Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

IL-9 ELISA Kit

IL9 Reaktivität: Maus Colorimetric Sandwich ELISA 0.1-60 ng/mL Cell Culture Supernatant, Plasma, Serum
Produktnummer ABIN625153
  • Target Alle IL-9 (IL9) ELISA Kits anzeigen
    IL-9 (IL9) (Interleukin 9 (IL9))
    Reaktivität
    • 5
    • 4
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Maus
    Nachweismethode
    Colorimetric
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    0.1-60 ng/mL
    Untere Nachweisgrenze
    0.1 ng/mL
    Applikation
    ELISA
    Verwendungszweck
    Mouse IL-9 ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Proben
    Serum, Plasma, Cell Culture Supernatant
    Analytische Methode
    Quantitative
    Spezifität
    This ELISA kit shows no cross-reactivity with any of the cytokines tested: Mouse CD30, L CD30, T CD40, CRG-2, CTACK, CXCL16, Eotaxin , Eotaxin-2, Fas Ligand, Fractalkine, GCSF, GM-CFS, IFN- gamma, IGFBP-3, IGFBP-5, IGFBP-6, IL-1 alpha, IL-1 beta, IL-2, IL-3, IL-3 Rb, IL-4, IL-5, IL-10, IL-12 p40/p70, IL-12 p70, IL-13, IL-17, KC, Leptin R, LEPTIN(OB), LIX, L-Selectin, Lymphotactin, MCP-1, MCP-5, M-CSF, MIG, MIP-1 alpha, MIP-1 gamma, MIP-2, MIP-3 beta, MIP-3 alpha, PF-4, P-Selectin, RANTES, SCF, SDF-1 alpha, TARC, TCA-3, TECK, TIMP-1, TNF-alpha, TNF RI, TNF RII, TPO, VCAM-1, VEGF.
    Sensitivität
    100 pg/mL
    Produktmerkmale
    • Strip plates and additional reagents allow for use in multiple experiments
    • Quantitative protein detection
    • Establishes normal range
    • The best products for confirmation of antibody array data
    Bestandteile
    • Pre-Coated 96-well Strip Microplate
    • Wash Buffer
    • Stop Solution
    • Assay Diluent(s)
    • Lyophilized Standard
    • Biotinylated Detection Antibody
    • Streptavidin-Conjugated HRP
    • TMB One-Step Substrate
    Benötigtes Material
    • Distilled or deionized water
    • Precision pipettes to deliver 2 μL to 1 μL volumes
    • Adjustable 1-25 μL pipettes for reagent preparation
    • 100 μL and 1 liter graduated cylinders
    • Tubes to prepare standard and sample dilutions
    • Absorbent paper
    • Microplate reader capable of measuring absorbance at 450nm
    • Log-log graph paper or computer and software for ELISA data analysis
    Featured
    Zu unserem meistverkauften IL9 ELISA Kit
    Top Product
    Discover our top product IL9 ELISA Kit
  • Applikationshinweise
    Recommended Dilution for serum and plasma samples2 fold
    Probenmenge
    100 μL
    Plattentyp
    Pre-coated
    Protokoll
    1. Prepare all reagents, samples and standards as instructed in the manual.
    2. Add 100 μL of standard or sample to each well.
    3. Incubate 2.5 h at RT or O/N at 4 °C.
    4. Add 100 μL of prepared biotin antibody to each well.
    5. Incubate 1 h at RT.
    6. Add 100 μL of prepared Streptavidin solution to each well.
    7. Incubate 45 min at RT.
    8. Add 100 μL of TMB One-Step Substrate Reagent to each well.
    9. Incubate 30 min at RT.
    10. Add 50 μL of Stop Solution to each well.
    11. Read at 450 nm immediately.
    Aufbereitung der Reagenzien
    1. Bring all reagents and samples to room temperature (18 - 25 °C) before use.
      2. Sample dilution: If your samples need to be diluted, Assay Diluent A (Item D) should be used for dilution of serum/plasma samples. 1x Assay Diluent B (Item E) should be used for dilution of culture supernatants. Suggested dilution for normal serum/plasma: 2 fold. Please note that levels of the target protein may vary between different specimens. Optimal dilution factors for each sample must be determined by the investigator.
      3. Assay Diluent B should be diluted 5-fold with deionized or distilled water.
      4. Preparation of standard: Briefly spin the vial of Item C and then add 400 µL Assay Diluent A (for serum/plasma samples) or 1x Assay Diluent B (for cell culture medium) into Item C vial to prepare a 100 ng/mL standard. Dissolve the powder thoroughly by a gentle mix. Add 260 µL IL-9 standard from the vial of Item C, into a tube with 173.3 µL Assay Diluent A or 1x Assay Diluent B to prepare a 60 ng/mL stock standard solution. Pipette 400 µL Assay Diluent A or 1x Assay Diluent B into each tube. Use the stock standard solution to produce a dilution series . Mix each tube thoroughly before the next transfer. Assay Diluent A or 1x Assay Diluent B serves as the zero standard (0 ng/mL). 200 µL 260 µL standard + 173.3 µL 200myl 200 µL 200 µL 200 µL 200 µL 60 20 6.667 2.222 0.741 0.247 0.0823 0 ng/mL ng/mL ng/mL ng/mL ng/mL ng/mL ng/mL ng/mL
      5. If the Wash Concentrate (20x) (Item B) contains visible crystals, warm to room temperature and mix gently until dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to yield 400 ml of 1x Wash Buffer.
      6. Briefly spin the Detection Antibody vial (Item F) before use. Add 100 µL of 1x Assay Diluent B into the vial to prepare a detection antibody concentrate. Pipette up and down to mix gently (the concentrate can be stored at 4 °C for 5 days). The detection antibody concentrate should be diluted 80-fold with 1x Assay Diluent B and used in step 4 of Part VI Assay Procedure.
      7. Briefly spin the HRP-Streptavidin concentrate vial (Item G) before use. HRP-Streptavidin concentrate should be diluted 1400-fold with 1x Assay Diluent B. For example: Briefly spin the vial (Item G) and pipette up and down to mix gently . Add 10 µL of HRP-Streptavidin concentrate into a tube with 14 ml 1x Assay Diluent B to prepare a 1400-fold diluted HRP- Streptavidin solution (don't store the diluted solution for next day use). Mix well.
    Testdurchführung
    1. Bring all reagents and samples to room temperature (18 - 25 °C) before use. It is recommended that all standards and samples be run at least in duplicate.
      2. Add 100 µL of each standard (see Reagent Preparation step 2) and sample into appropriate wells. Cover well and incubate for 2.5 hours at room temperature or over night at 4 °C with gentle shaking.
      3. Discard the solution and wash 4 times with 1x Wash Solution. Wash by filling each well with Wash Buffer (300 myl) using a multi-channel Pipette or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
      4. Add 100 µL of 1x prepared biotinylated antibody (Reagent Preparation step 6) to each well. Incubate for 1 hour at room temperature with gentle shaking.
      5. Discard the solution. Repeat the wash as in step
      6. Add 100 µL of prepared Streptavidin solution (see Reagent Preparation step 7) to each well. Incubate for 45 minutes at room temperature with gentle shaking.
      7. Discard the solution. Repeat the wash as in step
      8. Add 100 µL of TMB One-Step Substrate Reagent (Item H) to each well. Incubate for 30 minutes at room temperature in the dark with gentle shaking.
      9. Add 50 µL of Stop Solution (Item I) to each well. Read at 450 nm immediately.
    Ergebnisberechnung

    Calculate the mean absorbance for each set of duplicate standards, controls and samples, and subtract the average zero standard optical density. Plot the standard curve on log-log graph paper or using Sigma plot software, with standard concentration on the x-axis and absorbance on the y-axis. Draw the best-fit straight line through the standard points.
    Typical Data: These standard curves are for demonstration only. A standard curve must be run with each assay. . Assay Diluent A Mouse IL-9 concentration (ng/mL) 0.01 0.1 1 10 100 O D =4 50 n m 0.01 0.1 1 10 Assay Diluent B Mouse IL-9 concentration (ng/mL) 0.01 0.1 1 10 100 O D =4 50 n m 0.001 0.01 0.1 1 10
    Sensitivity: The minimum detectable dose of IL-9 is typically less than 0.1 ng/mL.
    Recovery: Recovery was determined by spiking various levels of mouse IL-9 into mouse serum, plasma and cell culture media. Mean recoveries are as follows: Sample Type Average % Recovery Range ( %) Serum 83.28 75-96 Plasma 82.16 74-95 Cell culture media 105.4 98-121
    Linearity: Sample Type Serum Plasma Cell Culture Media 1:2 Average % of Expected 86 85 90 Range ( %) 77-99 76-98 82-103 1:4 Average % of Expected 91 89 96 Range ( %) 80-102 79-101 85-106
    Reproducibility: Intra-Assay: CV<10 % Inter-Assay: CV<12 %

    Testpräzision
    Intra-Assay: CV< 10 % Inter-Assay: CV< 12 %
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Handhabung
    Avoid repeated freeze-thaw cycles.
    Lagerung
    -20 °C
    Informationen zur Lagerung
    The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.
    Haltbarkeit
    6 months
  • Cai, Zhang, Zhang, Chen, Hu: "Effect of Th9/IL-9 on the growth of gastric cancer in nude mice." in: OncoTargets and therapy, Vol. 12, pp. 2225-2234, (2019) (PubMed).

    Jimeno, Leceta, Martínez, Gutiérrez-Cañas, Pérez-García, Carrión, Gomariz, Juarranz: "Effect of VIP on the balance between cytokines and master regulators of activated helper T cells." in: Immunology and cell biology, Vol. 90, Issue 2, pp. 178-86, (2012) (PubMed).

    Komai-Koma, Gilchrist, McKenzie, Goodyear, Xu, Liew: "IL-33 activates B1 cells and exacerbates contact sensitivity." in: Journal of immunology (Baltimore, Md. : 1950), Vol. 186, Issue 4, pp. 2584-91, (2011) (PubMed).

  • Target Alle IL-9 (IL9) ELISA Kits anzeigen
    IL-9 (IL9) (Interleukin 9 (IL9))
    Andere Bezeichnung
    IL-9 (IL9 Produkte)
    Synonyme
    IL9 ELISA Kit, IL-9 ELISA Kit, Il-9 ELISA Kit, P40 ELISA Kit, HP40 ELISA Kit, interleukin 9 ELISA Kit, IL9 ELISA Kit, il9 ELISA Kit, Il9 ELISA Kit
    Hintergrund
    The Mouse IL-9 ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of mouse IL-9 in serum, plasma, cell culture supernatants and urine. This assay employs an antibody specific for mouse IL-9 coated on a 96-well plate. Standards and samples are pipetted into the wells and IL-9 present in a sample is bound to the wells by the immobilized antibody. The wells are washed and biotinylated anti-mouse IL-9 antibody is added. After washing away unbound biotinylated antibody, HRP-conjugated streptavidin is pipetted to the wells. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of IL-9 bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm. Reproducibility: Intra-Assay: CV<10% Inter-Assay: CV<12%.
    Gen-ID
    16198
    UniProt
    P15247
    Pathways
    JAK-STAT Signalweg
Sie sind hier:
Kundenservice