CAMP ELISA Kit
Kurzübersicht für CAMP ELISA Kit (ABIN4881300)
Target
Alle CAMP (cAMP) ELISA Kits anzeigenReaktivität
Nachweismethode
Methodentyp
Detektionsbereich
Applikation
Proben
-
-
Untere Nachweisgrenze
- 0.1 ng/mL
-
Verwendungszweck
- cAMP EIA Kit optimized for serum and plasma samples. Competition-based ELISA on a 96-well strip plate.
-
Analytische Methode
- Quantitative
-
Spezifität
- This EIA kit is designed to only detect Cyclic AMP.
-
Sensitivität
- 4.4 ng/mL
-
Produktmerkmale
-
- Strip plates and additional reagents allow for use in multiple experiments
- Quantitative protein detection
- Establishes normal range
- The best products for confirmation of antibody array data
-
Bestandteile
-
- Pre-Coated 96-well Strip Microplate
- Wash Buffer
- Standard Peptide
- Assay Diluent(s)
- Biotinylated Peptide
- HRP-Streptavidin
- TMB One-Step Substrate
- Stop Solution
- Assay Diagram
- Positive Control Sample
- Capture Antibody
- User Manual
-
Benötigtes Material
-
- Distilled or deionized water
- Precision pipettes to deliver 2 μL to 1 mL volumes
- Adjustable 1-25 mL pipettes for reagent preparation
- 100 mL and 1 liter graduated cylinders
- Tubes to prepare standard and sample dilutions
- Orbital shaker
- Aluminum foil
- Saran Wrap
- Absorbent paper
- Microplate reader capable of measuring absorbance at 450nm
- SigmaPlot software (or other software that can perform four-parameter logistic regression models)
-
-
-
-
Probenmenge
- 100 μL
-
Plattentyp
- Pre-coated
-
Protokoll
-
- Prepare all reagents, samples and standards as instructed.
- Add 100 μL detection antibody to each well.
- Incubate 1.5 h at RT or O/N at 4 °C.
- Add 100 μL standard or sample to each well.
- Incubate 2.5 h at RT.
- Add 100 μL prepared streptavidin solution.
- Incubate 45 min at RT.
- Add 100 μL TMB One-Step Substrate Reagent to each well.
- Incubate 30 min at RT.
- Add 50 μL Stop Solution to each well.
- Read plate at 450 nm immediately.
-
Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
-
-
Lagerung
- -20 °C
-
Informationen zur Lagerung
- Standard, Biotinylated cAMP peptide, and Positive Control should be stored at -20°C after arrival. Avoid multiple freeze-thaws. The remaining kit components may be stored at 4°C. Opened Microplate Wells and antibody (Item N) may be stored for up to 1 month at 2° to 8°C. Return unused wells to the pouch containing desiccant pack and reseal along entire edge.
-
Haltbarkeit
- 6 months
-
-
- CAMP (cAMP) (Cyclic Adenosine Monophosphate (cAMP))
-
Andere Bezeichnung
- cAMP, Cyclic AMP
-
Substanzklasse
- Chemical
-
Pathways
- Cellular Response to Molecule of Bacterial Origin
Target Alle CAMP (cAMP) ELISA Kits anzeigen
-