CGB ELISA Kit
Kurzübersicht für CGB ELISA Kit (ABIN5652939)
Target
Alle CGB ELISA Kits anzeigenReaktivität
Nachweismethode
Methodentyp
Detektionsbereich
Applikation
Proben
-
-
Untere Nachweisgrenze
- 12.35 ng/mL
-
Verwendungszweck
- Human Chorionic Gonadotropin Beta Polypeptide (CGb) ELISA Kit for detecting CGb in serum, plasma, tissue homogenates, cell lysates, cell culture supernates
-
Analytische Methode
- Quantitative
-
Spezifität
- This assay has high sensitivity and excellent specificity for detection of Chorionic Gonadotropin Beta Polypeptide (CGb). No significant cross-reactivity or interference between Chorionic Gonadotropin Beta Polypeptide (CGb) and analogues was observed.
-
Sensitivität
- 4.64 ng/mL
-
Bestandteile
-
- Pre-coated, ready to use 96-well strip plate
- Standar
- Detection Reagent A
- Detection Reagent B
- TMB Substrate
- Stop Solution
- Assay Diluent A
- Assay Diluent B
- Wash Buffer (30x concentrate)
- Standard Diluent
- Plate Sealer
- Instruction Manual
-
Benötigtes Material
-
- Microplate Reader with 450 nm filter
- Single or multi-channel pipettes with high precision and disposable tips
- Microcentrifuge tubes
- Deionized or distilled watter
- Absorbent paper for blotting the microplate
- Container for wash solution
- 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
-
-
-
-
Applikationshinweise
- Optimal working dilution should be determined by the investigator.
-
Kommentare
-
This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.
-
Probenmenge
- 50 μL
-
Testdauer
- 2 h
-
Plattentyp
- Pre-coated
-
Protokoll
- This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Chorionic Gonadotropin Beta Polypeptide (CGb) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Chorionic Gonadotropin Beta Polypeptide (CGb) and unlabeled Chorionic Gonadotropin Beta Polypeptide (CGb) (Standards or samples) with the pre-coated antibody specific to Chorionic Gonadotropin Beta Polypeptide (CGb). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Chorionic Gonadotropin Beta Polypeptide (CGb) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Chorionic Gonadotropin Beta Polypeptide (CGb) in the sample.
-
Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chorionic Gonadotropin Beta Polypeptide (CGb) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chorionic Gonadotropin Beta Polypeptide (CGb) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% -
Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
-
-
Handhabung
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Lagerung
- 4 °C,-20 °C
-
Informationen zur Lagerung
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Haltbarkeit
- 12 months
-
-
- CGB (Chorionic Gonadotropin, beta Polypeptide (CGB))
-
Andere Bezeichnung
- Chorionic Gonadotropin Beta Polypeptide
-
Hintergrund
- Gene Aliases: CG-B, CGB3, hCGB, HCG, CGb5, CGb7, CGb8, Choriogonadotropin subunit beta
-
Gen-ID
- 1082
-
UniProt
- P0DN86
Target Alle CGB ELISA Kits anzeigen
-