AP36 ELISA Kit

Das Human AP36 ELISA Kit (ABIN414855) ist ein Colorimetric ELISA Kit zur Detektion von Human AP36. Das Kit wurde in 6 Publikationen zitiert.
Produktnummer ABIN414855
812,78 €
Zzgl. Versandkosten 20,00 € und MwSt
Lieferung nach: Deutschland
Lieferung in 11 bis 15 Werktagen

Kurzübersicht für AP36 ELISA Kit (ABIN414855)

Target

Alle AP36 ELISA Kits anzeigen
AP36 (Apelin 36 (AP36))

Reaktivität

  • 12
  • 5
  • 3
Human

Nachweismethode

Colorimetric

Methodentyp

Competition ELISA

Detektionsbereich

7.41 pg/mL - 600 pg/mL

Applikation

ELISA

Proben

Plasma, Serum
  • Untere Nachweisgrenze

    7.41 pg/mL

    Verwendungszweck

    The kit is a competitive inhibition enzyme immunoassay technique for the in vitro quantitative measurement of AP36 in Serum,Plasma,Biological Fluids

    Analytische Methode

    Quantitative

    Spezifität

    This assay has high sensitivity and excellent specificity for detection of Apelin 36 (AP36).
    No significant cross-reactivity or interference between Apelin 36 (AP36) and analogues was observed.

    Kreuzreaktivität (Details)

    No significant cross-reactivity or interference between Apelin 36 (AP36) and analogues was observed.

    Sensitivität

    < 2.52 pg/mL

    Bestandteile

    • Pre-coated, 96-well strip plate
    • Plate sealer
    • Standard
    • Standard Diluent
    • Detection Reagent A
    • Assay Diluent A
    • Detection Reagent B
    • Assay Diluent B
    • TMB Substrate
    • Stop Solution
    • Wash Buffer (30X)
    • Instruction manual

    Benötigtes Material

    • Microplate reader with 450 nm filter.
    • Precision single or multi-channel pipettes and disposable tips.
    • Eppendorf Tubes for diluting samples.
    • Deionized or distilled water.
    • Absorbent paper for blotting the microtiter plate.
    • Container for Wash Solution
  • Applikationshinweise

    • Limited by the current condition and scientific technology, we cannot completely conduct the comprehensive identification and analysis on the raw material provided by suppliers. So there might be some qualitative and technical risks to use the kit.
    • The final experimental results will be closely related to validity of the products, operation skills of the end users and the experimental environments. Please make sure that sufficient samples are available.
    • Kits from different batches may be a little different in detection range, sensitivity and color developing time.
    • Do not mix or substitute reagents from one kit lot to another. Use only the reagents supplied by manufacturer.
    • Protect all reagents from strong light during storage and incubation. All the bottle caps of reagents should be covered tightly to prevent the evaporation and contamination of microorganism.
    • There may be some foggy substance in the wells when the plate is opened at the first time. It will not have any effect on the final assay results. Do not remove microtiter plate from the storage bag until needed.
    • Wrong operations during the reagents preparation and loading, as well as incorrect parameter setting for the plate reader may lead to incorrect results. A microplate plate reader with a bandwidth of 10nm or less and an optical density range of 0-3 O.D. or greater at 450 ± 10nm wavelength is acceptable for use in absorbance measurement. Please read the instruction carefully and adjust the instrument prior to the experiment.
    • Even the same operator might get different results in two separate experiments. In order to get better reproducible results, the operation of every step in the assay should be controlled. Furthermore, a preliminary experiment before assay for each batch is recommended.
    • Each kit has been strictly passed Q.C test. However, results from end users might be inconsistent with our in-house data due to some unexpected transportation conditions or different lab equipments. Intra-assay variance among kits from different batches might arise from above factors, too.
    • Kits from different manufacturers for the same item might produce different results, since we have not compared our products with other manufacturers.

    Kommentare

    Information on standard material:
    The standard might be recombinant protein or natural protein, that will depend on the specific kit. Moreover, the expression system is E.coli or yeast or mammal cell. There is 0.05% proclin 300 in the standard as preservative.

    Information on reagents:
    The stop solution used in the kit is sulfuric acid with concentration of 1 mol/L. And the wash solution is TBS. The standard diluent contains 0.02 % sodium azide, assay diluent A and assay diluent B contain 0.01% sodium azide. Some kits can contain is BSA in them.

    Information on antibodies:
    The provided antibodies and their host vary in different kits.

    Probenmenge

    50 μL

    Testdauer

    2 h

    Plattentyp

    Pre-coated

    Protokoll

    1. Prepare all reagents, samples and standards;
    2. Add 50µL standard or sample to each well.
        And then add 50µL prepared Detection Reagent A immediately.
        Shake and mix. Incubate 1 hour at 37°C;
    3. Aspirate and wash 3 times;
    4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
    5. Aspirate and wash 5 times;
    6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
    7. Add 50µL Stop Solution. Read at 450 nm immediately.

    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Apelin 36 (AP36) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Apelin 36 (AP36) were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Vorsichtsmaßnahmen

    The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.

    Handhabung

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Lagerung

    4 °C

    Informationen zur Lagerung

    • For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
    • For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
      Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.
    • For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.

    Haltbarkeit

    6 months
  • Shi, Bielecka-Dabrowa, Mynbaev, Wei: "Find the Essence through the Phenomena: Cardiovascular Diseases and Biomarkers." in: Disease markers, Vol. 2018, pp. 1929106, (2019) (PubMed).

    Cano Martínez, Coral Vázquez, Méndez, Trejo, Pérez Razo, Canto: "Serum concentrations of apelin-17 isoform vary in accordance to blood pressure categories in individuals with obesity class 3." in: Clinical and experimental hypertension (New York, N.Y. : 1993), pp. 1-6, (2018) (PubMed).

    Salska, Dziuba, Salski, Chizynski, Zielinska: "Apelin and Atrial Fibrillation: The Role in the Arrhythmia Recurrence Prognosis." in: Disease markers, Vol. 2018, pp. 5285392, (2018) (PubMed).

    Duman, Bahçeci, Hamur, Demirelli, Ramazan Dilek, Erdogan, Duman, Şatıroğlu, Durakoğlugil: "The Relationship between Serum Apelin Levels and the Severity of Calcific Aortic Stenosis." in: Acta Cardiologica Sinica, Vol. 34, Issue 3, pp. 259-266, (2018) (PubMed).

    Altinkaya, Nergiz, Küçük, Yüksel: "Apelin levels are higher in obese patients with endometrial cancer." in: The journal of obstetrics and gynaecology research, Vol. 41, Issue 2, pp. 294-300, (2015) (PubMed).

    Altinkaya, Nergiz, Küçük, Yüksel: "Apelin levels in relation with hormonal and metabolic profile in patients with polycystic ovary syndrome." in: European journal of obstetrics, gynecology, and reproductive biology, Vol. 176, pp. 168-72, (2014) (PubMed).

  • Target Alle AP36 ELISA Kits anzeigen

    AP36 (Apelin 36 (AP36))

    Andere Bezeichnung

    Apelin 36

    Hintergrund

    APLN36

    UniProt

    Q9ULZ1
Sie sind hier: