Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

Complement C3 Convertase ELISA Kit

Human Complement C3 Convertase ELISA Kit, Colorimetric Assay für die Quantifizierung von Human Complement C3 Convertase.
Produktnummer ABIN5653199
967,85 €
Zzgl. Versandkosten 20,00 € und MwSt
96 tests
Lieferung nach: Deutschland
Lieferung in 12 bis 18 Werktagen

Kurzübersicht für Complement C3 Convertase ELISA Kit (ABIN5653199)

Target

Alle Complement C3 Convertase Produkte
Complement C3 Convertase

Reaktivität

  • 12
  • 3
  • 2
Human

Nachweismethode

Colorimetric

Methodentyp

Sandwich ELISA

Detektionsbereich

0.312 ng/mL - 20 ng/mL

Applikation

ELISA

Proben

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
  • Untere Nachweisgrenze

    0.312 ng/mL

    Verwendungszweck

    Human Complement C3 Convertase (C3 Convertase) High-sensitive ELISA Kit for detecting C3 Convertase in serum, plasma, tissue homogenates, cell lysates, cell culture supernates

    Analytische Methode

    Quantitative

    Spezifität

    This assay has high sensitivity and excellent specificity for detection of Complement C3 Convertase (C3c). No significant cross-reactivity or interference between Complement C3 Convertase (C3c) and analogues was observed.

    Sensitivität

    0.122 ng/mL

    Bestandteile

    • Pre-coated, ready to use 96-well strip plate
    • Standar
    • Detection Reagent A
    • Detection Reagent B
    • TMB Substrate
    • Stop Solution
    • Assay Diluent A
    • Assay Diluent B
    • Wash Buffer (30x concentrate)
    • Standard Diluent
    • Plate Sealer
    • Instruction Manual

    Benötigtes Material

    • Microplate Reader with 450 nm filter
    • Single or multi-channel pipettes with high precision and disposable tips
    • Microcentrifuge tubes
    • Deionized or distilled watter
    • Absorbent paper for blotting the microplate
    • Container for wash solution
    • 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
  • Applikationshinweise

    Optimal working dilution should be determined by the investigator.

    Kommentare

    This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.

    Probenmenge

    100 μL

    Testdauer

    3 h

    Plattentyp

    Pre-coated

    Protokoll

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Complement C3 Convertase (C3c). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Complement C3 Convertase (C3c). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Complement C3 Convertase (C3c), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Complement C3 Convertase (C3c) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement C3 Convertase (C3c) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement C3 Convertase (C3c) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Handhabung

    The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Lagerung

    4 °C,-20 °C

    Informationen zur Lagerung

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Haltbarkeit

    12 months
  • Target Alle Complement C3 Convertase Produkte

    Complement C3 Convertase

    Hintergrund

    Gene Aliases: C4b2a, C3bBb, complement C.hivin.4.hivin2

    Gen-ID

    718

    UniProt

    P01024