Myeloperoxidase ELISA Kit
Kurzübersicht für Myeloperoxidase ELISA Kit (ABIN5657056)
Target
Alle Myeloperoxidase (MPO) ELISA Kits anzeigenReaktivität
Nachweismethode
Methodentyp
Detektionsbereich
Applikation
Proben
-
-
Untere Nachweisgrenze
- 3.12 ng/mL
-
Analytische Methode
- Quantitative
-
Spezifität
- This assay has high sensitivity and excellent specificity for detection of Myeloperoxidase (MPO). No significant cross-reactivity or interference between Myeloperoxidase (MPO) and analogues was observed.
-
Sensitivität
- 1.12 ng/mL
-
-
-
-
Kommentare
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
-
Testdauer
- 2 - 3 h
-
Plattentyp
- Pre-coated
-
Protokoll
- This assay employs the competitive inhibition enzyme immunoassay technique. An antibody specific to Myeloperoxidase (MPO) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between Horseradish Peroxidase (HRP) labeled Myeloperoxidase (MPO) and unlabeled Myeloperoxidase (MPO) (Standards or samples) with the pre-coated antibody specific to Myeloperoxidase (MPO). After incubation the unbound conjugate is washed off. The amount of bound HRP conjugate is reverse proportional to the concentration of Myeloperoxidase (MPO) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Myeloperoxidase (MPO) in the sample.
-
Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Myeloperoxidase (MPO) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Myeloperoxidase (MPO) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% -
Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
-
-
Handhabung
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Lagerung
- 4 °C,-20 °C
-
Informationen zur Lagerung
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Haltbarkeit
- 4-8 months
-
-
- Myeloperoxidase (MPO)
-
Andere Bezeichnung
- Myeloperoxidase
-
Hintergrund
-
Gene Name: Myeloperoxidase
-
Gen-ID
- 4353
-
UniProt
- P05164
-
Pathways
- Chromatin Binding
Target Alle Myeloperoxidase (MPO) ELISA Kits anzeigen
-