Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

OLR1 ELISA Kit

Das Human OLR1 ELISA Kit (ABIN1672809) ist ein Colorimetric ELISA Kit zur Detektion von Human OLR1. Das Kit wurde in 1 Publikation zitiert.
Produktnummer ABIN1672809
642,40 €
Zzgl. Versandkosten 20,00 € und MwSt
96 tests
Lieferung nach: Deutschland
Lieferung in 8 bis 12 Werktagen

Kurzübersicht für OLR1 ELISA Kit (ABIN1672809)

Target

Alle OLR1 ELISA Kits anzeigen
OLR1 (Oxidized Low Density Lipoprotein (Lectin-Like) Receptor 1 (OLR1))

Bindungsspezifität

AA 61-273

Reaktivität

  • 16
  • 15
  • 8
  • 6
  • 5
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Human

Nachweismethode

Colorimetric

Methodentyp

Sandwich ELISA

Detektionsbereich

31.2 pg/mL - 2000 pg/mL

Applikation

ELISA

Proben

Cell Culture Supernatant, Cell Lysate, Plasma (EDTA), Plasma (heparin), Serum
  • Untere Nachweisgrenze

    31.2 pg/mL

    Verwendungszweck

    Sandwich Human LOX-1/OLR1 ELISA Kit to quantitate Human OLR1 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

    Analytische Methode

    Quantitative

    Spezifität

    Expression system for standard: NS0
    Immunogen sequence: S61-Q273

    Capture antibody and Detection antibody: monoclonal antibody from mouse, polyclonal antibody from goat

    Kreuzreaktivität (Details)

    There is no detectable cross-reactivity with other relevant proteins.

    Sensitivität

    < 10 pg/mL

    Bestandteile

    1. Pre-coated 96-well strip microplate
    2. Standard
    3. Biotinylated antibody (100x)
    4. Avidin-Biotin-Peroxidase Complex (100x)
    5. Sample Diluent
    6. Antibody Diluent
    7. Avidin-Biotin-Peroxidase Diluent
    8. Color Developing Reagent (TMB)
    9. Stop Solution
    10. Wash Buffer (25x)
    11. Adhesive plate sealers

    Benötigtes Material

    Microplate Reader capable of reading absorbance at 450nm. Incubator. Automated plate washer (optional). Pipettes and pipette tips capable of precisely dispensing 0.5 μL through 1 mL volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500 mL graduated cylinders. Test tubes for dilution.
  • Applikationshinweise

    Before using Kit, spin tubes and bring down all components to bottom of tube. Duplicate well assay was recommended for both standard and sample testing.

    Probenmenge

    100 μL

    Plattentyp

    Pre-coated

    Protokoll

    ELISA Kit is based on standard sandwich enzyme-linked immune-sorbent assay technology. An antibody has been precoated onto 96-well plates. Standards and test samples are added to the wells, a biotinylated detection antibody specific for target is added subsequently and then followed by washing with PBS or TBS buffer. Avidin-Biotin-Peroxidase Complex was added and unbound conjugates were washed away with PBS or TBS buffer. HRP substrate TMB was used to visualize HRP enzymatic reaction. TMB was catalyzed by HRP to produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional to the target amount in sample captured in plate.

    Testpräzision

    Intra-Assay Precision (CV%): 7.8%, 5.7%, 7.7%
    Inter-Assay Precision (CV%): 9.4%, 5.7%, 8.9%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Handhabung

    Avoid multiple freeze-thaw cycles.

    Lagerung

    -20 °C,4 °C

    Informationen zur Lagerung

    Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

    Haltbarkeit

    12 months
  • Gao, Xie, Kong, Liu, Sun, Xiong, Huang, Yan, Sheng, Xiang: "Polyphenol- and Caffeine-Rich Postfermented Pu-erh Tea Improves Diet-Induced Metabolic Syndrome by Remodeling Intestinal Homeostasis in Mice." in: Infection and immunity, Vol. 86, Issue 1, (2017) (PubMed).

  • Target Alle OLR1 ELISA Kits anzeigen

    OLR1 (Oxidized Low Density Lipoprotein (Lectin-Like) Receptor 1 (OLR1))

    Andere Bezeichnung

    OLR1

    Hintergrund

    Background: LOX-1 (lectin-type oxidized LDL receptor 1) also known as OLR1, is a protein that in humans is encoded by the OLR1 gene. LOX-1 is a receptor protein which belongs to the C-type lectin superfamily. The LOX1 gene is mapped to 12p13-p12 by fluorescence in situ hybridization. LOX1 is expressed on the plasma membrane of differentiated macrophages, but not on monocytes. The LOX1 protein acts as a macrophage scavenger receptor. LOX1 expression was detected in all choroidal neovascular membranes, regardless of structure, whereas there was no evidence of LOX1 within the posterior segments of normal eyes. LOX1 plays an active role in the pathogenesis of choroidal neovascularization, especially in ARMD.

    Gene Full Name: oxidized low density lipoprotein receptor 1

    Gen-ID

    4973

    UniProt

    P78380