Arginine CLIA Kit
Kurzübersicht für Arginine CLIA Kit (ABIN5652005)
Target
Alle Arginine (ARG) CLIA Kits anzeigenReaktivität
Nachweismethode
Methodentyp
Detektionsbereich
Applikation
Proben
-
-
Untere Nachweisgrenze
- 390.6 ng/mL
-
Verwendungszweck
- Arginine (Arg) CLIA Kit for detecting Arg in serum, plasma, tissue homogenates
-
Analytische Methode
- Quantitative
-
Spezifität
- This assay has high sensitivity and excellent specificity for detection of Arginine (Arg). No significant cross-reactivity or interference between Arginine (Arg) and analogues was observed.
-
Sensitivität
- 146.9 ng/mL
-
Bestandteile
-
- Pre-coated, ready to use 96-well strip plate
- Standar
- Detection Reagent A
- Detection Reagent B
- Substrate A
- Substrate B
- Assay Diluent A
- Assay Diluent B
- Wash Buffer (30x concentrate)
- Standard Diluent
- Plate Sealer
- Instruction Manual
-
Benötigtes Material
-
- Microplate Reader with 450 nm filter
- Single or multi-channel pipettes with high precision and disposable tips
- Microcentrifuge tubes
- Deionized or distilled watter
- Absorbent paper for blotting the microplate
- Container for wash solution
- 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
-
-
-
-
Applikationshinweise
- Optimal working dilution should be determined by the investigator.
-
Kommentare
-
This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.
-
Probenmenge
- 50 μL
-
Testdauer
- 2 h
-
Plattentyp
- Pre-coated
-
Protokoll
- The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Arginine (Arg). A competitive inhibition reaction is launched between biotin labeled Arginine (Arg) and unlabeled Arginine (Arg) (Standards or samples) with the pre-coated antibody specific to Arginine (Arg). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Arginine (Arg) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Arginine (Arg) level in the sample or standard.
-
Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Arginine (Arg) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Arginine (Arg) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% -
Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
-
-
Handhabung
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Lagerung
- 4 °C,-20 °C
-
Informationen zur Lagerung
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Haltbarkeit
- 12 months
-
-
- Arginine (ARG)
-
Andere Bezeichnung
- Arginine
-
Substanzklasse
- Amino Acid
-
Hintergrund
- Gene Aliases: (S)-2-Amino-5-Guanidinopentanoic Acid
Target Alle Arginine (ARG) CLIA Kits anzeigen
-