37 °C for 30 min.
    • 7. Discard the solution and wash the plate 5 times with wash buffer as explained in previous step.
    • 8. Aliquot 90 μL of TMB Substrate into each well. Seal the plate with a cover and incubate at 37 °C for 10-20 min. Avoid exposure to light. The incubation time is for reference use only, the optimal time should be determined by end user. Do not exceed 30 min.
    • 9. Add 50 μL of Stop Solution to each well. Read at 450 nm immediately.

    Ergebnisberechnung

    For calculation, average the O.D.450 duplicate readings for each reference standard and each sample and substract the average control (zero) O.D.450 reading. The standard curve can be plotted as the relative O.D.450 of each reference standard solution [Y] vs. the respective concentration of each standard solution (X). The R3HCC1L concentration of the samples can be interpolated from the standard curve.

    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, medium and high levels of Growth Inhibition And Differentiation Related Protein 88 (GIDRP88) were tested 20 times on one plate, respectively.

    Inter-assay Precision (Precision between assays): 3 samples with low, medium and high levels of Growth Inhibition And Differentiation Related Protein 88 (GIDRP88) were tested on 3 different plates, 8 replicates in each plate.

    CV (%) = (Standard Deviation / mean) x 100

    Intra-Assay: CV<10%

    Inter-Assay: CV<12%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Lagerung

    4 °C

    Informationen zur Lagerung

    Shipped at 4 °C. Upon receipt, store the kit according to the storage instruction in the kit's manual.

    Haltbarkeit

    6 months
  • Target Alle GIDRP88 (C10orf28) Produkte

    GIDRP88 (C10orf28) (Chromosome 10 Open Reading Frame 28 (C10orf28))

    Andere Bezeichnung

    Chromosome 10 Open Reading Frame 28

    Hintergrund

    Ensembl: ENSG00000166024

    UniProt Entry Name: R3HCL_HUMAN

    Gen-ID

    27291

    HGNC

    23512

    UniProt

    Q7Z5L2