CST3 ELISA Kit
Kurzübersicht für CST3 ELISA Kit (ABIN1112585)
Target
Alle CST3 ELISA Kits anzeigenReaktivität
Nachweismethode
Methodentyp
Detektionsbereich
Applikation
Proben
-
-
Untere Nachweisgrenze
- 312 pg/mL
-
Verwendungszweck
- For quantitative detection of Cystain C in human serum, plasma, body fluids, tissue lysates or cell culture supernatants.
-
Analytische Methode
- Quantitative
-
Sensitivität
- < 10 pg/mL
-
Bestandteile
- 1. One 96-well plate pre-coated with anti-Human Cystatin C antibody 2. Lyophilized Human Cystatin C standards: 2 tubes (20ng / tube) 3. Sample / Standard diluent buffer: 30ml 4. Biotin conjugated anti-Human Cystatin C antibody (Concentrated): 130 µl.
-
Benötigtes Material
- 1. 37 °C incubator 2. Microplate reader (wavelength: 450nm) 3. Precise pipette and disposable pipette tips 4. Automated plate washer 5. ELISA shaker 6. 1.5ml of Eppendorf tubes 7. Plate cover 8. Absorbent filter papers 9. Plastic or glass container with volume of above 1L
-
-
-
-
Kommentare
-
This kit was based on sandwich enzyme-linked immune-sorbent assay technology. Anti-Cystatin C polyclonal antibody was pre-coated onto 96-well plates. And the biotin conjugated anti-Cystatin C polyclonal antibody was used as detection antibodies. The standards test samples and biotin conjugated detection antibody were added - the wells subsequently and wash with wash buffer. Avidin-Biotin-Peroxidase Complex was added and unbound conjugates were washed away with wash buffer. TMB substrates were used - visualize HRP enzymatic reaction. TMB was catalyzed by HRP - produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional - the Cystatin C amount of sample captured in plate. Read the O.D. absorbance at 450 nm in a microplate reader and then the concentration of Cystatin C can be calculated.
-
Plattentyp
- Pre-coated
-
Aufbereitung der Reagenzien
-
- Before the experiment, centrifuge each kit component for several minutes to bring down all reagents to the bottom of tubes. 2. It is recommend to measure each standard and sample in duplicate. 3. Do NOT let the plate completely dry at any time! Since the dry condition can inactivate the biological material on the plate. 4. Do not reuse pipette tips and tubes to avoid cross contamination. 5. Do not use the expired components and the components from different batches. 6. To avoid the marginal effect of plate incubation for temperature differences (the marginal wells always get stronger reaction), it is recommend to equilibrate the ABC working solution and TMB substrate for at least 30 min at room temperature (37°C ) before adding to wells.The TMB substrate (Kit Component 8) is colorless and transparent before use, if not, please contact us for replacement.
-
Aufbereitung der Proben
-
Preparation of sample and reagents 1. Sample Isolate the test samples soon after collecting, then, analyze immediately (within 2 hours). Or aliquot and store at -20 °C for long term. Avoid multiple freeze-thaw cycles.
Body fluids, tissue lysates and cell culture supernatants: Centrifuge to remove precipitate, analyze immediately or aliquot and store at -20 °C .
Serum: Coagulate the serum at room temperature (about 4 hours). Centrifuge at approximately 1000 × g for 15 min. Analyze the serum immediately or aliquot and store at -20 °C .
Plasma: Collect plasma with heparin or EDTA as the anticoagulant. Centrifuge for 15 min at 1000 x g within 30 min of collection. Analyze immediately or aliquot and store frozen at -20 °C. Citrate can not be used as anticoagulant here. Note: 1. Coagulate blood samples completely, then, centrifuge, and avoid hemolysis and particle. 2. NaN3 can not be used as test sample preservative, since it is the inhibitor for HRP. -
Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
-
-
Konservierungsmittel
- Sodium azide, Thimerosal (Merthiolate)
-
-
- CST3 (Cystatin C (CST3))
-
Andere Bezeichnung
- Cystatin C
-
Hintergrund
- Cystatin C or cystatin 3, a protein encoded by the CST3 gene, is mainly used as a biomarker of kidney function. It is a single 120-residue polypeptide with a molecular mass of approximately 13.26 kD. Cystatin C plays a role in network reorganization in the epileptic dentate gyrus, especially in granule cell dispersion and guidance of migrating newborn granule cells. It is an alternative measure of kidney function that may have prognostic importance among elderly persons who do not meet standard criteria for chronic kidney disease. Among elderly persons without chronic kidney disease, cystatin C is a prognostic biomarker of risk for death, cardiovascular disease, and chronic kidney disease, thereby signaling a state of 'preclinical' kidney dysfunction.
Target Alle CST3 ELISA Kits anzeigen
-