OxLDL ELISA Kit
Kurzübersicht für OxLDL ELISA Kit (ABIN5657572)
Target
Alle OxLDL ELISA Kits anzeigenReaktivität
Nachweismethode
Methodentyp
Detektionsbereich
Applikation
Proben
-
-
Untere Nachweisgrenze
- 2.47 ng/mL
-
Analytische Methode
- Quantitative
-
Spezifität
- This assay has high sensitivity and excellent specificity for detection of Oxidized Low Density Lipoprotein (OxLDL). No significant cross-reactivity or interference between Oxidized Low Density Lipoprotein (OxLDL) and analogues was observed.
-
Sensitivität
- 0.89 ng/mL
-
-
-
-
Kommentare
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
-
Testdauer
- 2 h
-
Plattentyp
- Pre-coated
-
Protokoll
- This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Oxidized Low Density Lipoprotein (OxLDL) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Oxidized Low Density Lipoprotein (OxLDL) and unlabeled Oxidized Low Density Lipoprotein (OxLDL) (Standards or samples) with the pre-coated antibody specific to Oxidized Low Density Lipoprotein (OxLDL). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Oxidized Low Density Lipoprotein (OxLDL) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Oxidized Low Density Lipoprotein (OxLDL) in the sample.
-
Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Oxidized Low Density Lipoprotein (OxLDL) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Oxidized Low Density Lipoprotein (OxLDL) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% -
Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
-
-
Handhabung
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Lagerung
- 4 °C,-20 °C
-
Informationen zur Lagerung
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Haltbarkeit
- 4-8 months
-
-
- OxLDL (Oxidized Low Density Lipoprotein (OxLDL))
-
Andere Bezeichnung
- Oxidized Low Density Lipoprotein
-
Hintergrund
-
Gene Name: Oxidized Low Density Lipoprotein
Gene Aliases: OL
Target Alle OxLDL ELISA Kits anzeigen
-