Prostate Specific Antigen CLIA Kit

PSA Reaktivität: Human Chemiluminescent Sandwich ELISA
Produktnummer ABIN504784
  • Target Alle Prostate Specific Antigen (PSA) CLIA Kits anzeigen
    Prostate Specific Antigen (PSA)
    Reaktivität
    • 6
    • 4
    • 4
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    Human
    Nachweismethode
    Chemiluminescent
    Methodentyp
    Sandwich ELISA
    Applikation
    ELISA
    Verwendungszweck
    Immunoenzymometric assay: The essential reagents required for an immunoenzymometric assay include high affinity and specificity antibodies (enzyme and immobilized), with different and distinct epitope recognition, in excess, and native antigen. In this procedure, the immobilization takes place during the assay at the surface of a microplate well through the interaction of streptavidin coated on the well and exogenously added biotinylated monoclonal anti-PSA antibody. Upon mixing monoclonal biotinylated antibody, the enzyme-labeled antibody and a serum containing the native antigen, reaction results between the native antigen and the antibodies, without competition or steric hindrance, to form a soluble sandwich complex.
    Analytische Methode
    Quantitative
    Produktmerkmale
    The Quantitative Determination of Total Prostrate Specific Antigen (tPSA) Concentration in Human Serum by a Microplate Chemiluminescence Immunoassay
    Featured
    Zu unserem meistverkauften PSA ELISA Kit
    Top Product
    Discover our top product PSA ELISA Kit
  • Applikationshinweise
    All products that contain human serum have been found to be non-reactive for Hepatitis B Surface Antigen, HIV 1&2 and HCV Antibodies by FDA required tests. Since no known test can offer complete assurance that infectious agents are absent, all human serum products should be handled as potentially hazardous and capable of transmitting disease. Good laboratory procedures for handling blood products can be found in the Center for Disease Control / National Institute of Health, "Biosafety in Microbiological and Biomedical Laboratories," 2nd Edition, 1988, HHS Publication No. (CDC) 88-8395.
    Probenmenge
    25 μL
    Plattentyp
    Pre-coated
    Protokoll

    Specimien Collection and Preparation:

    The specimens shall be blood serum in type and the usual precau_x001F_tions in the collection of venipuncture samples should be observed. The blood should be collected in a plain redtop venipuncture tube without additives. Allow the blood to clot. Centrifuge the specimen to separate the serum from the cells. Samples may be refrigerated at 2_x001E_8C for a maximum period of five (5) days. If the specimen(s) can not be assayed within this time, the sample(s) may be stored at temperatures of _x001E_20C for up to 30 days. Avoid repetitive freezing and thawing. When assayed in duplicate, 0.050ml of the specimen is re_x001F_quired.

    Reagent Preparation:

    1. Wash Buffer Dilute contents of Wash Concentrate to 1000ml with distilled or deionized water in a suitable storage container. Store diluted buffer at room temperature 20-27(C. 2. Working Signal Reagent Solution - Store at 2 - 8(C. Determine the amount of reagent needed and prepare by mixing equal portions of Signal Reagent A and Signal Reagent B in a clean container. For example, add 1 ml of A and 1ml of B per two (2) eight well strips (A slight excess of solution is made). Discard the unused portion if not used within 36 hours after mixing. If complete utilization of the reagents is anticipated, within the above time constraint, pour the contents of Signal Reagent B into Signal Reagent A and label accordingly.

    Test Procedure:

    Before proceeding with the assay, bring all reagents, serum references and controls to room temperature (20 - 27(C). 1. Format the microplates wells for each serum reference, control and patient specimen to be assayed in duplicate. Replace any unused microwell strips back into the aluminum bag, seal and store at 2-8(C. 2. Pipette 0.025 ml (25l) of the appropriate serum reference, con_x001F_trol or specimen into the assigned well. 3. Add 0.100 ml (100l) of the PSA Tracer Reagent to each well. It is very important to dispense all reagents close to the bottom of the coated well. 4. Swirl the microplate gently for 20-30 seconds to mix and cover. 5. Incubate 30 minutes at room temperature. 6. Discard the contents of the microplate by decantation or aspiration. If decanting, tap and blot the plate dry with absorbent paper. 7. Add 350l of wash buffer (see Reagent Preparation Section), decant (tap and blot) or aspirate. Repeat four (4) additional times for a total of five (5) washes. An automatic or manual plate washer can be used. Follow the manufacturers instruction for proper usage. If a squeeze bottle is employed, fill each well by depressing the container (avoiding air bubbles) to dispense the wash. Decant the wash and repeat four (4) additional times. Add 0.100 ml (100l) of working signal reagent solution to all wells (see Reagent Preparation Section). Always add reagents in the same order to minimize reaction time differences between wells. Incubate at room temperature for five (5) minutes in the dark. Read the relative light units in each well, for 0.2 1.0 seconds/ well, using a microplate luminometer. The results should be read within thirty (30) minutes of adding the substrate solution.
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Target Alle Prostate Specific Antigen (PSA) CLIA Kits anzeigen
    Prostate Specific Antigen (PSA)
    Abstract
    PSA Produkte
    Synonyme
    APS CLIA Kit, KLK2A1 CLIA Kit, PSA CLIA Kit, hK3 CLIA Kit, KLK3 CLIA Kit, Klk1c10l2 CLIA Kit, RSGK-50 CLIA Kit, RSKG-50 CLIA Kit, rGK-3 CLIA Kit, Kal-3 CLIA Kit, Kal3 CLIA Kit, Klk3 CLIA Kit, AAP-S CLIA Kit, MP100 CLIA Kit, Psa CLIA Kit, R74825 CLIA Kit, goku CLIA Kit, kallikrein related peptidase 3 CLIA Kit, kallikrein 3 CLIA Kit, kallikrein 1-related peptidase C3 CLIA Kit, kallikrein B, plasma 1 CLIA Kit, aminopeptidase puromycin sensitive CLIA Kit, KLK3 CLIA Kit, Klk1c3 CLIA Kit, Klkb1 CLIA Kit, Npepps CLIA Kit
    Hintergrund
    Prostate Specific Antigen (PSA) is a serine protease with chymotrypsin-like activity (1, 2). The protein is a single chain glycoprotein with a molecular weight of 28.4 kDA (3). PSA derives its name from the observation that it is a normal antigen of the prostrate but is not found in any other normal or malignant tissue. PSA is found in benign, malignant and metastatic prostrate cancer. Since prostate cancer is the second most prevalent form of male malignancy, the detection of elevated PSA levels plays an important role in the early diagnosis. Serum PSA levels have been found to be more useful than prostatic acid phosphatase (PAP) in the diagnosis and management of patients due to increased sensitivity and specificity (4). In this method, PSA calibrator, patient specimen or control is first added to a streptavidin coated well. Biotinylated monoclonal and enzyme labeled antibodies (directed against distinct and different epitopes of PSA) are added and the reactants mixed. Reaction between the various PSA antibodies and native PSA forms a sandwich complex that binds with the streptavidin coated to the well. After the completion of the required incubation period, the enzyme-PSA antibody bound conjugate is separated from the unbound enzyme-PSA conjugate by aspiration or decantation. The activity of the enzyme present on the surface of the well is quantitated by reaction with a suitable substrate to produce light (luminescence). The employment of several serum references of known prostate specific antigen (PSA) levels permits the construction of a dose response curve of activity and con_x001F_centration. From comparison to the dose response curve, an unknown specimen's activity can be correlated with PSA concentration.
    Pathways
    Komplementsystem
Sie sind hier:
Kundenservice