CHRNA1 CLIA Kit
Kurzübersicht für CHRNA1 CLIA Kit (ABIN5652918)
Target
Alle CHRNA1 CLIA Kits anzeigenReaktivität
Nachweismethode
Methodentyp
Detektionsbereich
Applikation
Proben
-
-
Untere Nachweisgrenze
- 68.6 pg/mL
-
Verwendungszweck
- Human Cholinergic Receptor, Nicotinic, Alpha 1 (CHRNa1) CLIA Kit for detecting CHRNa1 in tissue homogenates
-
Analytische Methode
- Quantitative
-
Spezifität
- This assay has high sensitivity and excellent specificity for detection of Cholinergic Receptor, Nicotinic, Alpha 1 (CHRNa1). No significant cross-reactivity or interference between Cholinergic Receptor, Nicotinic, Alpha 1 (CHRNa1) and analogues was observed.
-
Sensitivität
- 29.5 pg/mL
-
Bestandteile
-
- Pre-coated, ready to use 96-well strip plate
- Standar
- Detection Reagent A
- Detection Reagent B
- Substrate A
- Substrate B
- Assay Diluent A
- Assay Diluent B
- Wash Buffer (30x concentrate)
- Standard Diluent
- Plate Sealer
- Instruction Manual
-
Benötigtes Material
-
- Microplate Reader with 450 nm filter
- Single or multi-channel pipettes with high precision and disposable tips
- Microcentrifuge tubes
- Deionized or distilled watter
- Absorbent paper for blotting the microplate
- Container for wash solution
- 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
-
-
-
-
Applikationshinweise
- Optimal working dilution should be determined by the investigator.
-
Kommentare
-
This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.
-
Probenmenge
- 100 μL
-
Testdauer
- 3 h
-
Plattentyp
- Pre-coated
-
Protokoll
- The microplate provided in this kit has been pre-coated with an antibody specific to Cholinergic Receptor, Nicotinic, Alpha 1 (CHRNa1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Cholinergic Receptor, Nicotinic, Alpha 1 (CHRNa1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Cholinergic Receptor, Nicotinic, Alpha 1 (CHRNa1) level in the sample or standard.,
-
Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cholinergic Receptor, Nicotinic, Alpha 1 (CHRNa1) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cholinergic Receptor, Nicotinic, Alpha 1 (CHRNa1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% -
Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
-
-
Handhabung
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Lagerung
- 4 °C,-20 °C
-
Informationen zur Lagerung
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Haltbarkeit
- 12 months
-
-
- CHRNA1 (Acetylcholine Receptor Subunit alpha (CHRNA1))
-
Andere Bezeichnung
- Cholinergic Receptor, Nicotinic, Alpha 1
-
Hintergrund
- Gene Aliases: CHR-NA1, N-AChRA1, NAChRA1, ACHRA, ACHRD, CMS2A, FCCMS, SCCMS, Acetylcholine receptor subunit alpha, N-AChR-A1, Neuronal Acetylcholine Receptor Alpha 1,Muscle
-
Gen-ID
- 1134
-
UniProt
- P02708
-
Pathways
- Skeletal Muscle Fiber Development
Target Alle CHRNA1 CLIA Kits anzeigen
-