In den Warenkorb
Bestellen Sie auch über:
+49 (0)241 95 163 153
+49 (0)241 95 163 155

Glucagon (GCG) ELISA Kit

Antigen

Glucagon (GCG)

Synonyme GGR, FLJ97182, MGC138246, GLP1, GLP2, GRPP, GLP-1, GCG, Gcg
Reaktivität
Alternativen: Human (9), Ratte (Rattus) (9), Maus (8), Schwein (5), Huhn (4), Affe (3), Rind (Kuh) (2), Cynomolgus (2), Meerschweinchen (2), Kaninchen (2), Hund (1), Schaf (1)
Applikation
ELISA
Zertifikate ISO 9001:2008
Produktnummer ABIN367664
Menge 96 Tests
Preis 711,26 €   Zzgl. Versandkosten €20,00 und MWSt
Lieferung nach
Verfügbarkeit Lieferung in 7 bis 10 Werktagen

Produktbeschreibung

Produktmerkmale This immunoassay kit allows for the in vitro quantitative determination of mouse GLP-1 concentrations in cell culture supernates, serum, plasma and other biological fluids. 
Weitere Bezeichnung glucagon-like peptide-1 (GLP-1)
Proben Serum, Plasma
Beschreibung Glucagon Like Peptide-1 (GLP-1) is a peptide hormone from the intestinal mucosa, which is produced from its precursor, proglucagon by post transnational processing. The mammalian proglucagon is synthesized in the neuroendocrine L-cell of the intestine and the alpha-cells of the pancreas. It contains within its structure the sequences of glucagon and two glucagon-like peptides (GLP-1 and GLP-2) in tandem flanked at their amino and carboxyl termini by dibasic residues. GLP-1 is a 37 amino acids peptide and produced in the small intestine and in the pancreas in the rat, in either C-terminal-amidated on glycine-extended form. GLP1 (7-36) amide and its receptor are present in several brain regions and may play a role in the physiological control of feeding. Several reports have been presented as follows as to the biological activities of GLP-1. GLP-1 (7-37) and (7-36) amide is known as one of the most potent insulin secretagogues.
Spezifität This assay recognizes recombinant and natural mouse GLP-1. No significant cross-reactivity or interference was observed.
Sensitivität The minimum detectable dose of mouse GLP-1 is typically less than 0.08 pg/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. Detection Range: The minimum detectable dose of mouse GLP-1 is typically less than 0.08 pg/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero.

Anwendungen

Prinzip The microtiter plate provided in this kit has been pre-coated with an antibody specific to GLP-1. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific for GLP-1 and Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB (3,3',5,5' tetramethyl-benzidine) substrate solution is added to each well. Only those wells that contain GLP-1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of GLP-1 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Protokoll Reagent Preparation:
Bring all reagents to room temperature before use. 1. Wash Buffer If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 500 ml of Wash Buffer. 2. Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 ml of Sample Diluent. This reconstitution produces a stock solution of 20 pg/ml. Allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making serial dilutions. The undiluted standard serves as the high standard (20 pg/ml). The Sample Diluent serves as the zero standard (0 pg/ml). Prepare fresh for each assay. Use within 4 hours and discard after use. 3. Biotin-antibody Centrifuge the vial before opening. Dilute to the working concentration using Biotin-antibody Diluent(1:100), respectively. 4. HRP-avidin Centrifuge the vial before opening. Dilute to the working concentration using HRP-avidin Diluent(1:100), respectively. Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
Assay Procedure:
Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate. All the reagents should be added directly to the liquid level in the well. The pipette should avoid contacting the inner wall of the well. 1. Recommend to dilute the serum or plasma samples with Sample Diluent(1:200) before test. The suggested 200-fold dilution can be achieved by adding 10 µ l sample to 190 µ l of Sample Diluent. Complete the 200-fold dilution by adding 25 µ l of this solution to 225 µ l of Sample Diluent. The recommended dilution factor is for reference only. The optimal dilution factor should be determined by users according to their particular experiments. 2. Add 100 µ l of Standard, Blank, or Sample per well. Cover with the adhesive strip. Incubate for 2 hours at 37°C. 3. Remove the liquid of each well, don’t wash. 4. Add 100 µ l of Biotin-antibody working solution to each well. Incubate for 1 hour at 37°C. Biotin-antibody working solution may appear cloudy. Warm up to room temperature and mix gently until solution appears uniform. 5. Aspirate each well and wash, repeating the process three times for a total of three washes. Wash: Fill each well with Wash Buffer (200 µ l) and let it stand for 2 minutes, then remove the liquid by flicking the plate over a sink. The remaining drops are removed by patting the plate on a paper towel. Complete removal of liquid at each step is essential to good performance. 6. Add 100 µ l of HRP-avidin working solution to each well. Cover the microtiter plate with a new adhesive strip. Incubate for 1 hour at 37°C. 7. Repeat the aspiration and wash five times as step 4. 8. Add 90 µ l of TMB Substrate to each well. Incubate for 10-30 minutes at 37°C. Keeping the plate away from drafts and other temperature fluctuations in the dark. 9. Add 50 µ l of Stop Solution to each well when the first four wells containing the highest concentration of standards develop obvious blue color. If color change does not appear uniform, gently tap the plate to ensure thorough mixing. 10. Determine the optical density of each well within 30 minutes, using a microplate reader set to 450 nm.
Calculation of Results:
Using the professional soft ",Curve Exert 1.3", to make a standard curve is recommended, which can be downloaded from our web. Average the duplicate readings for each standard, control, and sample and subtract the average zero standard optical density. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the y-axis against the concentration on the x-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the GLP-1 concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.
Limitations of the Procedure:
The kit should not be used beyond the expiration date on the kit label. Do not mix or substitute reagents with those from other lots or sources. It is important that the Standard Diluent selected for the standard curve be consistent with the samples being assayed. If samples generate values higher than the highest standard, dilute the samples with the appropriate Standard Diluent and repeat the assay. Any variation in Standard Diluent, operator, pipetting technique, washing technique, incubation time or temperature, and kit age can cause variation in binding. This assay is designed to eliminate interference by soluble receptors, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
Sample collection and storage:
Serum Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 g. Remove serum and assay immediately or aliquot and store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles. Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of collection. Assay immediately or aliquot and store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles. Note: Grossly hemolyzed samples are not suitable for use in this assay.
Testdurchführung Assay Time: 1-3h
Sample Volume: 50-100ul
Applikationshinweise Detection Wavelength: 450 nm
Bestandteile Reagent (Quantity): Assay plate (1), Standard (2), Sample Diluent (2x20ml), Biotin-antibody Diluent (1x10ml), HRP-avidin Diluent (1x10ml), Biotin-antibody (1x120 µl), HRP-avidin (1x120µl), Wash Buffer (25×concentrate) (1x20ml), TMB Substrate (1x10ml), Stop Solution (1x10ml)
Benötigtes Material Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm. Pipettes and pipette tips. Deionized or distilled water. Squirt bottle, manifold dispenser, or automated microplate washer. An incubator which can provide stable incubation conditions up to 37°C±0.5°C.
Lagerung 1. Unopened test kits should be stored at 2-8 ° C upon receipt and the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit, provided it is stored as prescribed above. Refer to the package label for the expiration date. 2. Opened test plate should be stored at 2-8 ° C in the aluminum foil bag with desiccants to minimize exposure to damp air. The kits will remain stable until the expiring date shown, provided it is stored as prescribed above. 3. A microtiter plate reader with a bandwidth of 10 nm or less and an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
Forschungsgebiet Hormone
Beschränkungen Nur für Forschungszwecke einsetzbar

Alternativen

Alternativen zu Antigen "Glucagon (GCG)", Typ "Kits" finden
Reaktivitäten Human (9), Ratte (Rattus) (9), Maus (8), Schwein (5), Huhn (4), Affe (3), Rind (Kuh) (2), Cynomolgus (2), Meerschweinchen (2), Kaninchen (2), Hund (1), Schaf (1)