Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

FGF6 CLIA Kit

FGF6 Reaktivität: Ratte Chemiluminescent Sandwich ELISA 15.62 pg/mL - 1000 pg/mL Plasma, Serum
Produktnummer ABIN5654281
  • Target Alle FGF6 CLIA Kits anzeigen
    FGF6 (Fibroblast Growth Factor 6 (FGF6))
    Reaktivität
    • 4
    • 3
    • 3
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Ratte
    Nachweismethode
    Chemiluminescent
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    15.62 pg/mL - 1000 pg/mL
    Untere Nachweisgrenze
    15.62 pg/mL
    Applikation
    ELISA
    Proben
    Plasma, Serum
    Analytische Methode
    Quantitative
    Spezifität
    This assay has high sensitivity and excellent specificity for detection of Fibroblast Growth Factor 6 (FGF6). No significant cross-reactivity or interference between Fibroblast Growth Factor 6 (FGF6) and analogues was observed.
    Sensitivität
    0.59 pg/mL
    Top Product
    Discover our top product FGF6 ELISA Kit
  • Kommentare

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Testdauer
    2 - 3 h
    Plattentyp
    Pre-coated
    Protokoll
    The microplate provided in this kit has been pre-coated with an antibody specific to Fibroblast Growth Factor 6 (FGF6). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Fibroblast Growth Factor 6 (FGF6). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Fibroblast Growth Factor 6 (FGF6) level in the sample or standard.,
    Testpräzision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fibroblast Growth Factor 6 (FGF6) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fibroblast Growth Factor 6 (FGF6) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Handhabung
    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
    Lagerung
    4 °C,-20 °C
    Informationen zur Lagerung
    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
    Haltbarkeit
    4-8 months
  • Target Alle FGF6 CLIA Kits anzeigen
    FGF6 (Fibroblast Growth Factor 6 (FGF6))
    Andere Bezeichnung
    Fibroblast Growth Factor 6 (FGF6 Produkte)
    Synonyme
    FGF6 CLIA Kit, hst2 CLIA Kit, fgf-6 CLIA Kit, hbgf-6 CLIA Kit, HBGF-6 CLIA Kit, HST2 CLIA Kit, Fgf-6 CLIA Kit, HSTF-2 CLIA Kit, fgf4 CLIA Kit, fgf6 CLIA Kit, fibroblast growth factor 6 CLIA Kit, fibroblast growth factor 6a CLIA Kit, FGF6 CLIA Kit, fgf6 CLIA Kit, Fgf6 CLIA Kit, fgf6a CLIA Kit
    Hintergrund

    Gene Name: Fibroblast Growth Factor 6

    Gene Aliases: HBGF6, HST2, HST2 Oncogene, Heparin Secretory-Transforming Protein 2, Heparin-Binding Growth Factor 6

    Gen-ID
    170700
    UniProt
    Q8R5L5
    Pathways
    RTK Signalweg, Fc-epsilon Rezeptor Signalübertragung, EGFR Signaling Pathway, Neurotrophin Signalübertragung
Sie sind hier:
Kundenservice