Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

MMP7 CLIA Kit

Das Pferd MMP7 ELISA Kit (ABIN5656774) ist ein Chemiluminescent ELISA Kit zur Detektion von Pferd MMP7.
Produktnummer ABIN5656774
1.512,35 €
Zzgl. Versandkosten 20,00 € und MwSt
96 tests
Lieferung nach: Deutschland
Lieferung in 12 bis 18 Werktagen

Kurzübersicht für MMP7 CLIA Kit (ABIN5656774)

Target

Alle MMP7 CLIA Kits anzeigen
MMP7 (Matrix Metallopeptidase 7 (Matrilysin, Uterine) (MMP7))

Reaktivität

  • 21
  • 12
  • 10
  • 5
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
Pferd

Nachweismethode

Chemiluminescent

Methodentyp

Sandwich ELISA

Detektionsbereich

312.5 pg/mL - 20000 pg/mL

Applikation

ELISA

Proben

Plasma, Serum
  • Untere Nachweisgrenze

    312.5 pg/mL

    Analytische Methode

    Quantitative

    Spezifität

    This assay has high sensitivity and excellent specificity for detection of Matrix Metalloproteinase 7 (MMP7). No significant cross-reactivity or interference between Matrix Metalloproteinase 7 (MMP7) and analogues was observed.

    Sensitivität

    10.87 pg/mL
  • Kommentare

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Testdauer

    2 - 3 h

    Plattentyp

    Pre-coated

    Protokoll

    The microplate provided in this kit has been pre-coated with an antibody specific to Matrix Metalloproteinase 7 (MMP7). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Matrix Metalloproteinase 7 (MMP7). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Matrix Metalloproteinase 7 (MMP7) level in the sample or standard.,

    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Matrix Metalloproteinase 7 (MMP7) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Matrix Metalloproteinase 7 (MMP7) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Handhabung

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Lagerung

    4 °C,-20 °C

    Informationen zur Lagerung

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Haltbarkeit

    4-8 months
  • Target Alle MMP7 CLIA Kits anzeigen

    MMP7 (Matrix Metallopeptidase 7 (Matrilysin, Uterine) (MMP7))

    Andere Bezeichnung

    Matrix Metalloproteinase 7

    Hintergrund

    Gene Name: Matrix Metalloproteinase 7

    Gene Aliases: MPSL1, MAT, PUMP-1, Matrilysin Uterine, Matrilysin, Matrin, Pump-1 Protease, Uterine Metalloproteinase

    Pathways

    Production of Molecular Mediator of Immune Response
Sie sind hier: