Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

Estrone CLIA Kit

Dieses Diverse Spezies Estrone ELISA-Kit ist ein Chemiluminescent ELISA-Kit, das dafür entwickelt wurde, Diverse Spezies Estrone zu quantifizieren.
Produktnummer ABIN5653996

Kurzübersicht für Estrone CLIA Kit (ABIN5653996)

Target

Alle Estrone CLIA Kits anzeigen
Estrone

Reaktivität

  • 3
  • 1
Diverse Spezies

Nachweismethode

Chemiluminescent

Methodentyp

Competition ELISA

Detektionsbereich

23.44 pg/mL - 6000 pg/mL

Applikation

ELISA

Proben

Plasma, Serum
  • Untere Nachweisgrenze

    23.44 pg/mL

    Analytische Methode

    Quantitative

    Spezifität

    This assay has high sensitivity and excellent specificity for detection of Estrone (E1). No significant cross-reactivity or interference between Estrone (E1) and analogues was observed.

    Sensitivität

    7.96 pg/mL
  • Kommentare

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Testdauer

    2 h

    Plattentyp

    Pre-coated

    Protokoll

    The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Estrone (E1). A competitive inhibition reaction is launched between biotin labeled Estrone (E1) and unlabeled Estrone (E1) (Standards or samples) with the pre-coated antibody specific to Estrone (E1). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Estrone (E1) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Estrone (E1) level in the sample or standard.

    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Estrone (E1) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Estrone (E1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Handhabung

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Lagerung

    4 °C,-20 °C

    Informationen zur Lagerung

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Haltbarkeit

    4-8 months
  • Target Alle Estrone CLIA Kits anzeigen

    Estrone

    Substanzklasse

    Amino Acid

    Hintergrund

    Gene Name: Estrone

    Gene Aliases: Oestrone

Sie sind hier: