Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

NOX1 CLIA Kit

Ratte NOX1 ELISA Kit, Chemiluminescent Assay für die Quantifizierung von Ratte NOX1.
Produktnummer ABIN5657378
1.355,31 €
Zzgl. Versandkosten 20,00 € und MwSt
96 tests
Lieferung nach: Deutschland
Lieferung in 12 bis 18 Werktagen

Kurzübersicht für NOX1 CLIA Kit (ABIN5657378)

Target

Alle NOX1 CLIA Kits anzeigen
NOX1 (NADPH Oxidase 1 (NOX1))

Reaktivität

  • 13
  • 13
  • 7
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Ratte

Nachweismethode

Chemiluminescent

Methodentyp

Sandwich ELISA

Detektionsbereich

27.4 pg/mL - 20000 pg/mL

Applikation

ELISA

Proben

Tissue Homogenate
  • Untere Nachweisgrenze

    27.4 pg/mL

    Verwendungszweck

    Rat Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) CLIA Kit for detecting NOX1 in tissue homogenates

    Analytische Methode

    Quantitative

    Spezifität

    This assay has high sensitivity and excellent specificity for detection of Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1). No significant cross-reactivity or interference between Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) and analogues was observed.

    Sensitivität

    11.8 pg/mL

    Bestandteile

    • Pre-coated, ready to use 96-well strip plate
    • Standar
    • Detection Reagent A
    • Detection Reagent B
    • Substrate A
    • Substrate B
    • Assay Diluent A
    • Assay Diluent B
    • Wash Buffer (30x concentrate)
    • Standard Diluent
    • Plate Sealer
    • Instruction Manual

    Benötigtes Material

    • Microplate Reader with 450 nm filter
    • Single or multi-channel pipettes with high precision and disposable tips
    • Microcentrifuge tubes
    • Deionized or distilled watter
    • Absorbent paper for blotting the microplate
    • Container for wash solution
    • 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
  • Applikationshinweise

    Optimal working dilution should be determined by the investigator.

    Kommentare

    This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.

    Probenmenge

    100 μL

    Testdauer

    3 h

    Plattentyp

    Pre-coated

    Protokoll

    The microplate provided in this kit has been pre-coated with an antibody specific to Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) level in the sample or standard.,

    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Handhabung

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Lagerung

    4 °C,-20 °C

    Informationen zur Lagerung

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Haltbarkeit

    12 months
  • Target Alle NOX1 CLIA Kits anzeigen

    NOX1 (NADPH Oxidase 1 (NOX1))

    Andere Bezeichnung

    Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1

    Hintergrund

    Gene Aliases: MOX1, GP91-2, NOH1, NADPH Oxidase 1, Mitogenic Oxidase (Pyridine Nucleotide-Dependent Superoxide-Generating, NADH/NADPH mitogenic oxidase subunit P65-MOX

    Gen-ID

    114243

    UniProt

    Q9WV87

    Pathways

    Regulation of Systemic Arterial Blood Pressure by Hormones, Proton Transport
Sie sind hier:
Chat with us!