ODC1 ELISA Kit

Dieses Colorimetric ELISA kit dient der quantitativen Messung von Human ODC1.
Produktnummer ABIN5657523
1.031,31 €
Zzgl. Versandkosten 20,00 € und MwSt
96 tests
Lieferung nach: Deutschland
Lieferung in 12 bis 18 Werktagen

Kurzübersicht für ODC1 ELISA Kit (ABIN5657523)

Target

Alle ODC1 ELISA Kits anzeigen
ODC1 (Ornithine Decarboxylase 1 (ODC1))

Reaktivität

  • 8
  • 7
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Human

Nachweismethode

Colorimetric

Methodentyp

Sandwich ELISA

Detektionsbereich

0.312 ng/mL - 20 ng/mL

Applikation

ELISA

Proben

Plasma, Serum, Tissue Homogenate
  • Untere Nachweisgrenze

    0.312 ng/mL

    Analytische Methode

    Quantitative

    Spezifität

    This assay has high sensitivity and excellent specificity for detection of Ornithine Decarboxylase (ODC). No significant cross-reactivity or interference between Ornithine Decarboxylase (ODC) and analogues was observed.

    Sensitivität

    0.127 ng/mL
  • Kommentare

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Testdauer

    3 h

    Plattentyp

    Pre-coated

    Protokoll

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Ornithine Decarboxylase (ODC). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Ornithine Decarboxylase (ODC). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Ornithine Decarboxylase (ODC), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Ornithine Decarboxylase (ODC) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ornithine Decarboxylase (ODC) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ornithine Decarboxylase (ODC) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Handhabung

    The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Lagerung

    4 °C,-20 °C

    Informationen zur Lagerung

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Haltbarkeit

    4-8 months
  • Target Alle ODC1 ELISA Kits anzeigen

    ODC1 (Ornithine Decarboxylase 1 (ODC1))

    Andere Bezeichnung

    Ornithine Decarboxylase

    Hintergrund

    Gene Name: Ornithine Decarboxylase

    Gene Aliases: ODC1

    Gen-ID

    4953

    UniProt

    P11926
Sie sind hier:
Chat with us!