Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

ICAM1 ELISA Kit

Ratte ICAM1 ELISA Kit, Colorimetric Assay für die Quantifizierung von Ratte ICAM1 und es wurde in 14+ Publikationen zitiert.
Produktnummer ABIN431356
548,78 €
Zzgl. Versandkosten 20,00 € und MwSt
Lieferung nach: Deutschland
Lieferung in 11 bis 15 Werktagen

Kurzübersicht für ICAM1 ELISA Kit (ABIN431356)

Target

Alle ICAM1 ELISA Kits anzeigen
ICAM1 (Intercellular Adhesion Molecule 1 (ICAM1))

Reaktivität

  • 33
  • 22
  • 22
  • 8
  • 5
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 1
Ratte

Nachweismethode

Colorimetric

Methodentyp

Sandwich ELISA

Detektionsbereich

0.312 ng/mL - 20 ng/mL

Applikation

ELISA

Proben

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
  • Untere Nachweisgrenze

    0.312 ng/mL

    Verwendungszweck

    The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of ICAM1 in Serum,Plasma,Tissue Homogenate,Cell Lysate,Cell Culture Supernatant,Biological Fluids

    Analytische Methode

    Quantitative

    Spezifität

    This assay has high sensitivity and excellent specificity for detection of Intercellular Adhesion Molecule 1 (ICAM1).
    No significant cross-reactivity or interference between Intercellular Adhesion Molecule 1 (ICAM1) and analogues was observed.

    Kreuzreaktivität (Details)

    No significant cross-reactivity or interference between Intercellular Adhesion Molecule 1 (ICAM1) and analogues was observed.

    Sensitivität

    < 0.127 ng/mL

    Bestandteile

    • Pre-coated, 96-well strip plate
    • Plate sealer
    • Standard
    • Standard Diluent
    • Detection Reagent A
    • Assay Diluent A
    • Detection Reagent B
    • Assay Diluent B
    • TMB Substrate
    • Stop Solution
    • Wash Buffer (30X)
    • Instruction manual

    Benötigtes Material

    • Microplate reader with 450 nm filter.
    • Precision single or multi-channel pipettes and disposable tips.
    • Eppendorf Tubes for diluting samples.
    • Deionized or distilled water.
    • Absorbent paper for blotting the microtiter plate.
    • Container for Wash Solution
  • Applikationshinweise

    • Limited by the current condition and scientific technology, we cannot completely conduct the comprehensive identification and analysis on the raw material provided by suppliers. So there might be some qualitative and technical risks to use the kit.
    • The final experimental results will be closely related to validity of the products, operation skills of the end users and the experimental environments. Please make sure that sufficient samples are available.
    • Kits from different batches may be a little different in detection range, sensitivity and color developing time.
    • Do not mix or substitute reagents from one kit lot to another. Use only the reagents supplied by manufacturer.
    • Protect all reagents from strong light during storage and incubation. All the bottle caps of reagents should be covered tightly to prevent the evaporation and contamination of microorganism.
    • There may be some foggy substance in the wells when the plate is opened at the first time. It will not have any effect on the final assay results. Do not remove microtiter plate from the storage bag until needed.
    • Wrong operations during the reagents preparation and loading, as well as incorrect parameter setting for the plate reader may lead to incorrect results. A microplate plate reader with a bandwidth of 10nm or less and an optical density range of 0-3 O.D. or greater at 450 ± 10nm wavelength is acceptable for use in absorbance measurement. Please read the instruction carefully and adjust the instrument prior to the experiment.
    • Even the same operator might get different results in two separate experiments. In order to get better reproducible results, the operation of every step in the assay should be controlled. Furthermore, a preliminary experiment before assay for each batch is recommended.
    • Each kit has been strictly passed Q.C test. However, results from end users might be inconsistent with our in-house data due to some unexpected transportation conditions or different lab equipments. Intra-assay variance among kits from different batches might arise from above factors, too.
    • Kits from different manufacturers for the same item might produce different results, since we have not compared our products with other manufacturers.

    Kommentare

    Information on standard material:
    The standard might be recombinant protein or natural protein, that will depend on the specific kit. Moreover, the expression system is E.coli or yeast or mammal cell. There is 0.05% proclin 300 in the standard as preservative.

    Information on reagents:
    The stop solution used in the kit is sulfuric acid with concentration of 1 mol/L. And the wash solution is TBS. The standard diluent contains 0.02 % sodium azide, assay diluent A and assay diluent B contain 0.01% sodium azide. Some kits can contain is BSA in them.

    Information on antibodies:
    The provided antibodies and their host vary in different kits.

    Probenmenge

    100 μL

    Testdauer

    3 h

    Plattentyp

    Pre-coated

    Protokoll

    1. Prepare all reagents, samples and standards;
    2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C;
    3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
    4. Aspirate and wash 3 times;
    5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
    6. Aspirate and wash 5 times;
    7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
    8. Add 50µL Stop Solution. Read at 450nm immediately.

    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Intercellular Adhesion Molecule 1 (ICAM1) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Intercellular Adhesion Molecule 1 (ICAM1) were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Vorsichtsmaßnahmen

    The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.

    Handhabung

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Lagerung

    4 °C

    Informationen zur Lagerung

    • For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
    • For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
      Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.
    • For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.

    Haltbarkeit

    6 months
  • Huang, Lu, Yang, Liu, Qin, Li: "Cellular Metabolomics Reveal the Mechanism Underlying the Anti-Atherosclerotic Effects of Aspirin Eugenol Ester on Vascular Endothelial Dysfunction." in: International journal of molecular sciences, Vol. 20, Issue 13, (2019) (PubMed).

    Elkhoely, Kamel: "Diallyl sulfide alleviates cisplatin-induced nephrotoxicity in rats via suppressing NF-κB downstream inflammatory proteins and p53/Puma signalling pathway." in: Clinical and experimental pharmacology & physiology, Vol. 45, Issue 6, pp. 591-601, (2018) (PubMed).

    Wang, Ying, Jiang, Jin, Kuang, Zhang, Shi, Cai, Yang: "Aspirin modulates the inflammatory response in a thrombus‑stimulated LMVEC model." in: International journal of molecular medicine, Vol. 41, Issue 6, pp. 3253-3266, (2018) (PubMed).

    Alexandropoulos, Bazigos, Doulamis, Tzani, Konstantopoulos, Tragotsalou, Kondi-Pafiti, Kotsis, Arkadopoulos, Smyrniotis, Perrea: "Protective effects of N-acetylcystein and atorvastatin against renal and hepatic injury in a rat model of intestinal ischemia-reperfusion." in: Biomedicine & pharmacotherapy, Vol. 89, pp. 673-680, (2017) (PubMed).

    Das, Hamsi, Kamisah, Qodriyah, Othman, Emran, Zakaria, Jaarin: "Changes in blood pressure, vascular reactivity and inflammatory biomarkers following consumption of heated corn oil." in: Pakistan journal of pharmaceutical sciences, Vol. 30, Issue 5, pp. 1609-1615, (2017) (PubMed).

    Wang, Liu, Pan, Bai, Chen: "Global gene expression profile of cerebral ischemia-reperfusion injury in rat MCAO model." in: Oncotarget, Vol. 8, Issue 43, pp. 74607-74622, (2017) (PubMed).

    Motawi, Darwish, Hamed, El-Rigal, Naser: "A Therapeutic Insight of Niacin and Coenzyme Q10 Against Diabetic Encephalopathy in Rats." in: Molecular neurobiology, (2016) (PubMed).

    Lan, Zheng, Yang, Ji, Fan, Zeng: "Peroxisome proliferator-activated receptor-? agonist pioglitazone ameliorates white matter lesion and cognitive impairment in hypertensive rats." in: CNS neuroscience & therapeutics, Vol. 21, Issue 5, pp. 410-6, (2015) (PubMed).

    Chen, Zhang, Ge, Tseng, Bai, Qu, Beer, Autrup, Chen: "Subchronic toxicity and cardiovascular responses in spontaneously hypertensive rats after exposure to multiwalled carbon nanotubes by intratracheal instillation." in: Chemical research in toxicology, Vol. 28, Issue 3, pp. 440-50, (2015) (PubMed).

    Dong, Ren, Wang, Jiang, Yin, Wang, Wang, Feng: "Allopurinol reduces severity of delayed neurologic sequelae in experimental carbon monoxide toxicity in rats." in: Neurotoxicology, Vol. 48, pp. 171-9, (2015) (PubMed).

    Wu, Zhang, Hu, Yan, Xie, Wu: "Inflammatory response and neuronal necrosis in rats with cerebral ischemia." in: Neural regeneration research, Vol. 9, Issue 19, pp. 1753-62, (2014) (PubMed).

    Tan, Wang, Guo, Gui, Wang: "Preventive Effects of a Natural Anti-Inflammatory Agent, Astragaloside IV, on Ischemic Acute Kidney Injury in Rats." in: Evidence-based complementary and alternative medicine : eCAM, Vol. 2013, pp. 284025, (2013) (PubMed).

    Gui, Huang, Guo, Chen, Chen, Xiao, Liu, Wang: "Astragaloside IV ameliorates renal injury in streptozotocin-induced diabetic rats through inhibiting NF-?B-mediated inflammatory genes expression." in: Cytokine, Vol. 61, Issue 3, pp. 970-7, (2013) (PubMed).

    Foxx, Plaska, Bittle: "Guidelines for the use of contingent electric shock to treat aberrant behavior." in: Progress in behavior modification, Vol. 20, pp. 1-34, (1986) (PubMed).

  • Target Alle ICAM1 ELISA Kits anzeigen

    ICAM1 (Intercellular Adhesion Molecule 1 (ICAM1))

    Andere Bezeichnung

    ICAM1

    Substanzklasse

    Viral Protein

    Hintergrund

    CD54, BB2, P3.58, Human Rhinovirus Receptor, Major group rhinovirus receptor

    UniProt

    Q00238

    Pathways

    Cellular Response to Molecule of Bacterial Origin, Regulation of Actin Filament Polymerization, Carbohydrate Homeostasis, Regulation of Leukocyte Mediated Immunity, Thromboxane A2 Receptor Signaling
Sie sind hier:
Chat with us!