Etanercept specific ELISA Kit

Reaktivität: Chemical, Human Colorimetric Sandwich ELISA 0.2-6 μg/mL Plasma (EDTA - heparin), Serum
Produktnummer ABIN2862656
  • Target
    Etanercept specific
    Reaktivität
    Chemical, Human
    Nachweismethode
    Colorimetric
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    0.2-6 μg/mL
    Untere Nachweisgrenze
    0.2 μg/mL
    Applikation
    ELISA
    Verwendungszweck
    Enzyme immunoassay for the specific and quantitative determination of free Etanercept in human serum and plasma.
    Marke
    ImmunoGuide®
    Proben
    Serum, Plasma (EDTA - heparin)
    Analytische Methode
    Quantitative
    Spezifität
    Etanercept (Enbrel®), no cross reaction to any other TNF-a catchers. Here is no cross reaction with any other proteins present in native human serum and no cross reaction was observed with the other therapeutic antibodies including Infliximab, Adalimumab and Golimumab tested at concentrations up to 500 μg/mL.
    Sensitivität
    10 ng/mL
    Produktmerkmale
    0.2 - 6 µg/mL (in case of the recommended sample dilution factor)
    10 ng/ml (sensitivity in the well)
    This kit measures the free drug concentration without any cross reaction to other TNF-a catcher.
    Bestandteile
    • 1 x 12 x 8 Microtiter Plate Break apart strips coated with 5A1 mAb specific for Etanercept only.
    • 5 x 0.5 mL Etanercept Standards A-E 300, 100, 30, 10 and 0 ng/mL Ready to use. Used for construction of the standard curve. Contains Etanercept, Human Serum, Proteins, Stabilizer and <15mM NaN3.
    • 1 x 50 mL Assay Buffer Blue colored. Ready to use. Contains proteins and <15mM NaN3.
    • 1 x 12 mL Enzyme Conjugate Red colored. Ready to use. Contains horseradish peroxidase(HRP)-conjugated anti-human IgG mouse monoclonal antibody, Proclin® and stabilizers.
    • 1 x 12 mL TMB Substrate Solution Ready to use. Contains 3,3',5,5'-Tetramethylbenzidine (TMB).
    • 1 x 12 mL Stop Solution Ready to use. 1 N Hydrochloric acid (HCl).
    • 1 x 50 mL Wash Buffer, Concentrate (20x) Contains buffer, Tween® 20 and KathonTM.
    • 3 x 1 Adhesive Seal For sealing microtiter plate during incubation.
    Benötigtes Material
    • Micropipettes (< 3 % CV) and tips to deliver 5-1000 μL.
    • Bidistilled or deionised water and calibrated glasswares (e.g. flasks or cylinders).
    • Wash bottle, automated or semi-automated microtiter plate washing system.
    • Microtiter plate reader capable of reading absorbance at 450 nm (reference wavelength at 600-650 nm is optional).
    • Absorbent paper towels, standard laboratory glass or plastic vials, and a timer.
  • Applikationshinweise
    • Before performing the assay, samples and assay kit should be brought to room temperature (about 30 minutes beforehand) and ensure the homogeneity of the solution.
    • All Standards should be run with each series of unknown samples.
    • Standards should be subject to the same manipulations and incubation times as the samples being tested.
    • All steps of the test should be completed without interruption.
    • Use new disposable plastic pipette tips for each reagent, standard or specimen in order to avoid cross contamination.
    Kommentare

    Etanercept ELISA (mAb-based) is suitable also for using by an automated ELISA processor.

    Probenmenge
    20 μL
    Testdauer
    1.5 h
    Plattentyp
    Pre-coated
    Protokoll
    The Etanercept (mAb-based) ELISA is based on Etanercept- specific IG 5A1 monoclonal antibody (mAb). Standards and samples are incubated in the microtitre plate coated with 5A1 mAb. After incubation, the wells are washed. Anti-human IgG mAb (IG 1B5 clone) conjugated to horse radish peroxidase (HRP) is added and binds to the Fc part of Etanercept specifically captured by the 5A1 mAb on the surface of the wells. Following incubation, the wells are washed and the bound enzymatic activity is detected by addition of chromogen-substrate. The colour developed is proportional to the amount of Etanercept in the sample or standard. Results of samples can be determined directly by using the standard curve.
    Aufbereitung der Reagenzien

    Wash Buffer: Dilute 10 mL Wash Buffer (up to 200 mL) at the ratio of 1:20 with distilled water.
    Warm up at 37 °C to dissolve crystals. Mix vigorously.
    Store at 2-8 °C for up to 4 weeks.
    Prepare Wash Buffer before starting the assay procedure.

    Probennahme
    Normal serum or plasma collection
    Aufbereitung der Proben

    Serum/ Plasma: Initially dilute the Serum/ Plasma (Sample) at the ratio of 1:20 with Assay Buffer.
    Sample : Assay Buffer Relation can be 1:20-1:100.
    For dilution at 1:20, 10 μL Sample + 190 μL Assay Buffer
    For dilution at 1:100, 5 μL Sample + 495 μL Assay Buffer
    If any sample, initially diluted as indicated above, produces an OD value above the measuring range it should be rated as "> highest standard". The result should not be extrapolated. The sample in question should be further diluted with Assay Buffer and then retested.

    Serum, Plasma (EDTA, Heparin): The usual precautions for venipuncture should be observed. It is important to preserve the chemical integrity of a blood specimen from the moment it is collected until it is assayed. Do not use grossly hemolytic, icteric or grossly lipemic specimens. Samples appearing turbid should be centrifuged before testing to remove any particulate material.

    Storage: 2-8 °C &leq,-20 °C (Aliquots)
    Keep away from heat or direct sun light.
    Avoid repeated freeze-thaw cycles.
    Stability: 3 days at 2-8 °C, 6 months at -20 °C

    Testdurchführung
    1. Pipette 100 μL of Assay Buffer into each of the wells to be used.
    2. Pipette 20 μL of each Ready-to Use Standard, and Diluted Samples into the respective wells of microtiter plate. Wells A1: Standard A B1: Standard B C1: Standard C D1: Standard D E1: Standard E F1 and on: Diluted Samples (Serum/Plasma)
    3. Cover the plate with adhesive seal. Shake plate carefully. Incubate 30 min at room temperature (RT) (18-25 °C).
    4. Remove adhesive seal. Aspirate or decant the incubation solution. Wash the plate 3 X 300 μL of Diluted Wash Buffer per well. Remove excess solution by tapping the inverted plate on a paper towel.
    5. Pipette 100 μL of Enzyme Conjugate (HRP-anti human IgGFc 1B5 mAb) into each well.
    6. Cover plate with adhesive seal. Shake plate carefully. Incubate 30 min at RT.
    7. Remove adhesive seal. Aspirate or decant the incubation solution. Wash the plate 3 X 300 μL of Diluted Wash Buffer per well. Remove excess solution by tapping the inverted plate on a paper towel.
    8. Pipette 100 μL of Ready-to-Use TMB Substrate Solution into each well.
    9. Incubate 15 min at RT. Avoid exposure to direct sunlight.
    10. Stop the substrate reaction by adding 100 μL of Stop Solution into each well. Briefly mix contents by gently shaking the plate. Color changes from blue to yellow.
    11. Measure optical density (OD) with a photometer at 450 nm (Reference at OD620 nm is Optional) within 15 min after pipetting of the Stop Solution.
    Ergebnisberechnung

    A standard curve should be calculated using the standard concentration (X-axis) versus the OD450 (or OD450/620) values (Y-axis). This can be done manually using graph paper or with a computer program. Concerning the data regression by computer we are recommending to primarily use the "4 Parameter Logistic (4PL)" or alternatively the "point-to-point calculation". In case of manual plot there are 2 options: Semilog graph or linear graph . Semilog graph paper is available at http://www.papersnake.com/logarithmic/semilogarithmic/. The concentration of the samples can be read from this standard curve as follows. Using the absorbance value for each sample, determine the corresponding concentration of the drug from the standard curve. This value always has to be multiplied by the dilution factor. If any diluted sample is reading greater than the highest standard, it should be further diluted appropriately with Assay Buffer and retested. Also this second dilution has to be used for calculation the final result.

    Testpräzision
    Intra-assay CV: <10%.
    Inter-assay CV: <10%.

    Recovery rate was found to be 98-102% with native human serum and plasma samples when spiked with exogenous Etanercept at 0,6 μg/mL or 6 μg/mL.
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Buffer
    < 15mM NaN3
    Konservierungsmittel
    Sodium azide
    Vorsichtsmaßnahmen
    This product contains Sodium azide: a POISONOUS AND HAZARDOUS SUBSTANCE which should be handled by trained staff only.
    Lagerung
    4 °C
    Informationen zur Lagerung
    The kit is shipped at ambient temperature and should be stored at 2-8°C.
    Keep away from heat or direct sun light.
    The storage and stability of specimen and prepared reagents is stated in the corresponding chapters.
    The microtiter strips are stable up to the expiry date of the kit in the broken, but tightly closed bag when stored at 2-8°C.
    Haltbarkeit
    24 months
  • Target
    Etanercept specific
    Hintergrund
    Etanercept is a dimeric fusion protein consisting of the extracellular ligand-binding portion of the human 75 kilodalton (p75) tumor necrosis factor receptor (TNFR) linked to the Fc portion of human IgG1. Etanercept binds specifically to human tumor necrosis factor alpha (TNF-α) and blocks its interaction with cell surface TNF receptors. Serum concentration of Etanercept might be related to predict some clinical outcome during maintenance therapy. It was also possible that the surveillance of circulating Etanercept concentration during maintenence therapy represents a direct and/or indirect factor for immunogenicity and some other side effects. In this context, identification of biomarkers for (non-)response and risk factors for adverse drug reactions that might be related to serum concentrations and maintaining the effective concentration of Etanercept in order to potentially avoid some side effects with a reliable method might be beneficial.
    Molekulargewicht
    51 kDa