Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

HMOX1 ELISA Kit

HMOX1 Reaktivität: Ratte Colorimetric Sandwich ELISA 0.312-20 ng/mL Plasma, Serum, Tissue Homogenate
Produktnummer ABIN368210
  • Target Alle HMOX1 ELISA Kits anzeigen
    HMOX1 (Heme Oxygenase (Decycling) 1 (HMOX1))
    Reaktivität
    • 6
    • 3
    • 3
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Ratte
    Nachweismethode
    Colorimetric
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    0.312-20 ng/mL
    Untere Nachweisgrenze
    0.312 ng/mL
    Applikation
    ELISA
    Verwendungszweck
    This assay employs the quantitative sandwich enzyme immunoassay technique.
    Proben
    Serum, Plasma, Tissue Homogenate
    Analytische Methode
    Quantitative
    Spezifität
    This assay has high sensitivity and excellent specificity for detection of Rat HMOX1.
    Kreuzreaktivität (Details)
    Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between the target antigen and all analogues for other species. Therefore, cross reaction may still exist.
    Sensitivität
    0.078 ng/mL
    Bestandteile
    • Assay plate (12 × 8 coated Microwells)
    • Standard (freeze dried)
    • Biotin-antibody (100 × concentrate)
    • HRP-avidin (100 × concentrate)
    • Biotin-antibody Diluent
    • HRP-avidin Diluent
    • Sample Diluent
    • Wash Buffer (25 × concentrate)
    • TMB Substrate
    • Stop Solution
    • Adhesive Strip (for 96 wells)
    • Instruction manual
    Featured
    Zu unserem meistverkauften HMOX1 ELISA Kit
    Top Product
    Discover our top product HMOX1 ELISA Kit
  • Applikationshinweise
    • The supplier is only responsible for the kit itself, but not for the samples consumed during the assay. The user should calculate the possible amount of the samples used in the whole test. Please reserve sufficient samples in advance.
    • Samples to be used within 5 days may be stored at 2-8°C, otherwise samples must be stored at -20°C (≤ 1 month) or -80°C (≤ 2 months) to avoid loss of bioactivity and contamination.
    • Grossly hemolyzed samples are not suitable for use in this assay.
    • If the samples are not indicated in the manual, a preliminary experiment to determine the validity of the kit is necessary.
    • Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their particular experiments.
    • Tissue or cell extraction samples prepared by chemical lysis buffer may cause unexpected ELISA results due to the impacts of certain chemicals.
    • Owing to the possibility of mismatching between antigens from another resource and antibodies used in this supplier's kits (e.g., antibody targets conformational epitope rather than linear epitope), some native or recombinant proteins from other manufacturers may not be recognized by this supplier's products.
    • Influenced by factors including cell viability, cell number and cell sampling time, samples from cell culture supernatant may not be recognized by the kit.
    • Fresh samples without long time storage are recommended for the test. Otherwise, protein degradation and denaturalization may occur in those samples and finally lead to wrong results.
    Kommentare

    Detection wavelength: 450 nm

    Information on standard material:
    Depending on the antigen to be detected, standards can be either native or recombinant protein. The recombinant proteins are being expressed in CHO cells in most cases. Please inquire for more information. The formulation of auxiliary material in the standard is considered proprietary information, however it does not contain any poisonous substance. Proclin 300 (1:3000) is used as preservative.

    Information on reagents:
    In most cases the stop solution provided is 1 N H2SO4. The formulation of wash solution is proprietary information. None of the components contain (sodium) azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials. For the sandwich method kits, the sample diluent, antibody diluent, enzyme diluent and standard all contain BSA.

    Information on antibodies:
    The antibodies provided in different kits vary in regards to clonality and host. Some antibodies are affinity purified, some are Protein A

    Probenmenge
    100 μL
    Testdauer
    1 - 4.5 h
    Plattentyp
    Pre-coated
    Protokoll
    Antibody specific for HMOX1 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any HMOX1 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for HMOX1 is added to the wells. After washing, avidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of HMOX1 bound in the initial step. The color development is stopped and the intensity of the color is measured.
    Aufbereitung der Reagenzien
    • Biotin-antibody (1×) - Centrifuge the vial before opening.
      Biotin-antibody requires a 100-fold dilution. The suggested dilution is 10µL of Biotin-antibody + 990µL of Biotin-antibody Diluent.
    • HRP-avidin (1×) - Centrifuge the vial before opening.
      HRP-avidin requires a 100-fold dilution. The suggested dilution is 10µL of HRP-avidin + 990µL of HRP-avidin Diluent.
    • Wash Buffer (1×) - If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have completely dissolved. Dilute 20mL of Wash Buffer Concentrate (25×) into deionized or distilled water to prepare 500mL of Wash Buffer (1×).
    • Standard - Centrifuge the standard vial at 6000-10000rpm for 30s.
      Reconstitute the Standard with 1ml of Sample Diluent. Do not substitute other diluents. This reconstitution produces a stock solution. Mix the standard to ensure complete reconstitution and allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making dilutions.
      Pipette 250µL of Sample Diluent into each tube. Use the stock solution to produce a 2-fold dilution series. Mix each tube thoroughly before the next transfer. The undiluted Standard serves as the high standard. Sample Diluent serves as the zero standard (0ng/mL).
    Note:
    • Kindly use graduated containers to prepare the reagent. Please don't prepare the reagent directly in the Diluent vials provided in the kit.
    • Bring all reagents to room temperature (18-25°C) before use for 30 min.
    • Prepare fresh standard for each assay. Use within 4 hours and discard after use.
    • Making serial dilution in the wells directly is not permitted.
    • Please carefully reconstitute Standards according to the instruction. Avoid foaming and mix gently until the crystals have completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10µL when pipetting.
    • It is recommended to use distilled water to prepare reagents and samples. Using contaminated water or container for reagent preparation will influence detection result.
    Testpräzision
    Intra-assay precision (precision within an assay): Three samples of known concentration were tested twenty times on one plate to assess precision.
    Inter-assay precision (precision between assays): Three samples of known concentration were tested in twenty assays to assess precision.
    • Intra-assay: CV% less than 8%
    • Inter-assay: CV% less than 10%
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Vorsichtsmaßnahmen
    The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face and clothing protection when using this material.
    Handhabung
    • The kit should not be used beyond the expiration date on the kit label.
    • Do not mix or substitute reagents with those from other lots or sources.
    • If samples generate values higher than the highest standard, dilute the samples with Sample Diluent and repeat the assay.
    • Any variation in Sample Diluent, operator, pipetting technique, washing technique, incubation time/temperature and kit age can cause variation in binding.
    • This assay is designed to eliminate interference by soluble receptors, binding proteins and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
    Lagerung
    4 °C/-20 °C
    Informationen zur Lagerung
    For unopened kit: All the reagents should be kept according to the labels on vials.
    Haltbarkeit
    6 months
  • Yan, Wang, Wu, Wang, Li, Liang, Wu: "Zinc oxide nanoparticle-induced atherosclerotic alterations in vitro and in vivo." in: International journal of nanomedicine, Vol. 12, pp. 4433-4442, (2017) (PubMed).

    Bhardwaj, Deshmukh, Kaundal, Krishna Reddy: "Pharmacological induction of hemeoxygenase-1 activity attenuates intracerebroventricular streptozotocin induced neurocognitive deficit and oxidative stress in rats." in: European journal of pharmacology, Vol. 772, pp. 43-50, (2016) (PubMed).

    Khan, Jamwal, Bijjem, Prakash, Kumar: "Neuroprotective effect of hemeoxygenase-1/glycogen synthase kinase-3? modulators in 3-nitropropionic acid-induced neurotoxicity in rats." in: Neuroscience, Vol. 287C, pp. 66-77, (2015) (PubMed).

    Bijjem, Padi, lal Sharma: "Pharmacological activation of heme oxygenase (HO)-1/carbon monoxide pathway prevents the development of peripheral neuropathic pain in Wistar rats." in: Naunyn-Schmiedeberg's archives of pharmacology, Vol. 386, Issue 1, pp. 79-90, (2013) (PubMed).

  • Target Alle HMOX1 ELISA Kits anzeigen
    HMOX1 (Heme Oxygenase (Decycling) 1 (HMOX1))
    Andere Bezeichnung
    heme oxygenase 1 (HO-1) (HMOX1 Produkte)
    Synonyme
    HMOX1 ELISA Kit, ARABIDOPSIS THALIANA HEME OXYGENASE 1 ELISA Kit, ATHO1 ELISA Kit, F18A8.4 ELISA Kit, F18A8_4 ELISA Kit, GENOMES UNCOUPLED 2 ELISA Kit, GUN2 ELISA Kit, HEME OXYGENASE ELISA Kit, HEME OXYGENASE 1 ELISA Kit, HEME OXYGENASE 6 ELISA Kit, HO1 ELISA Kit, HY1 ELISA Kit, HY6 ELISA Kit, PLASTID HEME OXYGENASE ELISA Kit, REVERSAL OF THE DET PHENOTYPE 4 ELISA Kit, HO-1 ELISA Kit, wu:fc27c04 ELISA Kit, zgc:65984 ELISA Kit, D8Wsu38e ELISA Kit, Hemox ELISA Kit, Hmox ELISA Kit, Hsp32 ELISA Kit, HEOXG ELISA Kit, Heox ELISA Kit, Ho-1 ELISA Kit, Ho1 ELISA Kit, hsp32 ELISA Kit, MGC132176 ELISA Kit, Hmox1 ELISA Kit, HMOX1D ELISA Kit, HSP32 ELISA Kit, bK286B10 ELISA Kit, heme oxygenase 1 ELISA Kit, Plant heme oxygenase (decyclizing) family protein ELISA Kit, Heme oxygenase ELISA Kit, heme oxygenase ELISA Kit, heme oxygenase 1, chloroplastic ELISA Kit, heme oxygenase 1a ELISA Kit, heme oxygenase 1 L homeolog ELISA Kit, HMOX1 ELISA Kit, TED4 ELISA Kit, ho1 ELISA Kit, P9301_RS17555 ELISA Kit, A9601_RS17590 ELISA Kit, MAE_RS06565 ELISA Kit, HO1 ELISA Kit, hmox1a ELISA Kit, CPE0214 ELISA Kit, Cyan7425_2962 ELISA Kit, Hmox1 ELISA Kit, hmox1.L ELISA Kit, AM1_C0205 ELISA Kit, CC1G_11686 ELISA Kit, CpipJ_CPIJ007246 ELISA Kit
    Hintergrund
    Synonyms: HO-1, HSP32, bK286B10, heme oxygenase (decyclizing) 1
    HGNC
    5013
    UniProt
    P06762
    Pathways
    Transition Metal Ion Homeostasis, Regulation of Leukocyte Mediated Immunity, Positive Regulation of Immune Effector Process, Production of Molecular Mediator of Immune Response, SARS-CoV-2 Protein Interaktom
Sie sind hier:
Kundenservice