IL4I1 CLIA Kit

Human IL4I1 ELISA-Kit Chemiluminescent-Assay zur Quantifizierung von Human IL4I1.
Produktnummer ABIN5655992

Kurzübersicht für IL4I1 CLIA Kit (ABIN5655992)

Target

Alle IL4I1 CLIA Kits anzeigen
IL4I1 (Interleukin 4 Induced 1 (IL4I1))

Reaktivität

  • 3
  • 1
Human

Nachweismethode

Chemiluminescent

Methodentyp

Sandwich ELISA

Detektionsbereich

312.5 pg/mL - 20000 pg/mL

Applikation

ELISA

Proben

Tissue Homogenate
  • Untere Nachweisgrenze

    312.5 pg/mL

    Analytische Methode

    Quantitative

    Spezifität

    This assay has high sensitivity and excellent specificity for detection of Interleukin 4 Induced Protein 1 (IL4I1). No significant cross-reactivity or interference between Interleukin 4 Induced Protein 1 (IL4I1) and analogues was observed.

    Sensitivität

    11.45 pg/mL
  • Kommentare

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Testdauer

    2 - 3 h

    Plattentyp

    Pre-coated

    Protokoll

    The microplate provided in this kit has been pre-coated with an antibody specific to Interleukin 4 Induced Protein 1 (IL4I1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interleukin 4 Induced Protein 1 (IL4I1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interleukin 4 Induced Protein 1 (IL4I1) level in the sample or standard.,

    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 4 Induced Protein 1 (IL4I1) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 4 Induced Protein 1 (IL4I1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Handhabung

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Lagerung

    4 °C,-20 °C

    Informationen zur Lagerung

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Haltbarkeit

    4-8 months
  • Target Alle IL4I1 CLIA Kits anzeigen

    IL4I1 (Interleukin 4 Induced 1 (IL4I1))

    Andere Bezeichnung

    Interleukin 4 Induced Protein 1

    Hintergrund

    Gene Name: Interleukin 4 Induced Protein 1

    Gene Aliases: FIG1, LAAO, LAO, FIG1, L-amino-acid oxidase

    Gen-ID

    259307

    UniProt

    Q96RQ9