PROS1 ELISA Kit

PROS Reaktivität: Human Colorimetric Competition ELISA Plasma, Serum
Produktnummer ABIN1440255
  • Target Alle PROS1 (PROS) ELISA Kits anzeigen
    PROS1 (PROS) (Protein S (PROS))
    Reaktivität
    • 5
    • 3
    • 3
    • 3
    • 3
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    Human
    Nachweismethode
    Colorimetric
    Methodentyp
    Competition ELISA
    Untere Nachweisgrenze
    0.25 µg/mL
    Applikation
    ELISA
    Verwendungszweck
    The AssayMax Human Protein S ELISA (Enzyme-Linked Immunosorbent Assay) kit is designed for detection of human protein S in plasma and serum. This assay employs a quantitative competitive enzyme immunoassay technique that measures human protein S in less than 3 hours. A polyclonal antibody specific for human protein S has been pre-coated onto a 96-well microplate with removable strips. Protein S in standards and samples is competed by a biotinylated protein S sandwiched by the immobilized antibody and streptavidin-peroxidase conjugate. All unbound material is then washed away and a peroxidase enzyme substrate is added. The color development is stopped and the intensity of the color is measured.
    Marke
    AssayMax
    Proben
    Serum, Plasma
    Analytische Methode
    Quantitative
    Kreuzreaktivität (Details)
    Cross-Reactivity: Canine > 90%, Bovine 10%, Monkey 50%, Mouse 10%, Rat 50%, Swine 10%
    Produktmerkmale
    Standard Added Value: 0.3 - 3 ug/mL
    Bestandteile
    Human Protein S Microplate: A 96-well polystyrene microplate (12 strips of 8 wells) coated with a polyclonal antibody against human protein S. 2
    Sealing Tapes: Each kit contains 3 pre-cut, pressure-sensitive sealing tapes that can be cut to fit the format of the individual assay.
    Human Protein S Standard: Human Protein S in a buffered protein base (8 µg, lyophilized).
    Biotinylated Protein S: 1 vial, lyophilized.
    EIA Diluent Concentrate (10x): A 10-fold concentrated buffered protein base (20 mL).
    Wash Buffer Concentrate (20x): A 20-fold concentrated buffered surfactant (30 mL).
    Streptavidin-Peroxidase Conjugate (SP Conjugate): A 100-fold concentrate (80 µL).
    Chromogen Substrate: A ready-to-use stabilized peroxidase chromogen substrate tetramethylbenzidine (8 mL).
    Stop Solution: A 0.5 N hydrochloric acid to stop the chromogen substrate reaction (12 mL).
    Benötigtes Material
    Microplate reader capable of measuring absorbance at 450 nm.
    Pipettes (1-20 µL, 20-200 µL, 200-1000 µL and multiple channel).
    Deionized or distilled reagent grade water.
    Featured
    Zu unserem meistverkauften PROS ELISA Kit
    Top Product
    Discover our top product PROS ELISA Kit
  • Kommentare

    Total Protein S

    Testdauer
    < 3 h
    Plattentyp
    Pre-coated
    Aufbereitung der Reagenzien

    Freshly dilute all reagents and bring all reagents to room temperature before use.
    EIA Diluent Concentrate (10x): If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved. Dilute the EIA Diluent 1:10 with reagent grade water. Store for up to 1 month at 2-8°C.
    Standard Curve: Reconstitute the 8 µg of Protein S Standard with 1 mL of EIA Diluent to generate a stock solution of 8 µg/mL. Allow the standard to sit for 10 minutes with gentle agitation prior to making dilutions. Prepare duplicate or triplicate standard points by serially diluting the stock solution (8 µg/mL) 1:2 with EIA Diluent to produce 4, 2, 1, 0.5, and 0.25 µg/mL solutions. EIA 3 Diluent serves as the zero standard (0 µg/mL). Any remaining solution should be frozen at -20°C and used within 30 days.
    Biotinylated Protein S (2x): Dilute Biotinylated protein S with 4 mL EIA Diluent to produce a 2-fold stock solution. Allow the biotin to sit for 10 minutes with gentle agitation prior to making dilutions. The stock solution should be further diluted 1:2 with EIA Diluent. Any remaining solution should be frozen at -20°C and used within 30 days.
    Wash Buffer Concentrate (20x): If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved. Dilute the Wash Buffer Concentrate 1:20 with reagent grade water.
    SP Conjugate (100x): Spin down the SP Conjugate briefly and dilute the desired amount of the conjugate 1:100 with EIA Diluent. Any remaining solution should be frozen at -20°C.

    Aufbereitung der Proben

    Plasma: Collect plasma using one-tenth volume of 0.1 M sodium citrate as an anticoagulant. Centrifuge samples at 2000 x g for 10 minutes and assay. Dilute samples 1:10 into EIA Diluent. The undiluted samples can be stored at <-20°C for up to 3 months. Avoid repeated freeze-thaw cycles. (EDTA or Heparin can also be used as anticoagulant.)
    Serum: Samples should be collected into a serum separator tube. After clot formation, centrifuge samples at 2000 x g for 10 minutes. Remove serum and assay. Dilute samples 1:10 into EIA Diluent. The undiluted samples can be stored at <-20°C for up to 3 months. Avoid repeated freeze- thaw cycles.

    Testdurchführung

    Prepare all reagents, working standards and samples as instructed. Bring all reagents to room temperature before use. The assay is performed at room temperature (20-30°C).
    Remove excess microplate strips from the plate frame and return them immediately to the foil pouch with desiccant inside. Reseal the pouch securely to minimize exposure to water vapor and store in a vacuum desiccator.
    Add 25 µL of standard or sample per well, and immediately add 25 µL of Biotinylated Protein S to each well (on top of the Standard or sample) and mix gently. Cover wells with a sealing tape and incubate for two hours. Start the timer after the last sample addition.
    Wash five times with 200 µL of Wash Buffer manually. Invert the plate each time and decant the contents, hit it 4-5 times on absorbent paper towel to completely remove the liquid. If using a machine wash six times with 300 µL of Wash Buffer and then invert the plate, decant the contents, hit it 4-5 times on absorbent paper towel to completely remove the liquid.
    Add 50 µL of Streptavidin-Peroxidase Conjugate to each well and incubate for 30 minutes. Turn on the microplate reader and set up the program in advance.
    Wash the microplate as described above.
    Add 50 µL of Chromogen Substrate per well and incubate for about 10 minutes or till the optimal blue color density develops. Gently tap plate to ensure thorough mixing and break the bubbles in the well with pipette tip.
    Add 50 µL of Stop Solution to each well. The color will change from blue to yellow.
    Read the absorbance on a microplate reader at a wavelength of 450 nm immediately. If wavelength correction is available, subtract readings at 570 nm from those at 450 nm to correct optical imperfections. Otherwise, read the plate at 450 nm only. Please note that some unstable black particles may be generated at high concentration points after stopping the reaction for about 10 minutes, which will reduce the readings.

    Ergebnisberechnung

    Calculate the mean value of the duplicate or triplicate readings for each standard and sample.
    To generate a Standard Curve, plot the graph using the standard concentrations on the x-axis and the corresponding mean 450 nm absorbance on the y-axis. The best-fit line can be determined by regression analysis using log-log or four-parameter logistic curve-fit.
    Determine the unknown sample concentration from the Standard Curve and multiply the value by the dilution factor.

    Testpräzision
    Intra-assay and inter-assay coefficients of variation were 4.9 % and 7.5 % respectively.
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Handhabung
    Prepare all reagents (working diluent buffer, wash buffer, standards, biotinylated-protein, and SP conjugate) as instructed, prior to running the assay.
    Prepare all samples prior to running the assay. The dilution factors for the samples are suggested in this protocol. However, the user should determine the optimal dilution factor.
    Spin down the SP conjugate vial before opening and using contents.
    The kit should not be used beyond the expiration date.
    The Stop Solution is an acid solution
    Lagerung
    4 °C/-20 °C
    Informationen zur Lagerung
    Store components of the kit at 2-8°C or -20°C upon arrival up to the expiration date.
    Store SP Conjugate at -20°C
    Store Microplate, Diluent Concentrate (10x), Wash Buffer, Stop Solution, and Chromogen Substrate at 2-8°C
    Opened unused microplate wells may be returned to the foil pouch with the desiccant packs. Reseal along zip-seal. May be stored for up to 1 month in a vacuum desiccator.
    Diluent (1x) may be stored for up to 1 month at 2-8°C.
    Store Standard and Biotinylated Protein at 2-8°C before reconstituting with Diluent and at -20°C after reconstituting with Diluent.
  • Target Alle PROS1 (PROS) ELISA Kits anzeigen
    PROS1 (PROS) (Protein S (PROS))
    Andere Bezeichnung
    Proteins (PROS Produkte)
    Synonyme
    PROS ELISA Kit, PS21 ELISA Kit, PS22 ELISA Kit, PS23 ELISA Kit, PS24 ELISA Kit, PS25 ELISA Kit, PSA ELISA Kit, THPH5 ELISA Kit, THPH6 ELISA Kit, zgc:154001 ELISA Kit, AW214361 ELISA Kit, protein S ELISA Kit, protein S (alpha) ELISA Kit, PROS1 ELISA Kit, Pros1 ELISA Kit, pros1 ELISA Kit
    Hintergrund
    Protein S is a single-chain vitamin K-dependent plasma glycoprotein consisting of 635 amino acids with a molecular weight of about 70 kDa. It functions as a cofactor for the anticoagulant activated protein C to inhibit blood coagulation. In plasma, it is both in a free cofactor active form and in an inactive form complexed with C4b-binding protein (C4BP). The complex acts as a bridge between coagulation and inflammation due to the involvement of C4BP in regulating complement activation. Hereditary protein S deficiency causes recurrent venous thrombosis. Acquired protein S deficiency is associated with nephrotic syndrome, disseminated intravascular coagulation, liver disease and the use of oral anticoagulants, leading to increased thrombotic risk.